KEZHE Shanghai
Filter
Showing 91–110 of 110 results
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–6 / 12 (standard), up to 48 (customizable) |
| Final Absolute Vacuum | 30 mbar |
| Solvent Recovery | Integrated Condensation System |
| Vacuum Pump Flow Rate | 30 L/min |
| Cooling Circulator Range | 10 °C to Ambient |
| Programmable Temperature Profile | 6-step, 0–10 h per step |
| Vortex Agitation Speed | 0–250 rpm |
| Tail-tube Volumes | 0.3 / 1 / 3 mL |
| Heating Method | Selectable Metal Bath or Water Bath |
| Power Supply | 220–240 V, 50/60 Hz, Max 2200 W |
| Control Interface | PC-based Software with Audit Trail |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–48 positions (standard: 24) |
| Final Absolute Vacuum | 30 mbar |
| Condensate Recovery | Integrated |
| Heating Options | Metal Bath or Water Bath (selectable) |
| Programmable Stages | 6-step gradient temperature control (0–10 h per stage) |
| Rotational Speed | 0–250 rpm |
| Solvent Recovery Efficiency | >95% |
| Cooling Circulator Compatibility | 10 °C to ambient |
| Vacuum Pump Flow Rate | 30 L/min |
| Power Supply | 220–240 V, 50/60 Hz |
| Max Power Consumption | 2200 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–48 positions (6/12 standard, 24/48 optional) |
| Vacuum Range | 30 mbar to atmospheric pressure |
| Vortex Speed | 0–250 rpm |
| Cold Trap Condensation | Integrated |
| Solvent Recovery | Yes |
| Heating Options | Metal Bath or Water Bath (selectable) |
| Final Volume Precision | 0.3 / 1 / 3 mL tail-tube options |
| Power Supply | 220–240 V, 50/60 Hz, max 2200 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity Options | 80 mL, 100 mL, 120 mL, or 500 mL (120 mL standard) |
| Throughput | 16 or 36 samples (configurable) |
| Heating Platform Range | Ambient to 90 °C |
| Vacuum Range | 20 mbar to atmospheric pressure |
| Vortex Shaking Speed | 0–300 rpm |
| Programmable Temperature Profiles | Up to 9-step gradient control |
| Timer Range | 0–10 hours |
| Vacuum Pump Flow Rate | 30 L/min |
| Power Supply | 220–240 V, 50/60 Hz |
| Max. Power Consumption | 2200 W |
| Control Interface | Touchscreen LCD |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | VNH-300 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity per Channel | 250 mL |
| Final Volume Setpoint Range | 0–1 mL |
| Heating Method | Dry Block Heating |
| Number of Channels | 6 |
| Maximum Gas Flow per Channel | 10 L/min |
| Control Interface | Touchscreen HMI |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VNH-500 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ≤ 0.5 °C |
| Sample Capacity per Vial | 10–80 mL |
| Maximum Simultaneous Samples | 72 (customizable) |
| Gas Flow Rate | Up to 15 L/min (N₂ or inert gas) |
| Heating Method | Water Bath |
| Operating Modes | Manual / Method-Based / Timer-Based |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VNH-600 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Vessel Capacity Options | 80 mL, 100 mL, 120 mL, 500 mL (120 mL standard) |
| Sample Throughput | 6 / 24 / 48 positions |
| Compatible Tube Volume | 1.5–200 mL |
| Heating Method | Water Bath |
| Gas Source | Nitrogen or Inert Gas |
| Max Gas Flow Rate | 15 L/min |
| Endpoint Detection | Infrared-based Quantitative Termination |
| Gas Flow Control | Independent per-channel with on/off valve |
| Airflow Design | Vortex-shear gas delivery |
| Safety Features | Real-time overheat/overpressure/low-water-level alerts |
| Viewing Window | Triple-side optical-grade transparent acrylic |
| Illumination | Adjustable 4-color LED bath lighting |
| Condensation Prevention | High-capacity axial exhaust fan |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Forced-Flow Centrifugal TLC System |
| UV Wavelengths | 254 nm & 365 nm |
| UV Source | Dual-Band UV Lamp |
| Separation Capacity | 100 mg – 2 g per run |
| Rotational Speed Range | 100 – 1450 rpm |
| Plate Diameter | 245 mm |
| Adsorbent Layer Thickness Options | 1, 2, 3, 4, 6, 8 mm |
| Solvent Consumption | < 350 mL per separation |
| Reusable Plates | Yes |
| Gradient Elution Capability | On-line, programmable via manual valve control |
| Plate Preparation Included | Yes (with scraper & plate former) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | KH-CTLC-III |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Instrument Type | Forced-Flow Centrifugal TLC System |
| Wavelength Range | 190–700 nm |
| Light Source | Dual-Wavelength UV Lamp (254 nm & 365 nm) |
| Detection Mode | Full-Spectrum UV Absorbance Detection |
| Sample Loading Capacity | 100 mg – 2 g per run |
| Rotational Speed | 100–1450 rpm |
| TLC Plate Diameter | 245 mm |
| Plate Thickness Options | 1, 2, 3, 4, 6, 8 mm |
| Flow Rate Range | 0–20 mL/min |
| Fraction Collection | X-Y Robotic Fraction Collector (120 positions, 15 mm test tubes) |
| Medium-Pressure Column | 15 × 400 mm glass column |
| Max. Operating Pressure | 0–50 kgf/cm² (0–4.9 MPa) |
| Plate Spinning Mechanism | CNC-Machined Precision Rotating Platform |
| Pump Type | Stepper-Motor-Driven Constant-Flow Peristaltic Pump |
| Integrated Sample Filtration | In-line Cartridge Filter for Adsorption Mitigation |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-ZY10E |
| Instrument Type | Fluorescence Detector-Compatible Post-Column Derivatization System |
| Temperature Range | Ambient to 150 °C |
| Temperature Accuracy | ±0.25 °C |
| Temperature Resolution | ±0.1 °C |
| Derivatization Pump Flow Rate | 0–10 mL/min |
| Flow Repeatability | ±0.1% |
| Reaction Coil Length | 10 m |
| Reactor Configuration | Modular, Single or Dual Cartridge Options |
| Mixing Architecture | Sealed Continuous-Loop Multi-Directional Flow Reactor |
| Peak Broadening Reduction | Optimized via Low-Dispersion Reaction Core Design |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NicePlate-10 |
| Price Range | USD 1,400 – 2,800 |
| Dispensing Volume Range | 0–30 mL |
| Pump Speed | 0.1–600 rpm |
| Flow Rate | 0.006–2300 mL/min |
| Compatible Vessels | Petri Dishes (standard 90 mm diameter, up to 9 positions), Test Tubes, and Custom Open-Top Containers |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NicePlate-20 |
| Instrument Type | Fully Automatic Microbial Media Dispensing System |
| Dispensing Range | 1–1000 mL |
| Accuracy at 15 mL | ±1% |
| Throughput | 400 Petri Dishes/hour |
| Compatible Dish Diameters | Ø90 mm (standard), 55 mm, 35 mm, 70 mm |
| Adjustable Dish Height | 12–26 mm |
| Dispensing Interval | 1–10 sec |
| UV Lamp Output | 2.3 W @ 254 nm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NooneLost-2000 |
| Instrument Type | Fully Automated Colony Counter |
| Counting Speed | >400 Petri Dishes per Hour |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Semi-Automatic Colony Counter |
| Counting Speed | >400 samples/h |
| Country of Origin | Domestic (China) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriMaster-3500C1 |
| Application Level | Laboratory-grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Pump Pressure Rating | 300 bar |
| Flow Rate Range | 0–50 mL/min per pump |
| Flow Stability | ≤2% RSD |
| UV-Vis Detection Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Detector Light Source | Dual-lamp system (Deuterium + Tungsten) |
| Fraction Collection | 6-port switching valve (standard) |
| Auto-sampler Quantitative Loop | 3 mL |
| Gradient Capability | Binary high-pressure mixing |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ScalePuri-50 |
| Application Level | Pilot-Scale Laboratory |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Maximum Flow Rate | 0–200 mL/min |
| Flow Accuracy | ±2.0% |
| Pressure Rating | Up to 20 MPa |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU (at 254 nm) |
| Baseline Drift | 0.5 mAU (at 254 nm) |
| Detection Modes | Quadruple Wavelength Simultaneous Monitoring |
| Column Compatibility | Axial Compression Columns (DAC50, ID 10–50 mm) |
| Fraction Collection | Volume-, Peak-, Time-, or Threshold-Triggered |
| Software Compliance | 21 CFR Part 11 Ready, Audit Trail, Electronic Signatures, User & Role Management |
| Regulatory Alignment | Designed for GLP/GMP environments, supports IQ/OQ/PQ validation |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-I |
| Instrument Category | TLC Sample Spotter |
| Spotting Uniformity | < 0.2 mm |
| Maximum Plate Size | 200 mm × 200 mm |
| Spotting Mechanism | Capillary or Microsyringe-Based Manual Deposition |
| Plate Protection Feature | Non-penetrating Tip Design |
| Compliance | Designed for GLP-aligned manual sample preparation workflows |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TB-2 |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | TLC Scanner Accessory |
| Wavelength Range | 190–700 nm (multi-band selectable) |
| Calibration Wavelengths | UV 254 nm, UV 365 nm, and White Light |
| Plate Size Capacity | 50 × 50 mm to 200 × 200 mm |
| Adjustability | Horizontal Leveling ±0.1°, Width Adjustment Range: 50–220 mm |
| Construction | Anodized Aluminum Frame with Tempered Glass Doors & Stainless Steel Shelves |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TG-I |
| Price Range | USD 140–700 (FOB Shanghai) |
| Instrument Category | TLC Auxiliary Equipment |
| Cutting Platform Dimensions | 300 × 250 mm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TS-I |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | TLC Spray Applicator |
| Scanning Method | Linear (N/A for spray applicator) |
| Wavelength Range | Not Applicable (Non-Optical Device) |
| Light Source | Not Applicable |
| Wavelength Accuracy | Not Applicable |
| Wavelength Repeatability | Not Applicable |
| Scan Speed | Not Applicable |
| Air Pressure Range | 10–30 psi |
| Nozzle Orifice Diameter | 0.2 mm |
| Spray Distance | 50 cm |
| Construction Material | Full Stainless Steel |