| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | DDL301 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 190–900 nm |
| Detection Method | Photomultiplier Tube (PMT) |
| Light Source | High-Intensity Halogen Lamp |
| Evaporation Principle | Low-Temperature Nebulization & Drift Tube Evaporation |
| Compatibility | HPLC, UHPLC, and LC-MS Coupling |
| Detection Sensitivity | Mass-sensitive, independent of chromophore, fluorophore, or electrochemical activity |
| Gradient Compatibility | Fully compatible with gradient elution |
| Baseline Stability | High resistance to flow rate and temperature fluctuations |
| Physical Footprint | Compact benchtop design (W × D × H: 240 × 450 × 320 mm) |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| System Model | AA9800 |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 10 µL |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | AA9800 Plus |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 10 µL |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Model | Pump II |
| Origin | USA |
| Type | High-Pressure, Precision Constant Flow Pump |
| Construction | Stainless Steel Fluid Path (PEEK fittings optional) |
| Control Interface | RS-232 |
| Remote Operation | Yes |
| Dual Check Valve Design | Yes |
| Automatic Pressure Protection | High/Low Pressure Cut-off |
| Self-Cleaning Pump Head | Yes |
| Quick-Drain Valve | Yes |
| LED Display | Yes |
| Seal Replacement | Tool-Free, Modular |
| Continuous Duty Rating | Yes |
| Chromatography-Compatible Flow Stability | Yes |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Model | SeriesIII |
| Flow Rate Range | 0.01–100 mL/min (typical for preparative constant-flow pumps) |
| Pressure Rating | Up to 400 bar |
| Power Supply | 100/110 V or 220 V, 50/60 Hz |
| Interface | RS-232 |
| Pump Head | Sapphire-plated plunger with auto-cleaning mechanism |
| Pulse Damping | Patented low-dead-volume pulse damping technology |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | France |
| Model Series | PICLab 100 / 150 / 200 / 600 / 1000 |
| Instrument Type | Preparative SFC System |
| Detector Options | DAD, UV-Vis, Mass Spectrometer (MS) |
| Maximum Operating Pressure | 350 bar |
| CO₂ Flow Rate Range | 10–1000 mL/min |
| Application Modes | Analytical, Semi-Preparative (up to 100 g), and Preparative (gram-to-kilogram scale) |
| CO₂ Recycling Capability | Standard on PICLab 150 and above |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Model | Q-Grad |
| Pump Type | Quaternary High-Pressure Gradient Pump |
| Flow Range | 1 µL/min – 20 mL/min |
| Gradient Composition | Up to 4 Solvents, Independently Controlled |
| Mixing Architecture | High-Pressure Binary/Quaternary Blending (No Low-Pressure Mixer or Online Degasser Required) |
| Dead Volume | Minimized via Integrated Direct High-Pressure Mixing |
| Bubble-Free Operation | Achieved through Positive-Displacement Plunger Design and Solvent Compressibility Compensation |