LANENDE
Filter
Showing all 10 results
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Cryostat Microtome |
| Automation Level | Semi-Automatic |
| Section Thickness Range | 0–60 µm (with 0.5–5 µm incremental steps per range) |
| Specimen Vertical Travel | 50 mm |
| Specimen Horizontal Travel | 20 mm |
| Max Section Area | 55 × 45 mm |
| Specimen Orientation Adjustment | ±8° horizontal, ±8° vertical, 360° rotation |
| Knife Base Translation Range | ±25 mm front/back, ±25 mm left/right |
| Knife Angle Adjustment | 0–15° |
| Overall Dimensions | 500 × 480 × 280 mm |
| Compliance | Designed for GLP-compliant histopathology workflows |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Cryostat Microtome |
| Model | LD-4080 |
| Cooling System | Dual-Compressor with Five-Point Targeted Cooling |
| Operating Temperature Range | Cryohead: −50 °C, Cryostage: −45 °C, Cryoblade: −35 °C, Chamber: −25 °C ± 5 °C |
| Section Thickness Range | 0–100 µm (adjustable in 0.5 µm increments up to 6 µm |
| Minimum Graduation | 0.5 µm |
| Specimen Horizontal Travel | 25 mm |
| Specimen Vertical Travel | 60 mm |
| Trimming Range | 0–600 µm (10 µm increments) |
| Sectioning Angle Adjustment | ±10° |
| Sectioning Speed | Adjustable |
| Cryo-Positioning Stations | 12 |
| Power Supply | 220 V AC, 800 VA |
| Net Weight | 120 kg |
| Compliance | Designed for GLP-compliant histopathology workflows |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LD-4080 |
| Cutting Thickness Range | 0–100 µm (0.5 µm minimum increment) |
| Sample Horizontal Travel | 25 mm |
| Sample Vertical Travel | 60 mm |
| Sectioning Angle Adjustment | ±10° |
| Five-Point Refrigeration System (Cryotome Head | –50°C, Cryostage: –45°C, Cryoblade: –35°C, Chamber: –25°C ±5°C) |
| Rapid Cool-down | <10 min to operational cryo-state |
| Power Supply | 220 V, 800 VA |
| Net Weight | 120 kg |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD-D100 Intelligent |
| Frequency | 23 kHz (adaptive) |
| Display | 7-inch medical-grade capacitive touchscreen |
| Temperature Monitoring | Real-time sample temperature sensing with visual display |
| Cooling Interface | External chiller port for precise thermal control |
| Safety | Auto-fault detection and audible/visual alarm system |
| Power Control | Adjustable ultrasonic power output |
| Timing Control | Programmable sonication time and duty cycle (on/off interval) |
| Brand | LANENDE |
|---|---|
| Model | LD-D150 |
| Measurement Principle | Doppler ultrasonic velocity profiling |
| Communication Protocol | Modbus RTU over RS485 |
| Power Supply | Wide-range DC input (12–24 VDC) |
| Housing Material | PVC, IP68-rated |
| Dimensions | 250 × 70 × 30 mm (L × W × H) |
| Minimum Operational Water Depth | ≥15 cm |
| Sensor Type | Submersible dual-sensor module (ultrasonic transducer + piezoresistive pressure sensor + NTC temperature sensor) |
| Output | Real-time velocity (m/s), water depth (m), temperature (°C), and calculated flow rate (m³/h or m³/d) |
| Installation | Fixed-mount via stainless-steel base plate |
| Compliance | Designed for field-deployable hydrometric monitoring in open channels and large-diameter conduits |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD-DY10 |
| Instrument Category | Multi-Mycotoxin Rapid Quantitative Analyzer |
| Detection Principle | Fluorescent Lateral Flow Immunoassay (FLFIA) |
| Detection Channels | 6 independent quantitative channels |
| Fluorescence Excitation Wavelength | 365 nm |
| Detector | Silicon Photodiode |
| Sample Processing Time | ≤12 min (including extraction and assay) |
| Assay Time per Test Strip | <4 s |
| Repeatability (CV) | ≤0.8% |
| Stability (Drift) | ≤0.6% |
| Relative Standard Deviation (RSD) | ≤6% |
| Data Storage Capacity | ≥1,000,000 records |
| Operating Temperature | 5–40 °C |
| Humidity Range | 10–90% RH |
| Dimensions (W×D×H) | 300 × 240 × 125 mm |
| Net Weight | 1.7 kg |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz |
| DC Output | 12 V / 5 A |
| Rated Power | 40 W |
| Connectivity | Dual USB-A, USB-B, RJ45 Ethernet, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LD-GX02 |
| Optical Resolution | 4800 × 9600 dpi |
| Max Scanning Area (Reflective) | 355.6 mm × 215.9 mm |
| Min Pixel Size | 0.005 mm × 0.0026 mm |
| Scan Interface | USB 2.0 |
| Color Depth | 48-bit |
| Light Source | Dual Cold Cathode Fluorescent Lamp (CCFL) |
| Supported Formats | TIFF, JPEG |
| Software Features | Topological Analysis, Fractal Dimension (Box-Counting), Root Angle Quantification (Gravitropic & Horizontal), Color-Based Segmentation, Interactive Editing (Split/Merge/Reconnect), Cloud Data Sync, Dual-Language UI (English/Chinese), FDA 21 CFR Part 11–Ready Audit Trail |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | LD-JQ12 |
| Detection Limit | 1 mg/kg |
| Detection Range | 0–100 mg/kg |
| Absorbance Range | 0.000–4.000 A |
| Repeatability | ±0.1% (A) |
| Absorbance Repeatability Error | ≤0.003 A |
| Photometric Drift | ±0.002 A (3 min) |
| Absorbance Accuracy | ±2.0% |
| Linearity Error | ±1.0% |
| Processor | ARM Cortex-A7 RK3288 (4-core, 1.88 GHz) |
| Display | 7-inch capacitive touchscreen (Chinese UI) |
| Power Supply | DC 12 V (supports vehicle power & optional 6 Ah Li-ion battery) |
| Detection Channels | ≥12 independent optical channels |
| Connectivity | Ethernet, Wi-Fi, GPRS, USB 2.0 |
| Data Output | Thermal printer (embedded), QR code generation, cloud upload via regulatory platform |
| Compliance Support | Designed for routine QC in food safety labs operating under GB 5009.49–2023, ISO/IEC 17025-aligned workflows, and internal GLP procedures |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | LD-JSD-3 Smart |
| Instrument Type | Handheld |
| Measurement Accuracy | ±0.1 %F·S |
| Operating Temperature Range | 0–40 °C |
| Processor Architecture | ARM Cortex-M3 |
| Operating System | Android-based firmware |
| Connectivity | Wi-Fi, GPS, GPRS (optional), USB-C interface |
| Display | 3.5-inch color touchscreen |
| Data Storage Capacity | Up to 5 million records |
| Data Export Format | CSV/Excel-compatible |
| Power Interface | Standard USB-C charging |
| Sensor Output | Real-time penetrometer force (N) and depth (mm) |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD-SY20 |
| Price | USD 2,050 (FOB) |