LAUDA Scientific
Filter
Showing all 29 results
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA 200 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 240 × 76 mm |
| Sample Stage Load Capacity | 12 kg |
| Imaging Magnification | 6.5× Zoom Lens |
| Video Capture | USB 3.0 High-Speed Camera (up to 3300 fps, 1920 × 1200 px) |
| Light Source | Monochromatic Uniform LED (Software-Adjustable Intensity) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-C |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.1° |
| Surface/Interfacial Tension Measurement Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm (fixed) |
| Maximum Sample Size | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging System | High-resolution, low-distortion, high-speed industrial fixed-focus optical lens |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-L |
| Instrument Type | Portable Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 1×10⁻³–2×10³ mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Optical Magnification | 6.5× Zoom Lens |
| Sample Handling | Motorized Robotic Arm with Dual-Droplet Dispensing Unit |
| Maximum Sample Size | Unlimited by Geometry or Dimensions |
| Working Distance | Up to 25 mm (Non-Contact Measurement) |
| Customizable Sample Stage | Fully Tailored to Specimen Dimensions |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-M |
| Instrument Type | Portable Video-Based Optical Contact Angle Analyzer |
| Measurement Principle | Top-View Optical Imaging (Axial Illumination & Coaxial Imaging) |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (0–90°), ±0.5° (90–180° for axisymmetric droplets) |
| Contact Angle Resolution | 0.1° |
| Sample Stage Constraints | None (unlimited sample size, shape, weight, or topography) |
| Imaging System | High-resolution industrial fixed-focus lens |
| Max Image Resolution | 752 × 480 pixels |
| Frame Rate | Up to 60 fps |
| Field of View | 12 mm × 8 mm |
| Light Source | Monochromatic, uniform cold LED with software-controlled intensity |
| Dispensing Unit | Manual digital micrometer syringe drive |
| Dispensing Precision | 0.004 µL |
| Dispensing Accuracy | 0.01 µL |
| Dimensions (L×W×H) | 77 × 60 × 150 mm |
| Weight | 1.0 kg |
| Compliance | Designed for ISO 19403-2, ASTM D7334, and DIN EN 14212-compliant surface wettability assessment |
| Software Features | ACI (Area Contact Index) calculation, multi-droplet batch analysis, GLP-compliant audit trail logging (optional) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-M |
| Instrument Type | Portable Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (0–90°), ±0.5° (90–180° for axisymmetric droplets) |
| Contact Angle Resolution | 0.1° |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm (fixed base unit) |
| Maximum Sample Size | Unlimited |
| Sample Stage Load Capacity | Unlimited |
| Imaging System | High-resolution, low-distortion industrial fixed-focus lens |
| Max Resolution | 752 × 480 px |
| Frame Rate | Up to 60 fps |
| Field of View | 12 × 8 mm |
| Light Source | Monochromatic, uniform LED cold light source with software-controlled intensity |
| Dispensing Unit | Integrated manual digital micro-dosage system |
| Dispensing Precision | 0.004 µL |
| Accuracy | ±0.01 µL |
| Device Dimensions | 77 × 60 × 150 mm (L×W×H) |
| Weight | ~1 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-P |
| Instrument Type | Video-based Optical Contact Angle Analyzer (Top-View Configuration) |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.1° |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Imaging System | High-resolution, low-distortion industrial fixed-focus lens |
| Working Distance | Up to 25 mm |
| Sample Stage Dimensions | 100 × 100 mm (fixed base) |
| Measurement Cycle Time | ~1–2 seconds per droplet |
| Interface Options | TTL digital output, software API (TCP/IP or DLL-based) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA MOB-X |
| Instrument Type | Portable Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (0–90°), ±0.5° (90–180° for axisymmetric droplets) |
| Contact Angle Resolution | 0.1° |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm (fixed base) |
| Imaging System | High-resolution, low-distortion industrial fixed-focus optical lens with high-speed capture capability |
| Maximum Sample Size | Unlimited |
| Sample Stage Load Capacity | Unlimited |
| Measurement Geometry | Top-view (orthogonal overhead imaging) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA.MOB-M |
| Instrument Type | Portable Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Measurement Accuracy | ±0.1° |
| Angular Resolution | 0.01° |
| Image Magnification | 6.5× |
| Maximum Sample Dimensions | 77 × 60 × 150 mm |
| Sample Stage Load Capacity | Unlimited (no size or weight restriction) |
| Viewing Geometry | Top-View Imaging Configuration |
| Light Source | Monochromatic, Uniform LED Cold Light (Software-Adjustable Intensity) |
| Dispensing System | Integrated Manual Digital Microliter Dispenser |
| Device Dimensions (L×W×H) | 77 × 60 × 150 mm |
| Weight | 1.0 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100 B |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 100 mm (fixed) |
| Maximum Sample Size | ∞ × 290 × 76 mm (L × W × H) |
| Stage Load Capacity | 12 kg |
| Optical Zoom | 6.5× Motorized Zoom Lens |
| Light Source | Monochromatic, Uniform LED Cold Light (Software & Manual Intensity Control) |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Instrument Dimensions | 600 × 160 × 543 mm (L × W × H) |
| Weight | 19 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging Magnification | 6.5× Zoom Lens (±6 mm Focus Adjustment) |
| Video Frame Rate | Up to 170 fps @ 1920×1200 px (with optional high-speed camera) |
| Software | SurfaceMeter™ Professional Suite |
| Compliance | ASTM D7334, ISO 19403-2/-3/-4, ISO 21361, USP <1058>, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA 100 |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Dimensions (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Zoom | 6.5× Motorized Telecentric Lens |
| Imaging System | USB 3.0 High-Speed Camera (752 × 480 px, up to 87 fps) |
| Illumination | Adjustable Uniform LED Cold Light Source |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100B |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging System | 50 mm High-Resolution Low-Distortion Lens with USB3.0 High-Speed Camera (752 × 480 px, 87 fps) |
| Light Source | Adjustable High-Uniformity LED Cold Light |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100DARF |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm (fixed) |
| Maximum Sample Size | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Magnification | 6.5× Zoom Lens |
| Vertical Adhesion Force Resolution | 0.01 µN |
| Vertical Stage Positioning Accuracy | 0.05 µm |
| Vertical Stage Speed Range | 0.04–500 mm/min |
| Horizontal Retention Force Measurement | Centrifugal Stage (0–750 rpm, max 40 g, acceleration 1–100 rpm/s, speed control accuracy ±2 rpm) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100M2 |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 240 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging Magnification | 45× Zoom Lens |
| High-Speed Camera | USB 3.0, 1920 × 1200 px, up to 3300 fps |
| Field of View (Macro/Micro) | 2.0 × 1.3 – 13.1 × 8.3 mm / 0.2 × 0.13 – 1.31 × 0.83 mm |
| Light Source | Monochromatic Uniform LED, Software-Controllable Intensity |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100OEDM |
| Instrument Type | Benchtop Video Optical Contact Angle & Interfacial Rheometer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Interfacial Tension Range | 0.001–2000 mN/m |
| Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size | ∞ × 290 × 76 mm (L×W×H) |
| Stage Load Capacity | 12 kg |
| Zoom Lens | 6.5× Motorized Zoom Optical System |
| Camera | 1280 × 960 px, 54 fps @ full resolution |
| Field of View | 1.1 × 0.8 to 9.1 × 6.9 mm |
| Vertical Oscillation Unit | ADDU-30XCN (Frequency Range: 0.0005–10 Hz |
| Resolution | 1 ms |
| Max Amplitude | 20 µL |
| Volume/Area Compensation | Active feedback-controlled compensation for evaporation/thermal drift |
| Software | SurfaceMeter v5.x — supports real-time dilatational modulus calculation, multi-frequency sweeps, relaxation analysis, contour-based video logging, and GLP-compliant audit trail |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100POM |
| Instrument Type | Benchtop Laboratory Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Washburn Contact Angle Range | 0–90° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Zoom | 6.5× Motorized Zoom Lens |
| Image Resolution | 1280 × 960 pixels |
| Frame Rate | 54 fps @ full resolution |
| Liquid Level Tracking Precision | 10 µm |
| Absorbed Volume Resolution | 0.1 µL |
| Video Analysis Frequency for Powder Uptake | 15 Hz |
| Standard Capillary Tube | Vertical, 40 mm length × 10 mm diameter |
| Light Source | Adjustable High-Uniformity LED Cold Light |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Base Dimensions & Weight | 600 × 160 × 543 mm (L×W×H), 19 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | LSA100RF |
| Instrument Type | Video-Based Optical Contact Angle & Retention Force Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm (fixed) |
| Max Sample Dimensions | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Zoom | 6.5× Continuous Zoom Lens |
| Centrifuge Control | Programmable Automatic Rotation Stage |
| Max Centrifugal Acceleration | 40 g |
| Rotational Speed Range | 0–750 rpm |
| Speed Control Precision | ±2 rpm |
| Angular Acceleration Range | 1–100 rpm/s |
| Force Resolution | 0.01 µN |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA100SML |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Capillary Meniscus Height Resolution | 10 µm |
| Volume Measurement Resolution | 0.1 µL |
| Imaging Magnification | 6.5× Zoom Optical Lens |
| Maximum Sample Dimensions | ∞ × 290 × 76 mm (L×W×H) |
| Sample Stage Size | 100 × 100 mm |
| Sample Stage Load Capacity | 12 kg |
| Capillary Positioning | Motorized X/Y/Z Precision Translation Stages |
| Image Capture Rate | Up to 150 fps @ 1920×1200 px |
| Lighting | Adjustable High-Uniformity LED Cold Light Source |
| Software | SurfaceMeter Professional Suite with ASTM/ISO-Compliant Data Logging & Audit Trail |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA200 |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Zoom | 8.6× Motorized Telecentric Lens |
| Camera Resolution | 1920 × 1200 px |
| High-Speed Imaging | up to 3300 fps |
| Field of View | 2.1 × 1.3 to 17.5 × 11 mm |
| Software | SurfaceMeter v6.x with ASTM/ISO-compliant algorithms |
| Compliance | ISO 19403-3, ISO 19403-4, DIN 55660-3 |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Dimensions (L×W×H) | 620 × 200 × 536 mm |
| Weight | 22 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA 200 |
| Measurement Range | 0.001–2000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Control Range | −20 °C to 400 °C |
| Temperature Accuracy | ±0.1 °C |
| Measurement Method | Video-based Drop Shape Analysis (DSA) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA200-T |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Dimensions (L × W × H) | ∞ × 310 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Magnification | 6.5× |
| Camera | USB 3.0, 1920 × 1200 px, up to 3300 fps |
| Temperature Control Options | Circulating Fluid or Peltier |
| Tilt Stage | Motorized 360° Continuous Rotation |
| Injection System | Non-contact Electric Dispensing Unit (up to 3 independent syringe modules) |
| Software Compliance | Supports ASTM D724, ISO 19403-2/-3, ISO 15989, USP <1059>, GLP/GMP audit trails (optional) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA200B |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Load | 12 kg |
| Maximum Sample Dimensions (L × W × H) | ∞ × 310 × 76 mm |
| Image Magnification | 6.5× Zoom Lens |
| Automated Tilting Stage | 0–360° |
| Adhesion Force Measurement (Vertical | 0.1 μN resolution |
| Horizontal | up to 40g centrifugal equivalent) |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA200P |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 310 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging Magnification | 6.5× Zoom Lens |
| High-Speed Camera | USB 3.0, 1920 × 1200 px, up to 3300 fps |
| Field of View | 2.7 × 1.7 to 17.5 × 11.0 mm (W×H) |
| Illumination | Monochromatic Uniform LED Cold Light Source |
| Power Supply | 110/240 V, 50/60 Hz, 120 W |
| Dimensions (L×W×H) | 620 × 200 × 543 mm |
| Weight | 19 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA200S |
| Instrument Type | Benchtop Video Optical Contact Angle Meter |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.001–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 290 × 76 mm |
| Stage Load Capacity | 12 kg |
| Imaging System | 1.9× Zoom Lens |
| High-Speed Camera | USB 3.0, 1280 × 1024 px, 60 fps |
| Field of View | 6.5 × 5.2 to 12.4 × 9.9 mm |
| Light Source | Adjustable LED Cold Light |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Instrument Footprint | 620 × 200 × 536 mm (L×W×H) |
| Weight | 22 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA60 pro |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 240 × 76 mm |
| Stage Load Capacity | 12 kg |
| Optical Zoom Lens | 6.5× Continuous Zoom |
| Camera Resolution | 1450 × 1080 pixels |
| Max Frame Rate | 3400 fps |
| Field of View | 1.1 × 0.8 to 14.3 × 10.7 mm |
| LED Illumination | High-Uniformity Cold Light Source, Software- and Manual-Adjustable Brightness |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Dimensions (Base Unit) | 650 × 160 × 517 mm (L×W×H) |
| Weight | 15 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA60 |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 100 mm |
| Maximum Sample Size (L×W×H) | ∞ × 240 × 76 mm |
| Sample Stage Load Capacity | 12 kg |
| Optical Zoom Lens | 6.5× (±6 mm focus adjustment) |
| Imaging System | USB 3.0 high-speed camera, 1280 × 1024 px resolution, up to 435 fps |
| Light Source | Monochromatic, uniform LED cold light with software- and manual-intensity control |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA60G |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Accuracy | ±0.1° |
| Resolution | 0.01° |
| Sample Stage Dimensions | 100 × 100 mm |
| Max. Sample Load | 12 kg |
| Max. Sample Dimensions | ∞ × 240 × 76 mm (L × W × H) |
| Lens | 1.3× Zoom Optical Lens |
| Image Resolution | 752 × 480 pixels |
| Frame Rate | 60 fps @ 752 × 480 |
| Field of View | 8.5 × 5.3 to 10.5 × 6.6 mm |
| Light Source | Monochromatic, Uniform LED Cold Light (Manual & Software-Adjustable Intensity) |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Base Dimensions | 600 × 160 × 517 mm (L × W × H) |
| Weight | 15 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA60P |
| Instrument Type | Benchtop Video Optical Contact Angle Meter |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Resolution | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Max. Sample Weight Capacity | 12 kg |
| Max. Sample Dimensions (L × W × H) | ∞ × 280 × 45 mm |
| Optical Zoom Lens | 1.9× Variable-Focus Lens |
| Camera | USB 3.0, 227 fps @ 1440 × 1080 px |
| Field of View | 1.1 × 0.8 – 9.6 × 7.1 mm |
| Illumination | High-Uniformity LED Cold Light Source (Manually & Software-Adjustable Brightness) |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Instrument Footprint (L × W × H) | 545 × 160 × 432 mm |
| Net Weight | 11 kg |
| Brand | LAUDA Scientific |
|---|---|
| Origin | Germany |
| Model | LSA60T |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | 0.01 mN/m |
| Sample Stage Dimensions | 100 × 100 mm |
| Maximum Sample Load | 12 kg |
| Maximum Sample Dimensions (L × W × H) | ∞ × 240 × 76 mm |
| Tilting Stage Range | 0–100° |
| Tilting Speed | 0.05–7 °/s |
| Optical System | 1.3× Zoom Lens (standard), 752 × 480 px @ 60 fps, FOV: 8.5 × 5.3 to 10.5 × 6.6 mm |
| Illumination | Adjustable High-Uniformity LED Cold Light Source |
| Power Supply | 110/240 V, 50/60 Hz, 90 W |
| Base Dimensions & Weight | 600 × 160 × 517 mm, 15 kg |