| Brand | Leica Biosystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aperio GT 450 |
| Pricing | Available Upon Request |
| Maximum Throughput | 450 slides |
| Slide Rack Capacity | 15 racks × 30 slides or 15 racks × 20 slides |
| Rack Compatibility with Leica HistoCore SPECTRA | Yes |
| Continuous Loading During Scanning | Yes |
| Priority Rack Scanning | Yes |
| Objective Magnification | 40× |
| Pixel Resolution | 0.26 µm/pixel at 40× |
| Scan Speed (15 mm × 15 mm FOV at 40×) | 32 seconds |
| Sustained Throughput | 81 slides/hour |
| Automated Image Quality Control | Yes |
| Slide Dimensions | 1" × 3" (25.4 mm × 76.2 mm) |
| Field of View (FOV) | 1 mm diameter |
| Barcode Recognition | Supports 1D (Code 128, Code 39) and 2D (DataMatrix, QR) symbologies |
| Dimensions (W × L × H) | 20.8" × 23" × 19.5" (52.83 cm × 58.43 cm × 49.53 cm) |
| Weight | 140 lbs (63.5 kg) |
| Brand | Leica Biosystems |
|---|---|
| Origin | Germany |
| Model | CM1520 |
| Maximum Sample Size | 55 mm × 55 mm or 50 mm × 80 mm |
| Section Thickness Range | 2 µm to 60 µm |
| Sectioning Increment | 25 µm + 3 µm step adjustment |
| Brand | Leica Biosystems |
|---|---|
| Origin | Germany |
| Model | CV 5030 |
| Throughput | 400 slides/hour |
| Slide Compatibility | Standard microscope slides and variable coverslip sizes |
| Mounting Media Support | Xylene-based and xylene-free media |
| Operation Modes | Wet-mount and dry-mount |
| Integrated Fume Extraction | Activated carbon filtration system |
| System Integration | Compatible with Leica ST5010/ST5020 stainers |
| Compliance | Designed for GLP/GMP-aligned pathology laboratories |
| Footprint | Open-architecture design for flexible lab integration |
| Brand | Leica Biosystems |
|---|---|
| Origin | Germany |
| Model | HistoCore SPECTRA ST-CV |
| Dimensions (closed) | 135.4 × 78.5 × 58.5 cm |
| Dimensions (open) | 135.4 × 78.5 × 94.3 cm |
| Weight (empty) | 185 kg |
| Weight (loaded) | ~220 kg |
| Power Supply | 100–240 V AC |
| Throughput | up to 330 H&E slides/hour |
| Slide Capacity | 1,600 slides per run |
| Staining Reagent Volume | 380 mL per bottle |
| Slide Rack Capacity | 30 racks (5 dedicated to special stains) |
| Tube Stations | 36 |
| Tube Wash Stations | 6 |
| Input/Output Drawer Slots | 5 per drawer (max. 150 slides continuous load) |
| Integrated Drying Oven | 6-rack capacity |
| Drying Time | ≤5 min |