Leybold
Filter
Showing all 10 results
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | CTR 100 |
| Measurement Principle | Ceramic Diaphragm Capacitance |
| Range | 1000 to 0.1 Torr |
| Vacuum Port | KF 16 |
| Output | 0–10 V analog + RS232 digital interface |
| Accuracy | ±0.12% of full scale |
| Sensor Material | Al₂O₃ ceramic diaphragm with 316 stainless steel flange |
| Temperature Compensation | Integrated |
| Overpressure Tolerance | ≥2× full scale |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | DISPLAY |
| Channel Options | 1-Channel or 3-Channel |
| Pressure Range | 10⁻⁹ mbar to 2000 mbar |
| Compatible Sensor Families | THERMOVAC TTR, DU, PENNINGVAC PTR |
| Compliance | CE, RoHS, EN 61000-6-2/-6-4 |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | GRAPHIX |
| Channel Options | 1-channel, 2-channel, 3-channel |
| Pressure Range | 1×10⁻¹⁰ mbar to 2000 mbar |
| Sensor Compatibility | THERMOVAC TTR, CERAVAC CTR, DU, PENNINGVAC PTR, IONIVAC ITR series active sensors |
| Operating Principle | Digital signal processing of analog or digital outputs from active vacuum sensors |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | IE 514 |
| Measurement Principle | Cold Cathode Ionization |
| Pressure Range | 1 × 10⁻¹² to 1 × 10⁻⁴ mbar |
| Vacuum Flange | CF 40 |
| Compliance | ISO 3567, DIN 28403-1, EN 61000-6-3 |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | PHOENIX Quadro |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5 × 10⁻¹² mbar·L/s |
| Startup Time | ≤ 2 min |
| Response Time | < 1 s |
| Maximum Inlet Pressure | 1500 Pa |
| Helium Purge Speed | 3.1 L/s |
| Leak Rate Display Range | 1 × 10⁻³ to 1 × 10⁻¹³ Pa·m³/s |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | PTR 90 |
| Measurement Principle | Pirani + Cold Cathode (Penning) |
| Range | 1×10³ to 1×10⁻⁸ mbar |
| Vacuum Port | KF 25, CF 40 |
| Output Interface | RS232 / RS485 (digital), optional analog 0–10 V or 4–20 mA |
| Accuracy | ±30% (1×10⁻⁸–1×10⁻² mbar), ±15% (1×10⁻²–10 mbar) |
| LED Indication | Adaptive pulse-mode pressure display |
| Housing | Compact stainless steel, IP65-rated |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TM 201 |
| Measurement Principle | Piezoresistive + Pirani |
| Range | 1200 to 5.0 × 10⁻⁵ mbar |
| Pressure Interface | KF 16 |
| Relative Pressure Capability | –1060 to +1200 mbar |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing environment |
| Brand | Leybold |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | D8C |
| Pump Type | Oil-Sealed Rotary Vane Pump |
| Ultimate Vacuum (with gas ballast closed) | 0.3 mbar |
| Pumping Speed (50 Hz) | 8.11 m³/h |
| Pumping Speed (60 Hz) | 9.65 m³/h |
| Inlet/Outlet Port | DN25 KF |
| Noise Level (LpA) | 54–56 dB(A) |
| Motor Power | 550 W (Single-phase 220 V, 50 Hz or Three-phase 380 V, 50/60 Hz) |
| Oil Type | Leybold LVO 130 |
| Oil Capacity | 1.5 L (max), 1.0 L (min) |
| Net Weight (dry) | 32 kg |
| Dimensions (W × D × H) | 260 × 173 × 272 mm |
| Operating Ambient Temperature | 10–40 °C |
| Maximum Allowable Water Vapor Pressure | 30 mbar |
| Gas Ballast Enabled Ultimate Pressure | ~6 × 10⁻² mbar |
| Gas Ballast Disabled Ultimate Pressure | ~3 × 10⁻² mbar |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TTR 101 |
| Measurement Principle | Combined Pirani + Capacitive Diaphragm |
| Range | 5×10⁻⁵ – 1500 mbar |
| Vacuum Port | KF 16 |
| Compliance | CE, RoHS, ISO 9001-manufactured design |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TTR 91 RN |
| Measurement Principle | Pirani (thermocouple-based thermal conductivity) |
| Range | 1 × 10³ to 5 × 10⁻⁴ mbar |
| Vacuum Port | KF 16 (DN 16) |
| Accuracy | ±50% (100–10 mbar), ±15% (10–1×10⁻³ mbar), ±50% (1×10⁻³–5×10⁻⁴ mbar) |
| Repeatability | ±2% (100–1×10⁻³ mbar) |
| Power Supply | 15–48 V DC |
| Analog Output | 0–10 V |
| Digital Interface | RS232 or RS485 |
| Electrical Connector | RJ45 or 9-pin D-sub |
| Integrated Particle Filter | Yes |
| Filament Options | Tungsten (standard), Platinum (harsh environments) |
| Operating Temperature | 5–60 °C |
| Max Bakeout Temp (electronics removed) | 150 °C |
| IP Rating | IP40 |
| Certifications | CE, UKCA |