LISICO
Filter
Showing all 11 results
| Brand | LISICO |
|---|---|
| Model | Online FTIR Spectrometer |
| Type | Fourier Transform Infrared (FTIR), Online Process Analyser |
| Wavenumber Range | 8000–350 cm⁻¹ (extendable to 12,500–4000 cm⁻¹) |
| Spectral Resolution | < 0.25 cm⁻¹ |
| Wavenumber Accuracy | ≤ 0.01 cm⁻¹ |
| Interferometer | Domestic high-stability立体角镜 interferometer (permanent alignment, >10-year service life) |
| Beam Splitter | Standard KBr-coated mid-IR beam splitter (moisture-resistant option available) |
| Detector | Standard room-temperature DLaTGS |
| IR Source | Long-life ceramic source (1550 K) |
| Probe Material | Hastelloy C-22 |
| Probe Dimensions | Ø12 mm × 300 mm |
| Fiber Type | PIR-900/1000 silver halide fiber |
| Operating Temperature | −100 °C to +140 °C (custom ranges available) |
| Pressure Rating | Up to 200 bar |
| Interface | SMA connector |
| Fiber Length | 1.5 m |
| Minimum Bend Radius | 130 mm |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LS-1 |
| Price Range | USD 14,000 – 70,000 |
| Instrument Type | Low-Field TD-NMR Analyzer |
| Sample Type | Solid–Liquid Suspensions |
| Magnet Type | Samarium–Cobalt Permanent Magnet |
| Static Field Strength | 0.165 ± 0.01 T |
| Larmor Frequency | 7.0 ± 0.3 MHz |
| Frequency Tuning Range | 1–75 MHz |
| Pulse Sequences Supported | FID, Spin Echo (SE), CPMG, Saturation Recovery T₁ (Sat_T1) |
| Relaxation Time Range | 0.1 ms – 10 s |
| Probe Inner Diameter | 20 mm |
| Sample Volume | 1–5 mL |
| Measurement Repeatability | ±2% |
| Frequency Resolution | 0.28 Hz |
| Phase Accuracy | 0.09° |
| Timing Resolution | 13.3 ns |
| Sampling Rate | 75 MS/s |
| Maximum Acquisition Bandwidth | 10 MHz |
| Minimum Echo Spacing | 150 µs |
| Maximum Echo Train Length | 60,000 |
| Brand | LISICO |
|---|---|
| Model | LS-100 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Configuration | Modular Benchtop System |
| Optical Architecture | Michelson Interferometer with Solid-State Laser Reference |
| Spectral Range | 10,000–4,000 cm⁻¹ (1,000–2,500 nm) |
| Resolution | Adjustable down to 4 cm⁻¹ |
| Detector | Thermoelectrically Cooled InGaAs |
| Sampling Modes | Transmission (liquids), Diffuse Reflectance (solids), Non-contact Reflectance (Dual-Eye probe) |
| Connectivity | USB 3.0, Ethernet, Optional Fiber-Optic Interface (up to 8 channels) |
| Software Platform | S-Cal (PLS/QPLS modeling), S-Seq (automated sequence control), S-Online (real-time DCS integration) |
| Brand | LISICO |
|---|---|
| Model | LS-100-Pro |
| Type | Online FT-NIR Spectrometer |
| Channels | 8-channel multiplexed |
| Form Factor | Integrated cabinet system with embedded industrial PC, temperature control module, and PLC for DCS integration |
| Dimensions | 540 mm × 350 mm × 650 mm (L×W×H) |
| Weight | 10 kg (excluding spectrometer optics core) |
| Origin | Shanghai, China |
| Instrument Category | Domestic manufactured |
| Distribution Model | Authorized distributor supply |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Model | LS-O (Rotating Bomb Oxidation Method) |
| Detection Parameter | Oxidation Stability |
| Temperature Control Points | 140.0 ± 0.1 °C and 150.0 ± 0.1 °C |
| Rotation Speed | 100 ± 5 rpm |
| Pressure Range | 0–1.6 MPa (Pressure Sensor Accuracy: ±0.1% FS |
| Precision Gauge | 0.25 Class) |
| Power Consumption | ≤1400 W |
| Dimensions | 300 × 500 × 500 mm (W × D × H) |
| Weight | 40 kg |
| Compliance Standards | SH/T 0193, ASTM D2272 |
| Interface | Ethernet for LIMS integration |
| Data Storage | Local HDD with persistent multi-test archive |
| Max Concurrent Units per PC | 4 |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LS-U |
| Detection Principle | Ultraviolet Fluorescence (UVF) |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur |
| Measurement Range | 0.1 mg/L to >10,000 mg/L (0.2 ppm to >1% w/w) |
| Accuracy | ±0.1 mg/L (for 0.1 ≤ X < 1.0 mg/L) |
| Sample Volume | 5–50 µL (liquid) |
| Carrier Gas | Ultra-high-purity Argon (99.999%) and Oxygen (99.999%) |
| Furnace Temperature Range | Ambient to 1150 °C ±2 °C |
| Operating Environment | 5–30 °C, stable ambient conditions |
| Power Supply | 220 V ±10%, 50 Hz, 3 kW (15 A) |
| Software Interface | Switchable Chinese/English GUI |
| Compliance Standards | SH/T 0689, ASTM D5453, ASTM D4629, ASTM D5762 |
| Data Management | LIMS-ready architecture with audit trail capability |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | LS-V |
| Pricing | Upon Request |
| Brand | LISICO |
|---|---|
| Model | LS1000 |
| Measurement Principle | Near-Infrared Absorption (1.43 µm, 1.8 µm, 1.94 µm, 2.1 µm) |
| Moisture Range | 0–70% H₂O |
| Accuracy | ±0.1% H₂O (application-dependent) |
| Repeatability | ±0.04% H₂O |
| Sampling Interval | 10 ms |
| Optical Path | 8-beam wavelength multiplexing |
| Light Source | 12 V / 20 W halogen lamp (≥2000 h lifetime) |
| Detector | Thermoelectrically cooled PbS infrared detector |
| Measurement Distance | 250 ± 100 mm |
| Spot Diameter | 60 mm |
| Probe Housing Material | Anodized aluminum alloy |
| Probe IP Rating | IP67 |
| Probe Dimensions | 194 × 194 × 320 mm |
| Probe Weight | ≤12 kg |
| Controller Display | 10-inch capacitive touchscreen |
| Controller OS | Android 8.0 |
| Internal Storage | 32 GB |
| Max. Probe Support per Controller | 4 |
| Communication Interfaces | 4–20 mA analog output, USB ×2, DC power input (24 V / 3 A) |
| Cooling Method | Forced-air convection |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 40–60% RH (non-condensing) |
| Cable Length | Probe-to-controller ≥10 m (shielded twisted pair), controller cables ≥20 m |
| Brand | LISICO |
|---|---|
| Model | Online 1 |
| Measurement Principle | Mie & Fraunhofer Light Scattering |
| Test Range | 0.1–1000 µm |
| Repeatability Error | ≤1% (D50 of certified reference material) |
| Accuracy Error | ≤1% (D50 of certified reference material) |
| Sampling Method | Venturi-based negative-pressure sampling with anti-clogging design |
| Lens Protection | Dual-air-curtain optical protection |
| Maintenance Interval | ≥180 days |
| Laser Source | Imported semiconductor laser |
| Detector Array | 68-element photodiode array |
| Operating System | Windows |
| Communication Protocols | Modbus RTU, TCP/IP, 4–20 mA analog output |
| Dispersing Medium | Compressed air or inert gas (N₂) |
| Gas Supply | 0.4–0.8 MPa, ≥1000 L/min |
| Filtration System | 4-stage imported precision filter (particulate, oil, moisture removal) |
| Sample Throughput | 2–20 g per cycle |
| Power Supply | AC 220 V, 50/60 Hz, 90 W |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 800 × 280 × 280 mm |
| Weight | 21 kg |
| Compliance | GB/T 19077–2016, ISO 13320:2009, Q/ASA 001–2021 |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Online 2 |
| Pricing | Upon Request |
| Brand | LISICO |
|---|---|
| Model Series | SRV / SRD / DVP / DVM |
| Measurement Principle | Torsional Resonance (Viscosity & Density) |
| Viscosity Range | 0–3,000 mPa·s (cP), up to 50,000 mPa·s (cP) optional |
| Density Range | 0–1.5 g/mL, extended range available |
| Viscosity Accuracy | ±1% of reading or better (customizable) |
| Density Accuracy | ±0.01 g/mL standard, ±0.001 g/mL optional |
| Viscosity Resolution | 0.001 mPa·s (cP) |
| Density Resolution | 0.001 g/mL |
| Temperature Sensor | Pt1000 (Class B or AA), integrated |
| Operating Temp | −50 to +300 °C (model-dependent) |
| Pressure Rating | up to 207 MPa (30,000 psi) |
| Wetted Materials | 316L SS or Titanium Grade 5 |
| Enclosure Rating | IP68/IP69, Ex ia IIC T2–T6 |
| Response Time | <1 s |
| Sample Volume | 0.7 mL |
| Electrical Interface | M12 connector or fixed cable |
| Process Connection | 3/4″ NPT, sanitary clamp, 1″ NPT, or 1/4″ HP (9/16-18 UNF) |