MAIERIC
Filter
Showing all 14 results
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | DEMT-8/16 |
| Detector Type | Custom Electromagnetic Sensor Array |
| Spatial Resolution | 5% of cross-sectional diameter |
| Density Resolution | Configurable (system-dependent) |
| Penetration Capability | Customizable per application |
| Measurement Range | Configurable (up to Ø300 mm cross-section) |
| Dimensional Accuracy | ±5% of cross-sectional dimension |
| Density Measurement Accuracy | Configurable |
| Operating Temperature | Up to 300 °C (non-contact probe interface) |
| Imaging Modes | Dual-mode (Eddy Current Tomography & Metal Flaw Detection) |
| Signal-to-Noise Ratio (SNR) | 60–90 dB |
| Frequency Range | 1 kHz–200 kHz (standard) |
| Channel Configuration | 8 or 16 independently configurable channels |
| Sampling Rate | Up to 100 kS/s per channel (flaw detection mode) |
| Reconstruction Grid | Up to 32×32 pixels (1% cross-sectional area resolution) |
| Front-End Signal Processing | Programmable 3-stage gain amplifier (1×–8×), with optional expansion |
| Data Output | Complex impedance components (real, imaginary, magnitude, phase), full complex-plane representation |
| Core Platform | FPGA-based digital acquisition and real-time processing architecture |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Array Eddy Current Testing Instrument |
| Inspection Method | Automated Scanning |
| Eddy Current Signal Type | Multi-Frequency Eddy Current |
| Design Form Factor | Portable |
| Number of Channels | Customizable |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MAIERIC |
| Measurement Principle | Combined DC-biased hysteresis loop tracing + high-frequency Barkhausen noise detection |
| Signal Acquisition | Dual-channel synchronized B–H and MBN waveform capture |
| Excitation Frequency Range | 0.1–100 Hz (programmable) |
| MBN Bandwidth | 20 kHz–1 MHz (programmable bandpass filter) |
| Data Output Format | .db (binary database with timestamped MBN, B, H waveforms) |
| Interface | Wi-Fi-enabled real-time PC control |
| Compliance | Designed for ASTM E1444/E2884-compliant magnetic testing workflows |
| Software Features | Real-time x–y scalable plotting of B(H), H(t), and MBN(t) |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | BH Hysteresis Loop & Barkhausen Noise Analyzer |
| Measurement Principle | Dual-mode electromagnetic induction + Hall-effect field sensing + high-frequency MBN detection |
| Excitation Frequency Range | 1 Hz – 1 kHz (programmable) |
| Signal Acquisition | Simultaneous B (flux density), H (magnetic field strength), and MBN (Barkhausen noise) waveforms |
| Data Output Format | .db (binary database with timestamped raw channels) |
| Real-time Display | Adjustable XY scaling for B–H loop, H(t), MBN envelope, and time-domain MBN burst trains |
| Connectivity | Wi-Fi 802.11n (IEEE 802.11 compliant), USB 2.0 backup |
| Filtering | Programmable bandpass filter (10 kHz – 1 MHz, 3rd-order IIR) for MBN |
| Amplification | Programmable preamplifier gain (20 dB – 60 dB, 10 dB steps) |
| Compliance | Designed per IEC 60404-4 (magnetic materials — methods of measurement of DC magnetic properties) and ASTM A341/A341M (standard test method for direct-current magnetic properties of materials) |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | BH-MBN-1000 |
| Measurement Principle | Dual-mode electromagnetic induction + Hall-effect field sensing + high-sensitivity MBN coil detection |
| Excitation Frequency Range | 1 Hz – 10 kHz (programmable) |
| MBN Bandpass Filter | 20 kHz – 2 MHz (adjustable center frequency & bandwidth) |
| Signal Acquisition | Simultaneous real-time sampling of B (flux density), H (magnetic field strength), and MBN voltage waveform |
| Data Output Format | SQLite (.db) with timestamped raw channels, calculated coercivity (Hc), remanence (Br), and MBN RMS/peak amplitude |
| Interface | Wi-Fi 802.11n (IEEE 802.11 compliant), USB 2.0 fallback |
| Software Platform | Windows 10/11 native application with GLP-compliant audit trail logging (user action timestamps, parameter change history, export metadata) |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | CFT-1 |
| Coercivity Range | 1–50 A/cm |
| Measurement Depth | Up to 30 mm |
| Surface Clearance | Up to 6 mm |
| Measurement Speed | ~3.5 s per reading |
| Excitation Levels | 3 adjustable intensity settings |
| Data Storage | 32 GB internal (DB & CSV export) |
| Display | 2K full-touchscreen interface |
| Compliance | Designed for field-deployable non-destructive evaluation (NDE) of ferromagnetic components |
| Interface | USB, HDMI, sensor port |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CFT-Series |
| Pricing | Upon Request |
| Excitation Levels | 3 Adjustable Steps |
| Lift-off Tolerance | Up to 6 mm |
| Measurement Speed | 3.5 s per reading |
| Penetration Depth | 30 mm |
| Coercivity Range | 1–50 A/cm |
| Display | 2K Full-Touch LCD |
| Storage Capacity | 32 GB (DB + CSV export) |
| Measurement Modes | Manual Keypad / Continuous Auto-Scan |
| Calibration | Intelligent Auto-Calibration Routine |
| Imaging | Built-in 1D/2D Mapping Visualization |
| Data Export | Standard DB & CSV formats |
| Compliance | Designed for ASTM E1444/E709-compliant magnetic particle inspection workflows and ISO 10893-1 non-destructive testing requirements |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MBN-2000 |
| Measurement Principle | Electromagnetic Induction + Hall Effect + High-Frequency Eddy Current Coupling |
| Signal Bandwidth | 10 kHz – 2 MHz (programmable bandpass) |
| MBN Preamp Gain | 20–80 dB (software-adjustable) |
| Excitation Frequency Range | 1 Hz – 1 kHz |
| Excitation Voltage Amplitude | 0–20 Vpp (programmable) |
| Data Storage Format | SQLite (.db) with timestamped raw MBN, B, and H waveforms |
| Real-time Display | Dual-axis XY plot (H vs. B, MBN envelope vs. H) with scalable axes |
| Connectivity | IEEE 802.11n Wi-Fi (2.4 GHz), USB 2.0 fallback |
| Compliance | Designed per IEC 60404-6 (magnetic measurement methods), compatible with ASTM A932/A932M (standard test method for Barkhausen noise evaluation of ferromagnetic materials) |
| Brand | MAIERIC |
|---|---|
| Model | MBN-BH Grinding Burn Detector |
| Measurement Principle | Magnetostrictive Barkhausen Noise (MBN) + Quasi-Static B-H Hysteresis Loop Analysis |
| Core Components | U-Core Excitation/Detection Probe with Integrated Hall Sensor & Miniature MBN Pickup Coil |
| Signal Acquisition | Simultaneous Real-Time MBN, B(t), and H(t) Waveforms |
| Data Output | .db Binary Format with Timestamped Raw Signals |
| Connectivity | Wi-Fi Enabled PC-Based Control Interface |
| Software Features | Programmable Excitation Frequency/Amplitude, Adjustable MBN Bandpass Filter, Configurable Pre-Amplifier Gain, Dual-Axis Scalable XY Plotting (B vs. H, MBN vs. Time, H vs. Time) |
| Compliance Context | Designed for GLP-aligned magnetic property evaluation per ASTM A342/A342M (Permeability), ISO 643 (Metallographic Hardness Correlation), and internal QC protocols for aerospace & automotive component manufacturing |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MTIA |
| Instrument Type | Mid-Frequency Impedance Analyzer |
| Frequency Range | 0.05 Hz – 10 MHz |
| Frequency Resolution | 0.05% of set frequency |
| Basic Measurement Accuracy | ±0.05% |
| Impedance Range | 20 mΩ – 1 GΩ |
| Measurement Speed | 10,000 samples/s |
| Measurement Modes | Four-Terminal (Kelvin), Multi-Channel (up to 128 channels) |
| Excitation Voltage Range | 0.02 V – 2.0 V (10 mV resolution) |
| Compensation Methods | Open-Short-Load, Open-Load, Short-Load, Load-only |
| Supported Parameters | Z, θ, R, X, Ls/Lp, Cs/Cp, D, Q, Y, G, B |
| Equivalent Circuit Modeling | Yes |
| Data Visualization | Sweep plots, multi-channel mapping, time-series traces |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MTIA-8 |
| Instrument Type | Medium-Frequency Impedance Analyzer |
| Frequency Range | 0.01 Hz – 10 MHz |
| Frequency Resolution | 0.05 Hz |
| Basic Measurement Accuracy | ±0.05% |
| Impedance Range | 20 mΩ – 1 GΩ |
| Measurement Speed | 10,000 samples per second |
| Channel Capacity | Up to 128 parallel measurement channels (hardware-expandable) |
| Measurement Modes | Four-Terminal (Kelvin), Multi-Channel Synchronized Acquisition |
| Excitation Voltage Range | 0.02 V – 2.0 V (10 mV resolution) |
| Compensation Methods | Open-Short-Load, Open-Load, Short-Load, Load-only |
| Supported Parameters | Z, θ, R, X, Ls/Lp, Cs/Cp, D, Q, Y, G, B, Rs, Rp |
| Equivalent Circuit Fitting | Up to 7-element models (e.g., R-C, R-L-C, R-(C//R), etc.) |
| Brand | MAIERIC |
|---|---|
| Model | MTIA-A |
| Measurement Frequency Range | 0.05 Hz – 10 MHz |
| Basic Accuracy | ±0.05% |
| Impedance Range | 20 mΩ – 1 GΩ |
| Measurement Speed | Up to 10,000 samples/sec |
| Resolution | 0.05 Hz (frequency), 0.01 V (voltage) |
| Excitation Voltage Range | 0.02 V – 2 V |
| Measurement Modes | Four-Terminal (Kelvin), Multi-Channel (up to 128 channels, 16 active simultaneously) |
| Impedance Parameters | Z, R, X, L, C, D, Q, θ |
| Compensation Methods | Open-Short-Load, Open-Load, Short-Load, Load-only |
| Analysis Features | Equivalent Circuit Modeling, Time-Domain Sequence Plotting, Multi-Channel Compensation, Sweep & Multi-Channel Mapping |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | PECT-1 PULSED EDDY CURRENT |
| Design | Portable |
| Inspection Method | Pulsed Eddy Current (PEC) |
| Signal Type | Transient Electromagnetic Response |
| Measurement Integration | Encoder-based Position Tracking |
| Lift-off Tolerance | Up to 160 mm |
| Wall Thickness Range | 1–30 mm |
| Non-ferromagnetic Cladding Penetration | Up to 2 mm |
| Cladding Thickness Variation Compensation | ±50% with ≤±2% measurement deviation |
| Imaging Mode | User-configurable 2D grid mapping with real-time coordinate registration |
| Compliance | Designed for ASTM E2884-23 (Standard Guide for Pulsed Eddy Current Examination), ISO 12718:2019 (Non-destructive testing — Vocabulary — Eddy current testing), and GLP-aligned data integrity workflows |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | TEST |
| Measurement Principle | Electromagnetic Induction + Hall Effect + High-Frequency Eddy Current Coupling |
| Core Functions | Simultaneous MBN Signal Acquisition, Quasi-Static BH Loop Tracing, Coercivity & Remanence Calculation |
| Connectivity | Wi-Fi (IEEE 802.11 b/g/n), USB 2.0 |
| Signal Bandwidth | MBN Channel: 50 kHz – 1.2 MHz (programmable bandpass filter), B/H Channels: DC – 10 kHz |
| Data Output Format | SQLite .db (timestamped raw MBN, B, H waveforms + calculated hysteresis parameters) |
| Software Interface | Windows-based GUI with real-time XY scaling, parameter sweep capability, and export to CSV/MAT |