MappingLab
Filter
Showing all 4 results
| Brand | MappingLab |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Single-Well Format |
| Application Domain | In Vitro Electrophysiology |
| Electrode Configurations | 32-, 64-, 128-, and 256-channel flexible or rigid substrates |
| Substrate Options | Polyimide-based flexible arrays (thickness down to 10 µm) and glass-based rigid arrays (50 × 50 × 1 mm base |
| electrode diameters | 20/30/50 µm |
| well inner diameter | 22 mm) |
| Compatibility | Langendorff-perfused hearts, open-chest in vivo preparations, tissue slices, monolayer cardiomyocyte cultures |
| Mechanical Integration | Compatible with MappingLab multi-axis micromanipulator (universal joint mount), perfusion chambers, Faraday cages, and humidified incubator environments |
| Regulatory Context | Designed for GLP-compliant preclinical cardiac electrophysiology studies |
| Brand | MappingLab |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MVC-801 |
| Instrument Type | Semi-Automatic |
| Control Interface | Analog (0–5 V / 0–10 V) & Digital (TTL/BNC) |
| Valve Count | 8 Independent Solenoid Valves |
| Valve Specifications | 12 V DC, Max 4 W per valve, Min 24 Ω resistance |
| Cascade Capability | 11 Isolated BNC Trigger Inputs/Outputs |
| Memory Function | Yes (Last Valid Configuration Retained) |
| Overflow Protection | Integrated Flow Monitoring with Audible/Visual Alert |
| Software Compatibility | Native Integration with pCLAMP (Axon), PatchMaster (HEKA), and Custom LabVIEW/Python Scripts |
| Regulatory Context | Designed for GLP-compliant electrophysiology laboratories |
| Brand | MappingLab |
|---|---|
| Origin | Beijing, China |
| Model | SG-WH012 |
| Instrument Type | Manual |
| Temperature Control Range | Ambient to 100 °C |
| Flow Rate Range | 0.02–380 mL/min |
| Pump Speed Range | 0.1–100 rpm (bidirectional adjustable) |
| Temperature Accuracy | ±0.5 °C |
| Water Bath Dimensions | 390 × 330 × 180 mm |
| Perfusion Chamber Volume | 200 mL / 500 mL |
| Return Reservoir Volume | 100 mL / 200 mL |
| Speed Resolution | 0.1 rpm |
| Peristaltic Pump Dimensions | 232 × 142 × 149 mm |
| Operating Environment | 0–40 °C, RH < 80% |
| Ingress Protection Rating | IP31 |
| Brand | MappingLab |
|---|---|
| Model | VCS-3002 |
| Output Modes | Constant Voltage & Constant Current |
| Voltage Range | ±90 V |
| Current Range | ±32 mA |
| Voltage Accuracy | ±0.1 V |
| Current Accuracy | ±20 µA |
| Max Output Frequency | 30 kHz |
| Pulse Duration Stability | Up to 200 h continuous operation |
| Isolation | Built-in galvanic isolation (no external isolator required) |
| I/O Interface | TTL-triggered stimulation, analog/digital I/O connectors |
| Protection | Integrated overcurrent and overvoltage protection |
