Megger
Filter
Showing all 9 results
| Brand | Megger |
|---|---|
| Origin | USA |
| Model | FREJA 546 |
| Output | 3× AC Current Channels (60 A rms, 300 V rms per phase) |
| Accuracy | ±0.05% rdg + 0.02% range (voltage/current) |
| Operating Temperature | 0°C to 50°C |
| Weight | 13.2 kg |
| Dimensions | 337 × 172 × 273 mm |
| Brand | Megger |
|---|---|
| Model | MIT525 |
| Test Voltage Range | 250 V to 5 kV (5 preset + user-defined) |
| Max Resistance Measurement | 10 TΩ |
| Short-Circuit Current | 3 mA |
| Accuracy | ±5% up to 1 TΩ, ±20% up to 10 TΩ |
| Display | Backlit LCD with dual-parameter readout |
| Battery | 11.1 V Li-ion, 5.2 Ah, ~6 h continuous operation at 5 kV |
| Charging | AC mains operation during test |
| Safety Rating | CAT IV 600 V, double insulation, IP65 (lid closed) |
| Compliance | IEC 61010-1, IEC 61326-1, IEC 61010-31:2008 (test leads) |
| Dimensions | 315 × 285 × 181 mm |
| Weight | 4.5 kg |
| Data Interface | Isolated USB-B (device mode), compatible with Megger PowerDB Lite |
| Diagnostic Modes | PI, DAR, DD, SV, Ramp Test |
| Voltage Meter Function | 30–660 V ac/dc, ±3% ±3 V |
| Noise Rejection | Up to 3 mA interference suppression |
| Altitude Operation | Rated CAT IV 600 V up to 3000 m |
| Key | Brand: Megger |
|---|---|
| Model | MIT525 |
| Test Voltage Range | 50 V to 5 kV (adjustable in 10 V steps up to 1 kV, 25 V steps above) |
| Maximum Insulation Resistance Measurement | 10 TΩ |
| Short-Circuit Current | 3 mA |
| Display | Backlit LCD with multi-parameter real-time readout (resistance, voltage, leakage current, capacitance, time constant, battery status, elapsed test time) |
| Battery | Rechargeable Li-ion, 6 h continuous operation, 2.5 h full charge |
| Ingress Protection | IP65 |
| Safety Rating | CAT IV 600 V (up to 3000 m altitude) |
| Compliance | IEC 61010-1, IEC 61557-2 |
| Software Compatibility | PowerDB™ analysis software (via USB/RS232) |
| Real-Time Clock & Temperature Logging | Yes |
| Diagnostic Test Modes | IR, IR(t), PI, DAR, DD, SV (Step Voltage), Ramp Test |
| Input Protection | 3 mA noise immunity, ±2% accuracy at 100 MΩ load (500 kΩ leakage protected) |
| Dual-Shell Housing | Outer impact-resistant shell + inner flame-retardant shell |
| Brand | Megger |
|---|---|
| Model | MIT525 |
| Test Voltage Range | 50 V to 5 kV (5 preset + user-defined) |
| Maximum Resistance Measurement | 10 TΩ |
| Accuracy | ±5% up to 1 TΩ at 5 kV |
| Short-Circuit Current | 3 mA |
| Safety Rating | CAT IV 600 V, Double Insulation |
| Ingress Protection | IP65 (enclosure) |
| Operating Altitude | Up to 3000 m |
| Battery | Rechargeable Li-ion, 6 h continuous operation at 5 kV |
| Charging Time | 1.5 h (full charge) |
| Display | Backlit LCD with multi-parameter readout |
| Data Storage | Internal memory with time/date stamping |
| Interface | Isolated USB-B port for PowerDB software integration |
| Compliance | IEC 61010-1, IEC 61010-2-033, IEC 61010-31:2008, IEEE 43, ASTM D257, BS EN 60204-1 |
| Brand | Megger |
|---|---|
| Origin | USA |
| Model | MOM600A |
| Voltage Options | 115 V AC / 230 V AC |
| Output Current Range | 0–600 A DC |
| Resistance Measurement Range | 0–1999 µΩ |
| Resolution | 1 µΩ |
| Accuracy | ±1% of reading + 1 digit (at 100–600 A) |
| Operating Temperature (115 V) | 0°C to +50°C |
| Operating Temperature (230 V) | 0°C to +40°C |
| Storage Temperature | −40°C to +70°C |
| Humidity | 5–95% RH, non-condensing |
| Dimensions (Instrument) | 356 × 203 × 241 mm |
| Weight (115 V unit) | 25 kg |
| Weight (230 V unit) | 24.7 kg |
| Brand | Megger |
|---|---|
| Origin | United Kingdom |
| Model | SMRT43D |
| Output Channels | 4 Voltage, 3 Current (expandable to 6 current via VIGEN channel conversion) |
| Max Current Output | 135 A (single-phase, 900 VA peak) |
| Max Voltage Output | 300 V AC (per channel, 150 VA) |
| Touchscreen Display | 7-inch full-color high-resolution TFT LED |
| Compliance | EN 61010-1, EN 61326-2-1, EN 61000-4-x, IEC 61850 GOOSE/SV support |
| Operating Temperature | 0–50 °C |
| Weight | 13.2 kg (with 3 VIGEN modules) |
| Dimensions | 337 × 172 × 273 mm (W×H×D) |
| Brand | Megger |
|---|---|
| Origin | USA |
| Model | SVERKER 900 |
| Output Voltage | 900 V AC (per phase), 900 V DC |
| Output Current | 105 A AC (per channel), 10 A DC |
| Frequency Range | 10 Hz – 600 Hz + DC |
| Channels | 3 independent current sources, 4 independent voltage sources |
| Phase Angle Adjustment | 0°–360°, resolution ≤ 0.1° |
| Isolation | Fully galvanically isolated between all outputs and earth |
| Operating Temperature | 0°C to +50°C |
| IP Rating | IP2X (enclosure), compliant with IEC 61010-1:2010 |
| Safety Compliance | CE marked per IEC 61326-1 (EMC) and IEC 61010-1 (LVD) |
| Dimensions (unit) | 350 × 270 × 220 mm |
| Weight | 14.9 kg |
| Brand | Megger |
|---|---|
| Origin | United Kingdom |
| Model | TORKEL900/TORKEL910 |
| Maximum Discharge Current | 220 A |
| Operating Modes | Constant Current, Constant Power, Constant Resistance, Programmable Load Profile |
| Integrated Data Logging | Voltage, Capacity, Time |
| Safety Features | Spark-Free Connection, Emergency Fuse, Auto-Discharge Termination, Hardware Emergency Stop |
| Interface | 7" Touchscreen Display, USB Storage Port, Ethernet (Service Only), Isolated TXL Stop Output, Relay Alarm Output, DC 9 V Auxiliary Supply, I_EXT ≤ 1 V External Current Input |
| Compliance | Designed for IEC 61000-4 Immunity, EN 61010-1 Safety, and Compatible with IEEE 450 / IEEE 1188 Maintenance Standards |
| Software Export | CSV via USB flash drive |
| Brand | Megger |
|---|---|
| Origin | United Kingdom |
| Model | VLF CR-60HP |
| Output Voltage | 0–60 kV RMS (VLF), 0–±60 kV DC |
| Frequency | 0.1 Hz |
| Max Capacitive Load | 6.5 µF @ 0.1 Hz / 60 kV RMS |
| Output Current | 0–17 mA (10 µA resolution) |
| Leakage Current Measurement | Integrated |
| Breakdown Detection | Real-time |
| Sheath Fault Location | 0–10 kV, Duty Cycle 1:3 / 1:5 / 1:9 |
| Input | 115 V / 230 V ±10%, 50/60 Hz, 1900 VA |
| Dimensions (W×H×D) | 1350 × 1250 × 1100 mm (1500 mm with rear access panel) |
| Weight | 380 kg |
| IP Rating | IP20 |
| Operating Temperature | –25 °C to +55 °C |
| Storage Temperature | –40 °C to +70 °C |