Metrohm
Filter
Showing 91–102 of 102 results
| Brand | Metrohm |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PRO Online NIR |
| Instrument Type | Online Process Analyzer |
| Application Field | Petrochemical Industry |
| Operating Principle | Fixed Grating with Diode Array Detector (Non-Scanning) |
| Wavelength Range | 1100–1650 nm (Reflectance), 850–1050 nm (Transmittance) |
| Scan Speed | 0.5 s per spectrum |
| Spectral Sampling Interval | 0.5 nm |
| Sample Interface Modes | Diffuse Reflectance (Solids), Transflectance (Liquids), Transmission (Liquids) |
| Chemometrics Software | Vision with ISIcal™ |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SECM |
| Instrument Type | Multichannel Electrochemical Workstation |
| Current Range | 10 pA – 100 pA |
| Current Resolution | 0.3 fA |
| Potential Accuracy | ±0.3 µV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Positioning System | XYZ Stepper Motor Control |
| Scan Volume (Standard) | 25 × 25 × 25 mm |
| Max Linear Scan Speed | 10 mm/s |
| Spatial Resolution | 20 nm |
| Operating Modes | Feedback Mode, Generation-Collection (GC) Mode, Direct Mode, AC-SECM (Local Impedance), 4D Mode, Shear-Force Mode |
| Scan Types | 2D, 3D, Equidistant, Fast Equidistant, User-Defined Electrochemical Protocol Scans |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Laboratory Instrument Maintenance & Support Service |
| Model | MSA |
| Service Fee Range | USD 1,200–2,400/year (approx.) |
| Field Experience | >10 years |
| Response Time | 4–8 hours |
| Scope of Service | Preventive maintenance, performance verification, corrective repair, operator training, application support, calibration verification, and spare parts logistics |
| Coverage | Nationwide (China) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SPELEC RAMAN |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±40 mA |
| Current Accuracy | ≤0.5% of full scale |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±4 V |
| AC Impedance Frequency Range | Not specified |
| Optical Detection Range | 350–1050 nm (UV/VIS spectrometer integrated) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Import Status | Imported |
| Model | SPELEC |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Single-Channel |
| Current Range | ±40 mA |
| Current Accuracy | ≤0.5% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±4 V |
| EIS Frequency Range | 10 mHz – 1 MHz |
| Optical Detection Ranges | 200–900 nm or 350–1050 nm (user-selectable) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPELECNIR |
| Instrument Type | Multichannel Electrochemical Workstation |
| Current Range | ±1 nA to ±10 mA |
| Current Accuracy | ±0.5 % of reading |
| Potential Accuracy | ±0.2 % of full scale |
| Potentiostatic Range | ±4 V |
| Impedance Frequency Range | Not applicable (dedicated EC–NIR coupling system, not EIS-capable) |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-1064 |
| Spectral Range | 176–2900 cm⁻¹ |
| Spectral Resolution | 9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 176 cm⁻¹ |
| Spectral Repeatability | ±1 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-N |
| Spectral Range | 176 – 2900 cm⁻¹ |
| Spectral Resolution | ~9 cm⁻¹ at 912 nm |
| Compliance | Designed for forensic field use in accordance with ISO/IEC 17025–aligned operational protocols |
| Software | Embedded spectral library with remote update capability |
| Detection Technology | Conventional Raman + optional SERS (via TacPac™ accessory) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Models | TitrIC System 1, TitrIC System 2, TitrIC System 3 |
| Pricing | Available upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab |
| Type | Electrochemical Workstation |
| Model | VIONIC |
| Current Range | ±6 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±6 A |
| EIS Frequency Range | 10 µHz – 10 MHz |
| Compliance Voltage | ±50 V |
| Minimum Sampling Interval | 1 µs |
| Floating Mode | Optional |
| Dual Reference Electrode Support (S2) | Yes |
| Electrochemical Cell Isolation | Yes |
| Oscillation Protection | Yes |
| Independent Cell Switch | Yes |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Spectral Range | 176–2500 cm⁻¹ |
| Excitation Wavelength | 1064 nm |
| Compliance | FDA 21 CFR Part 11, USP <858>, Ph. Eur. 2.2.48, JP 2.26, ChP 2020 Raman Spectroscopy General Chapter |
| Application Focus | GMP-compliant raw material identity testing (RMIT), incoming material verification, counterfeit detection |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm |
| Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 176–2500 cm⁻¹ |
| Spectral Resolution | 10 cm⁻¹ |
| Minimum Wavenumber | 176 cm⁻¹ |
| Spectral Reproducibility | <1 cm⁻¹ |
| Laser Wavelength | 1064 nm |