Microtrac
Filter
Showing all 17 results
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MAX X |
| Instrument Type | Static Vapor Adsorption Analyzer |
| Pressure Sensor Ranges | 1000 Torr / 10 Torr / 0.1 Torr |
| Temperature Control | Heated Manifold (50 °C standard, optional 80 °C), Air-Bath Sample Chamber |
| Gas Path | Electropolished Stainless Steel with Metal-Sealed Pneumatic Valves |
| Free Space Compensation | Patented Advanced Free Space Measurement (AFSM™) Technology |
| Vapor Compatibility | H₂O, Ethanol, Benzene, and other non-corrosive VOCs (up to 40 °C standard |
| Gas Inlets | Standard 3-port corrosion-resistant |
| Measurement Modes | High-Precision Mode (3 sample + 1 reference station) & Multi-Station Mode (4 sample stations + dedicated P₀ port) |
| Software | BELCONTROL OS with real-time trend logging, system diagnostics, email status alerts, and multilingual UI (English/Japanese) |
| Compliance Support | Designed for GLP/GMP-aligned workflows |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MR1 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Dynamic Gas Flow Adsorption Method |
| Analysis Stations | 1 Pre-treatment Station, 1 Analysis Station |
| Surface Area Range | >0.01 m²/g |
| Pressure Range | 0.30 (standard), 0.02–0.9 (upgraded) |
| Adsorptive Gases | He/N₂ or He/Kr mixtures |
| Pretreatment Temperature | Room Temperature to 400 °C |
| Repeatability | <±1% |
| Measurement Time per Sample | ~10 min (analysis only) |
| Compliance Option | FDA 21 CFR Part 11 & 3Q Validation Support |
| Control Interface | Integrated Touchscreen (standalone operation) |
| Dimensions | W350 × D368 × H553 mm |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | AEROTRAC II |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.5–2,000 µm |
| Repeatability | ≤1% |
| Measurement Time | 10–15 seconds |
| Optical Principle | Static Laser Diffraction with Full-Range Mie Theory Processing |
| Laser Source | Semiconductor Laser |
| Auto-Focusing | Yes |
| Trigger Mode | Automatic Pulse Detection |
| Software Platform | Windows-Compatible Analysis Suite |
| Optional Accessories | PD-10S Dry Spray Module, SC-13 Wet Dispersion Unit, MB-600 Motorized Translation Stage |
| Compliance | Designed for ASTM E799, ISO 13320, and USP <429> alignment |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELCAT II |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Dynamic Flow Method |
| Number of Gas Inlets | 8 (Pre-treatment), 3 (Carrier), 8 (Pulse), 8 (Mixing) |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±1 °C |
| Heating Rates | 50–500 °C at 70 °C/min |
| Pressure Range | Atmospheric |
| Key Functions | TPD, TPR, TPO, TPRx, Pulse Chemisorption, Single-point BET, Breakthrough Curve Analysis |
| Gas Compatibility | He, Kr, N2, Ar, O2, H2, CO, CO2, NH3, H2O, NO, SO2, H2S, CH3OH, C2H5OH, Toluene, Benzene, and other reactive/volatile species |
| Thermal Conductivity Detector (TCD) | Quad-wire configuration with W–Re or gold-plated tungsten filaments |
| resolution | 1 μV |
| Mass Flow Controllers (MFCs) | 3–4 units |
| Sample Volume Capacity | 0–1 cm³ |
| Pulse Loop Volumes | 0.3 cm³, 1 cm³, or custom |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BELMASS II |
| Instrument Type | Chemisorption Analyzer with Integrated Online MS Detection |
| Gas Inlet Ports | Up to 16 |
| Temperature Stability | ±0.001 °C |
| Supported Techniques | TPD, TPR, TPS, Pulse Titration, BET Surface Area Analysis (via coupled gas dosing) |
| Mass Range | 1–200 amu |
| Detector | Faraday Cup / Continuous Dynode Electron Multiplier (C-SEM) |
| Minimum Detectable Concentration | <1 ppm (gas-dependent) |
| Scan Speed Options | Auto, 0.01–10 sec per amu (selectable) |
| Detection Channels | Up to 16 simultaneous mass channels |
| Sample Interface | Heated capillary transfer line (up to 300 °C), integrated dry scroll pump |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Model | BELPORE Series |
| Measurement Volume Range | 0.5–2 cm³ |
| Pressure Range | Vacuum to 414 MPa |
| Volume Measurement Accuracy | Better than 1% F.S. |
| Pressure Measurement Accuracy | Better than 0.1% F.S. |
| Maximum Data Points | 10,000 (intrusion) + 10,000 (extrusion) |
| Certified | CE, ISO 9001 |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELPYCNO L |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory Analyzer |
| Sample Type | Solids, Powders, Pastes, Liquids |
| Measurement Principle | Gas Displacement Pycnometry (Helium-Based) |
| Pressure Range | Vacuum to 2.5 bar |
| Temperature Control Range | 14–40 °C (Peltier-Driven, Optional) |
| Temperature Stability | ±0.01 °C |
| Density Accuracy | ±0.01% |
| Density Repeatability | ±0.01% |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Standard Sample Cell Volumes | 20 mL, 40 mL, 60 mL |
| Optional Sample Cell Volumes | 4 mL, 100 mL |
| Reference Cell Configuration | Three Integrated Reference Cells |
| Pressure Sensor | High-Stability Absolute Sensor (0–2.5 bar), 19-bit A/D, Drift ≤ ±0.02 mbar |
| Gas Options | He (standard), N₂, SF₆ |
| Inlet Pressure Range | 160–240 kPa (1.6–2.4 bar) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 4590, ASTM D6226-10 |
| Interface | RS-232 (COM) or USB |
| Dimensions (W×H×D) | 25 × 33 × 45 cm |
| Weight | 17 kg |
| Operating Environment | 15–30 °C, 20–80% RH |
| Power | 85–264 VAC, 50/60 Hz, 240 W |
| Brand | Microtrac |
|---|---|
| Model | BELPYCNO |
| Type | Benchtop True Density Analyzer for Solids |
| Measurement Principle | Gas Pycnometry (Helium/Nitrogen/SF₆) |
| Density Range | All Solid Materials |
| Density Accuracy | ±0.0001 g/cm³ |
| Repeatability | ±0.01% (RSD) |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Temperature Range | 15–35 °C (standard) |
| Pressure Range | Atmospheric to 150 kPa |
| Safety Features | Integrated pressure relief valve |
| Calibration Standards | Internal calibration spheres (multiple sizes) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 18857-1 |
| Software | BELPyCNOSoft v3.x with audit trail, user management, and 21 CFR Part 11 compliance options |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP HP |
| Pressure Range | Up to 20 MPa (optional: 13.5 MPa) |
| Pressure Sensor Options | 1, 1.5, 2, 3.5, 13.5, or 20 MPa (±0.08% F.S.) |
| Temperature Control Range | 4.2 K – 673 K (via liquid He/N₂ cryostats, resistive furnaces, Peltier units, and air-bath thermal management) |
| Gas Inlets | 6 total (1 He for dead-volume calibration, 1 compressed air, 4 adsorptive gases) |
| Vacuum System | Optional turbomolecular pump + vacuum gauges |
| Compliance | Built-in compressibility factor (Z) and virial coefficient correction for non-ideal gas behavior |
| Sealing | Swagelok® filter-faced ferrules (0.5 µm pore size) |
| Thermal Stability | Air-bath manifold & reference chamber (15–35 °C, ±0.1 °C) |
| Software | BELSIM™ (isotherm modeling, PCT analysis), optional BELDyna™ (kinetic modeling: concentration vs. time, effective diffusivity, mass transfer coefficients) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELSORP MAX G |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Volumetric Gas Adsorption (Dynamic & Static Mode) |
| Number of Analysis Stations | 3 or 6 |
| Operating Temperature Range | 10–35 °C |
| Storage Temperature Range | 0–50 °C |
| Temperature Control Accuracy | ±1 °C |
| Vacuum System | Dual-stage rotary vane pump, ultimate vacuum ≤1 × 10⁻³ mmHg (≤0.13 Pa) |
| Pressure Sensors | 1 Torr, 10 Torr, and 1000 Torr high-precision capacitance manometers |
| Minimum Detectable Pressure Change | <1 × 10⁻⁵ Pa |
| Free Space Calibration | AFSM™ (Automatic Free Space Measurement) patented technology |
| Isotherm Range | P/P₀ = 1 × 10⁻⁷ to 0.997 at 77 K (N₂) and 87 K (Ar) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MINI X |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption (Combined with Dynamic Pre-evacuation) |
| Analysis Stations | 4 |
| Surface Area Range | ≥0.01 m²/g (no upper limit) |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–133.3 kPa |
| Measurement Theory | Static Volumetric Method + Advanced Free Space Monitoring (AFSM™) |
| Compliance Options | FDA 21 CFR Part 11, IQ/OQ Documentation Package Available |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | NANOTRAC FLEX |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Reproducibility | ≤1% RSD |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C (with optional Peltier module) |
| Detection Method | Dynamic Light Backscattering (180° geometry) with full-range Mie theory-based data inversion |
| Sample Volume | as low as 2 µL |
| Sample Concentration Limit | up to 40 vol.% (non-dilutive measurement) |
| Zeta Potential Range | –3000 mV to +3000 mV (when coupled with STABINO ZETA) |
| Molecular Weight Estimation | via hydrodynamic diameter and Debye plot correlation |
| Optical Architecture | Fixed-focal-length fiber-optic probe with laser amplification detection |
| Data Processing Algorithm | Frequency Power Spectrum (FPS), not conventional Photon Correlation Spectroscopy (PCS) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | NANOTRAC WAVE II |
| Zeta Potential Range | ±200 mV |
| Temperature Operating Range | 0–90 °C (programmable ramp) |
| pH Resolution | 0.1 |
| Temperature Accuracy | ±0.1 °C |
| Particle Size Range | 0.3 nm – 10 µm |
| Concentration Range | 100 ppb – 40 % w/v |
| Detection Angle | 180° (backscatter) |
| Repeatability | ≤1% |
| Theoretical Basis | Full-range Mie theory with non-spherical particle correction factor |
| Compliance | ISO 13321, ISO 13099-2:2012, ISO 22412:2008 |
| Software Compliance | FDA 21 CFR Part 11 (electronic signatures, audit trail, user access control) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | S3500 Series |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Laser Diffraction) | 0.01–2,800 µm |
| Image Analysis Range | 0.75–2,000 µm |
| Repeatability | <1% |
| Measurement Time (Laser Diffraction) | 10–30 s |
| Measurement Time (Dynamic Image Analysis) | ~60 s |
| Light Source | Patented Triple-Solid-State Laser (Laser Diffraction) / High-Intensity Stroboscopic LED (Image Analysis) |
| Detection Angle Range | 0.02°–163° |
| Detector Array | 151 logarithmically spaced silicon photodiodes |
| Image Sensor | 5 MP, 2456 × 2058 resolution, 15 fps (optional high-speed camera available) |
| Software Compliance | Fully compliant with FDA 21 CFR Part 11 (audit trail, electronic signatures, data integrity controls) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | S3500SI |
| Measurement Principle | Laser Diffraction & Dynamic Image Analysis |
| Size Range (Laser Diffraction) | 0.01–2800 µm |
| Size Range (Dynamic Imaging) | 0.75–2000 µm |
| Repeatability | ±0.1% |
| Light Source | Triple Solid-State Red Lasers (635 nm) + High-Intensity Stroboscopic LED |
| Detector Array | 151 Logarithmically Spaced Silicon Photodiodes, Acceptance Angle: 0.02°–163° |
| Imaging Sensor | 5 MP CMOS, Resolution: 2456 × 2058 |
| Analysis Time (LD) | 10–999 s |
| Analysis Time (Imaging) | 60 s per field |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures, Data Integrity Controls |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | STABINO ZETA |
| Zeta Potential Range | ±3000 mV |
| pH Range | 1–14 |
| Operating Temperature Range | 0–90 °C |
| pH Resolution | ±0.1 |
| Temperature Resolution | ±0.1 |
| Measurement Principle | 180° Dynamic Light Scattering and Heterodyne Doppler Electrophoresis |
| Repeatability | ≤1% error |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | SYNC |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction + Dynamic Image Analysis Hybrid System |
| Measurement Range | 0.01–4000 µm |
| Repeatability | <1% |
| Measurement Time | 10–30 s |