Milestone
Filter
Showing all 16 results
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | duoPUR Ultra-High-Purity Acid Purification System |
| Principle | Sub-boiling Infrared Radiative Distillation |
| Throughput | 3000 mL in 8 h |
| Construction | High-Purity Fused Quartz Distillation Chamber |
| Automation | Motorized Acid Feed & Drain, Touchscreen HMI with Programmable Protocols |
| Safety | Dual Thermal Protection (Overheat & Dry-Run Prevention) |
| Compliance | Designed for ISO/IEC 17025-compliant trace-metal laboratories |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | ETHOS X |
| Extraction Principle | Microwave-Assisted Solvent-Free Microwave Extraction (SFME) |
| Capacity Options | 2 L, 5 L, 12 L (lab & pilot) |
| Typical Extraction Time | 5–8 min (first drop), ~40 min (complete yield) |
| Output Compatibility | Direct GC-MS injection without solvent removal |
| Compliance | Designed for GLP-compliant workflows |
| Software Interface | Touchscreen GUI with method storage, real-time power/temperature monitoring, and exportable extraction logs (CSV, PDF) |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | ETHOS X |
| Application | Rapid total fat determination in food and feed samples |
| Sample throughput | 15 positions |
| Sample mass range | 3–15 g |
| Total process time | ≤ 3 hours |
| Temperature control | Full-vessel infrared temperature monitoring |
| Automation | Integrated balance interface for automatic mass data import and calculation |
| Extraction methodology | Microwave-assisted acid hydrolysis coupled with solvent extraction |
| Stirring | Built-in magnetic stirring system |
| Compliance context | Designed to support AOAC 991.36, ISO 1443, and USP <467> workflows |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | Flexiwave |
| Application | Multi-mode Microwave-Assisted Synthesis |
| Operating Modes | Atmospheric, High-Pressure, Solid-State, Vacuum, Gas-Phase, Parallel, and Micro-scale Synthesis |
| Temperature Control | Dual-mode (Full-cavity IR + High-precision Fiber-optic) |
| Stirring | Integrated Automatic Magnetic Stirring |
| Reactor Orientation | Tilted Rotating Vessel |
| Cooling | Rapid Active Cooling System |
| Compliance | Designed for GLP/GMP environments |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | DMA-1 |
| Instrument Type | Portable |
| Measurement Principle | Catalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤0.1 ng |
| Linear Range | 0–1500 ng |
| Repeatability (RSD) | ≤1.0% |
| Linearity Error | ±10% |
| Sample Throughput | 2–5 min per analysis |
| Regulatory Compliance | EPA Method 7473, HJ 923–2017, GB 5009.17–2021 |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | DMA-80 evo |
| Principle | Catalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | 0.0002 ng |
| Linear Range | 0–30,000 ng |
| Repeatability (RSD) | ≤1.0% |
| Recovery Rate | >98.5% at 1000 ng |
| Compliance | EPA Method 7473, HJ 923–2017, GB 5009.17–2021 |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | ETHOS UP |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 1–44 vessels |
| Microwave Source | Dual Magnetron |
| Max Temperature | 320 °C |
| Max Pressure | 2200 psi |
| Microwave Leakage | 0.05 mW/cm² |
| Vessel Volume | up to 100 mL |
| Safety Certification | Integrated cast-metal cavity, self-sealing stainless-steel door, full-vessel real-time temperature & pressure monitoring |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | ETHOS X |
| Type | Microwave-Assisted Extraction (MAE) System |
| Sample Capacity | Up to 44 sealed vessels per run |
| Cycle Time | ≤40 min for full batch |
| Vessel Type | Disposable borosilicate glass extraction vessels |
| Temperature Control | Full-vessel infrared temperature monitoring |
| Safety Compliance | <0.05 mW/cm² microwave leakage (IEC 61000-3-2, IEC 62233), integrated stainless steel monolithic cavity, active pressure-relief “sliding wall” safety door |
| Solvent Compatibility | Polar (e.g., methanol, acetone), non-polar (e.g., hexane, DCM), and mixed solvents |
| Stirring | Integrated automatic magnetic stirring per vessel |
| Software | Preloaded method library, touchscreen GUI, audit-trail-capable operation log |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | PYRO SA |
| Instrument Type | Crucible Furnace |
| Max Temperature | 1200 °C |
| Temperature Control | PID-based dual-stage thermocouple system with DKD-traceable calibration |
| Max Power | 1200 W |
| Time to Max Temperature | ≤20 min |
| Heating Elements | Resistance wire, SiC rods, MoSi₂ rods |
| Internal Chamber Dimensions | 480 mm (W) × 550 mm (D) × 560 mm (H) |
| Acid Management System | Quartz-lined chamber, quartz condenser, PTFE/PFA acid traps, NaOH neutralization stage, corrosion-resistant PTFE vacuum pump (20 mbar, 40 L/min) |
| Airflow Design | Perforated honeycomb alumina ceramic wall for continuous oxidative airflow over crucibles |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | ultraWAVE 3 |
| Cavity Class | Industrial-grade |
| Sample Capacity | 1–22 samples per batch |
| Microwave Source | Single Magnetron |
| Max Temperature | 320 °C |
| Max Pressure | 3000 psi (207 bar) |
| Reaction Chamber Volume | 4.2 L |
| Sample Mass Capacity | ≥25 g per vessel |
| Acid Consumption | 2–3 mL per sample |
| Vessel Compatibility | Standard quartz, borosilicate glass, or TFM-lined tubes |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | UltraWAVE |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 1–22 samples |
| Microwave Source | Single Magnetron |
| Max Temperature | 320 °C |
| Max Pressure | 3000 psi (207 bar) |
| Reaction Chamber Volume | 4.2 L |
| Sample Mass Capacity | ≥25 g per vessel |
| Acid Consumption | 2–3 mL per sample |
| Vessel Compatibility | Standard quartz, borosilicate glass, or TFM-lined tubes |
| Automated Sealing/Unsealing Time | ~10 s per vessel |
| Pressure Relief | Fully automated and controlled |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | PYRO |
| Instrument Type | Crucible Furnace |
| Max Temperature | 1200 °C |
| Temperature Control | PID |
| Max Power | 1200 W |
| Ramp Time to Max Temp | 20 min |
| Heating Method | Resistance Wire / Silicon Carbide Rod / Molybdenum Disilicide Rod |
| Internal Dimensions | 480 mm × 550 mm × 560 mm (H) |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | subCLEAN |
| Instrument Type | Sub-Boiling Distillation Apparatus |
| Heating Method | Non-Contact Infrared Radiation |
| Distillation Capacity | 900 mL per 12 h |
| Purification Tube Material | PFA (Perfluoroalkoxy Alkane) |
| Control Interface | Intelligent Color Touchscreen Terminal with Programmable Protocols |
| Safety Features | Thermal Cut-Off Switch Preventing Overheating and Dry-Out |
| Automation | Automatic Acid Feeding and Drainage |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | SynthWAVE |
| Type | Single-Reactor-Chamber Pre-Pressurized Microwave Synthesis System |
| Operating Temperature | Up to 280 °C (with pre-pressurization) |
| Maximum Pressure | 200 bar |
| Pre-Pressurization Range | 40–100 bar (inert gas) |
| Reaction Volume Capacity | 1–600 mL |
| Microwave Frequency | 2.45 GHz |
| Power Output | Adjustable, up to 1600 W |
| Stirring | Dual-mode — high-torque mechanical stirring + optional magnetic stirring |
| In-situ Sampling | Yes, under full temperature/pressure conditions |
| Chamber Material | Fully passivated 316L stainless steel |
| Compliance | FDA 21 CFR Part 11–compliant software architecture, GLP/GMP-ready audit trail |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | TraceClean |
| Type | Automated Ultra-Trace Acid Cleaning System for Analytical Vessels |
| Compliance | Designed for ISO/IEC 17025 and GLP Laboratories |
| Application Scope | TFM, PFA, Quartz, and Fused Silica Vessels Used in ICP-MS, ICP-OES, and HR-ICP-MS Analysis |
| Acid Compatibility | HNO₃, HCl, HF (with optional corrosion-resistant configuration) |
| Cycle Time | ≤ 60 min per batch |
| Blank Performance | Sub-ppt metal contamination levels (e.g., <0.1 pg/mL Cr, Fe, Ni, Cu, Zn, Cd, Pb in rinsate) |
| Chamber Sealing | Motorized pneumatic lid with pressure-sensing interlock |
| Waste Handling | Integrated acid-resistant waste reservoir with level sensor and neutralization option |
| Exhaust Management | Built-in condenser-cooled fume extraction with HEPA + acid-scrubbing filter stack |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | UltraCLAVE |
| Category | Microwave Digestion Instrument for Sample Preparation |
| Chamber Type | Single Pre-Pressurized Reaction Chamber |
| Max Operating Temperature | Up to 300 °C |
| Max Operating Pressure | Up to 200 bar |
| Chamber Volume | 4.2 L |
| Sample Capacity | ≥25 g per vessel |
| Batch Throughput | ≥77 samples |
| Acid Consumption | 2–3 mL per sample |
| Vessel Compatibility | Standard quartz, borosilicate glass, and TFM-lined tubes |
| Automation | Fully automated sealing/unsealing and pressure release (<10 s per vessel) |
| Temperature Measurement Accuracy | ±0.5 °C (RTD-based) |
| Temperature Uniformity | ±2 °C across chamber volume |
| Pressure Control Stability | ±1 bar |
| Regulatory Compliance | Designed to support GLP/GMP workflows, audit-trail-ready software architecture compatible with FDA 21 CFR Part 11 requirements |