Neocera
Filter
Showing all 13 results
| Brand | Neocera |
|---|---|
| Origin | USA |
| Model | Combinatorial PLD System |
| System Type | Turnkey Pulsed Laser Deposition Platform with Continuous Composition Spread (CCS-PLD) Capability |
| Substrate Compatibility | 2-inch wafers (4-inch and 6-inch available on request) |
| Operating Environment | Up to 800 °C, up to 500 mTorr O₂ partial pressure |
| Deposition Mode | Standard PLD + CCS-PLD (Continuous Composition Spread) |
| Target Configuration | Multi-target carousel for binary/ternary/quaternary combinatorial synthesis |
| Film Architecture Support | Epitaxial thin films, multilayer heterostructures, superlattices |
| Oxygen Compatibility | Fully compatible with reactive oxygen ambient for metal oxide epitaxy |
| Post-deposition Annealing | Not required due to in-situ compositional grading and kinetic control |
| Maskless Operation | Enabled by angular deposition gradient and laser fluence modulation |
| Layer Resolution | Sub-monolayer precision per pulse cycle |
| Compliance | Designed for GLP-compliant thin-film R&D environments |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 180 PED |
| Quotation | Upon Request |
| Vacuum Chamber | 18" spherical chamber with 8" CF viewport, 6.75" CF PED source port, three 6" CF ports, two additional 2.75" and 1.33" CF ports |
| Electron Gun Energy | 8–20 keV |
| Pulse Energy | 100–800 mJ |
| Pulse Width | 100 ns |
| Max Repetition Rate | 10 Hz at 15 kV, 5 Hz at 20 kV |
| Beam Cross-Section (Min) | 8 × 10⁻² cm² |
| Peak Power Density | 1.3 × 10⁸ W/cm² |
| Z-Axis Alignment Range | 50 mm |
| XY Alignment Range | ±20 mm |
| Spark Plug Lifetime | ~3 × 10⁷ pulses |
| Substrate Heater | Ø2" max / 10×10 mm² min |
| Substrate Rotation | 1–30 RPM (360° continuous) |
| Target Carousel | 6 × 1" or 3 × 2" targets |
| Target Grid Scanning | Programmable raster ablation pattern |
| Target Height Adjustment | Motorized |
| Target Shutters | Individual shutters per target to prevent cross-contamination |
| Process Gas Compatibility | O₂, N₂, Ar |
| Pulse Energy Stability | ±10% |
| Base Pressure | ≤8 × 10⁻⁸ Torr (with dry pump + turbomolecular pump) |
| Software Platform | Windows 7 + LabVIEW 2013 |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ion-Assisted PLD System |
| Pricing | Upon Request |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Model | Large-Area PLD Systems |
| Substrate Diameter | 4" (100 mm), 6" (150 mm), 8" (200 mm) |
| Chamber Type | 18-inch-diameter spherical or cylindrical vacuum chamber |
| Max. Substrate Temperature | 850 °C (for 4″), 750 °C (for 6″), 700 °C (for 8″) |
| Target Mount | 4 × 2-inch rotary target assembly |
| Thickness Uniformity | ±5% or better across full wafer |
| Process Gases | O₂, N₂, Ar with mass flow controllers (MFCs) |
| Load Lock | Integrated |
| Automation Platform | Windows 7 + LabVIEW 2013 |
| Laser Scanning | Programmable beam rastering with inverse-velocity dwell-time compensation |
| Oxygen-Compatible High-Temperature Operation | Yes |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma EFI HiRes |
| Pricing | Upon Request |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma EFI |
| Pricing | Upon Request |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma SSM HiRes |
| Pricing | Available Upon Request |
| SQUID Spatial Resolution | 3 µm |
| HiRes Spatial Resolution | 250 nm |
| SQUID Scan Area | ≥100 mm × 100 mm |
| HiRes Scan Area | ≥100 mm × 100 mm |
| SQUID Current Sensitivity | 500 nA @ 333 µm, 1.5 µA @ 1000 µm |
| HiRes Current Sensitivity | 5 µA @ 2 µm, 100 µA @ 100 µm |
| SQUID Magnetic Field Sensitivity | 15 pT/√Hz (typ.) |
| HiRes Magnetic Field Sensitivity | 10 nT/√Hz (typ.) |
| SQUID Operating Frequency Range | DC–25 kHz |
| HiRes Operating Frequency Range | 10 kHz–200 kHz |
| SQUID Imaging Depth | ≤10 mm |
| HiRes Imaging Depth | <100 µm |
| Excitation Source | ±10 V @ 100 mA, DC–200 kHz |
| Optical Lens Resolution | 2 µm (NIR/Visible) |
| Power Supply | 110–120 V @ 20 A or 220–240 V @ 10 A |
| OS | Windows 10 64-bit |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma SSM |
| Pricing | Upon Request |
| Spatial Resolution (SQUID) | 3 µm |
| Scan Area (SQUID) | ≥100 mm × 100 mm |
| Current Sensitivity | 500 nA @ 333 µm |
| Magnetic Field Sensitivity | 15 pT/√Hz (typ.) |
| Imaging Depth | 10 mm |
| SQUID Operating Frequency Range | DC to 25 kHz |
| Function Generator | ±10 V @ 100 mA, DC to 200 kHz |
| Optical Lens Resolution | 2 µm (NIR/Visible) |
| Power Supply | 110–120 V @ 20 A or 220–240 V @ 10 A |
| OS | Windows 10 64-bit |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Pioneer 120 Advanced PLD System |
| Substrate Heating | Up to 850°C, Radiant Heater, O₂-Compatible |
| Substrate Size | 10 mm × 10 mm to 2-inch diameter |
| Vacuum Base Pressure | ≤5×10⁻⁹ Torr |
| Chamber Diameter | 12 inches |
| Target Capacity | 6×1″ or 3×2″ targets |
| Turbo Pump Speed | 260 L/s (software-controlled) |
| In-situ Diagnostics | RHEED-compatible |
| Load Lock | Optional |
| Software Platform | Windows 7 + LabVIEW 2013 |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Model | Pioneer 120 PLD System |
| Substrate Heater Type | Conductive (electrical) heating stage |
| Max Substrate Temperature | 950 °C |
| Heater Compatibility | O₂-compatible up to 1 atm (760 Torr) |
| Target Changer | Motorized, programmable multi-target rotator with rastering and position indexing |
| Vacuum System | Dry-pump stack — turbomolecular pump backed by diaphragm or scroll pump |
| Deposition Chamber Ports | 8" CF for pump, 8" CF for heater, 8" CF for target assembly |
| Laser Source | KrF excimer laser (248 nm) |
| Optical Path | 45° turning mirror, plano-convex lens (f ≈ 50 cm) |
| Control Software | Windows 7 + LabVIEW 2013 (integrated real-time control of heater, target rotation, pressure regulation, pump sequencing, and laser triggering) |
| Compliance | Designed for GLP/GMP-aligned thin-film R&D |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Model | Pioneer 180 Laser MBE/PLD System |
| Substrate Heating | 1000 °C (laser heater), 850 °C (radiant heater) |
| Substrate Size | 1 cm × 1 cm (laser-heated stage), 2″ diameter (radiant-heated stage) |
| Vacuum Chamber Diameter | 18″ |
| RHEED Gun Voltage | 30 keV |
| RHEED Operating Pressure | ≤500 mTorr (O₂) |
| Gas Flow Control | O₂/N₂ up to 100 SCCM |
| Software Platform | Windows 7 + LabVIEW 2013 |
| Target Mounting Options | 6 × 1″ or 3 × 2″ rotating target holder |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Model | Pioneer 180 MAPLE PLD System |
| Substrate Heating | Up to 500 °C with programmable controller |
| Substrate Size | Max. 2" diameter or multiple 1 cm × 1 cm samples |
| Substrate Rotation | 20 RPM |
| Vacuum Chamber Diameter | 18" |
| Target Stage | LN₂-cooled, single-target standard (multi-target optional) |
| Gas Flow Control | 50–100 SCCM MFC |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Model | Pioneer 180 PLD System |
| Vacuum Base Pressure | ≤5×10⁻⁹ Torr |
| Chamber Diameter | 18 in |
| Max Substrate Size | 6 in |
| Max Target Capacity | 6×1″ or 3×2″ |
| Substrate Heater | Radiant, O₂-compatible up to 1 atm (760 Torr) |
| Max Substrate Temperature | 850 °C (upgradable to 1000 °C) |
| Turbo Pump Speed | 400 L/s (software-controlled) |
| In-situ Diagnostics Support | RHEED, LAXS, IES |
| Load-Lock Compatible | Yes |
| Multi-Source Integration Options | PED, RF/DC Sputtering, DC Ion Gun |
| UHV Cluster Integration Ready | XPS, ARPES, MBE |