Netzsch
Filter
Showing 1–30 of 84 results
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | APTAC 264 |
| Temperature Range | RT to 500 °C |
| Temperature Tracking Rate | 0–400 °C/min |
| Minimum Detectable Heat Flow Rate | 0.002 °C/min |
| Pressure Range | 0–140 bar |
| Pressure Tracking Rate | 0–680 bar/min |
| Standard Functions | Integrated Stirring, Liquid Injection, and Effluent Discharge |
| Optional Feature | VARIPHI™ Thermal Inertia Compensation Technology |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | ARC 244 |
| Temperature Range | RT to 500 °C |
| Temperature Tracking Rate | 0–20 °C/min |
| Minimum Detectable Heat Flow Rate | 0.01 °C/min |
| Pressure Range | 0–200 bar |
| Optional Features | Integrated Stirring, Venting Module, VARIPHI™ Thermal Inertia Compensation Technology |
| Safety Architecture | Dual-Redundant Interlock System, Top-Lifting Furnace Assembly, Tubular Heater Design for Minimized Thermal Backflow |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | ARC254 |
| Temperature Range | RT to 500°C |
| Temperature Tracking Rate | 0–200°C/min |
| Minimum Detectable Heat Flow Rate | 0.01°C/min |
| Pressure Range | 0–200 bar |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter |
| Optional Accessories | VARIPHI™ Technology Module, Stirring/Injection/Emission Units, Battery Test Fixture, Nail Penetration Fixture for Li-ion Cells |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DEA 288 |
| Frequency Range | 0.001–1 MHz |
| Resistivity Measurement Range | 10⁰–10¹⁶ Ω·cm (sensor-dependent) |
| Data Channels | 1–16 (configurable) |
| Configuration Options | Portable Version or Industrial Rack-Mounted Version |
| Sensor Compatibility | In-mold, embedded, and lab-grade dielectric sensors |
| Environmental Test Capabilities | Compatible with heating/cooling stages, hot presses, humidity chambers, and UV irradiation systems |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Classic |
| Temperature Range | RT to 1600 °C |
| Heating Rate | 0–50 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±5000 µm |
| Resolution | 2 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Select |
| Temperature Range | −180 °C to 2000 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±10,000 µm / ±25,000 µm |
| Resolution | 1 nm / 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Force Control | Adjustable from 10 mN to 3 N (optional) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Supreme HT |
| Temperature Range | −180 to 2800 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±25,000 µm |
| Resolution | 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum (down to 10⁻⁵ mbar) |
| Furnace Types | Graphite, Alumina, Fused Silica |
| Optional Features | c-DTA® (calibrated Differential Thermal Analysis), Identify™ Spectral Matching, Rate-Controlled Sintering (RCS) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Supreme |
| Temperature Range | −180 to 2800 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±25,000 µm |
| Resolution | 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Force Control | Adjustable from 10 mN to 3 N (optional) |
| Sample Types | Solid, Powder, Liquid |
| Furnace Configurations | Single or dual interchangeable furnaces |
| Patented Technologies | NanoEye displacement sensor, MultiTouch sample positioning, c-DTA® (optional), Identify spectral library (optional), Rate-Controlled Sintering (RCS, optional) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DMA 303 Eplexor |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −170 °C to 800 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | 1 mN to 50 N |
| Displacement Range | 30 mm |
| Frequency Range | 0.001 Hz to 150 Hz |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 F1 Phoenix |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –180 °C to 700 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0 to 200 K/min |
| Sensor Options | τ-type (time constant 0.6 s), μ-type (high-sensitivity) |
| Cooling Options | Liquid nitrogen (LN₂), mechanical refrigeration (–85 °C to 600 °C), compressed air, cooling cup |
| Sample Capacity | Multi-sample capability (optional 64-position ASC auto-sampler) |
| Atmosphere Control | Integrated mass flow controller, gas-tight furnace design compatible with FTIR/MS coupling |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 HP Phoenix |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –150 °C to 600 °C (under vacuum to 15 MPa) |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–100 K/min |
| Pressure Range | 0–15 MPa (0–150 bar) |
| Atmosphere Compatibility | Static or dynamic O₂, N₂, Ar, He, H₂, CO₂, CH₄, and other process gases |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 214 Polyma |
| Temperature Range | −100 °C to 600 °C |
| Heating/Cooling Rate | up to 500 °C/min |
| Sensor Type | Corona® high-reproducibility heat-flux sensor |
| Crucible System | Concavus® concave-bottom crucibles with fixed annular contact geometry |
| Software Platform | Proteus® with Smart Mode, Expert Mode, TM-DSC, Beflat® baseline correction, Auto-Analysis, Identify™ polymer recognition database |
| Compliance | ISO 11357-1, ASTM E794, ASTM E1356, USP <1151>, GLP/GMP-ready audit trail (FDA 21 CFR Part 11 optional) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | DSC |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0 to 500 °C/min |
| Detection Limit | 0.1 μW |
| Atmosphere Control | Dynamic or static inert, reducing, or oxidizing (automated gas switching) |
| Cooling Options | Compressed air, mechanical refrigeration, liquid nitrogen (dual-cooling system optional, software-switchable) |
| Optional Accessories | Photo-DSC module, ASC automatic sample changer (20 positions), TMDSC upgrade |
| Software Features | Intelligent Mode, Expert Mode, Auto-Calibration, Auto-Analysis, Pattern Recognition, Tau-R® advanced thermal lag correction, DSC spectral database and search engine |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Classic |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −170 °C to 600 °C |
| Heating/Cooling Rate | 0.001–100 K/min |
| Temperature Accuracy | ±0.1 K (intrinsic) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Supreme-H |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | −180 °C to 750 °C |
| Heating/Cooling Rate | 0 to 200 K/min |
| Module Architecture | Interchangeable Multi-Module Platform |
| Compliance | GLP, GMP, FDA 21 CFR Part 11 (with optional software package) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris® Select-P |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –170 to 600 °C |
| Heating/Cooling Rate | 0 to 500 K/min |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (software-enabled), ISO 11357, ASTM E794, ASTM E1356 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | DSC |
| Temperature Range | −170 to 650 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Module Configuration | Sensor + Furnace Assembly (S-Module) |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (with optional software package) |
| Key Software Features | BeFlat®, Tau-R Correction, TM-DSC (optional), Automatic Baseline Subtraction, Crystallinity Calculation, Cp Measurement |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 3500 Sirius |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Sample Capacity (with ASC) | Up to 20 positions (samples + references) |
| Instrument Type | Differential Scanning Calorimeter |
| 炉 Body Material | Silver-based furnace block |
| Sensor Architecture | Monolithic sensor design |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F1 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Sensor Types | Replaceable DSC (−150 to 1650 °C) and DTA (up to 2000 °C) |
| Vacuum Capability | High-vacuum sealed system |
| Gas Control | Integrated stainless-steel gas lines with metal-encapsulated mass flow controllers (MFCs) |
| Optional Automation | Stepper-motor-driven dual-furnace configuration and 20-position auto-sampler |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F3 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | FRG Structural Adhesion Tester |
| Compliance | DIN EN 520 |
| Sample Dimensions (L × W × T) | 300 × 45 × 9.5 / 12.5 / 15.0 mm |
| Propane Purity | ≥95%, Operating Pressure: 4.0 bar |
| Device Dimensions (W × D × H) | 450 × 400 × 300 mm |
| Weight | 37 kg |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | NETZSCH GABO EPLEXOR |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –160 °C to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Static Force Range | up to 500 N (optional 1500 N) |
| Dynamic Force Range | ±25 N, ±100 N, ±150 N, or ±500 N |
| Displacement Range | 60 mm |
| Frequency Range | 0.01 Hz to 100 Hz (optional: 0.0001 Hz and 200 Hz) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | NETZSCH-GABO METER |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | RT to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Maximum Applied Force | 5000 N |
| Displacement Range | 50 mm |
| Frequency Range | 0.1–50 Hz |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | GHP456 Titan |
| Measurement Principle | Guarded Hot Plate Method |
| Applicable Standards | ISO 8302, DIN EN 12667, DIN EN 12939, DIN EN 13163, ASTM C177, GB 10294 |
| Temperature Range | −160 °C to 600 °C |
| Sample Dimensions | 300 mm × 300 mm (max thickness 100 mm) |
| Thermal Conductivity Range | 0–2 W/(m·K) |
| Accuracy | ±2% |
| Repeatability | ±1% |
| Vacuum Capability | Yes |
| Control Sensors | 29 Pt-100 resistance thermometers |
| Footprint (L×W×H) | 3000 mm × 1500 mm × 2000 mm |
| Operating Environment | Ambient temperature laboratory conditions |
| Sample Throughput | Multi-sample sequential testing supported |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | HBK Horizontal Burning Chamber |
| Compliance Standards | ISO 3795, DIN 75200, FMVSS 302, GB 8410, CMVSS 302, FAR 25.853 |
| Sample Dimensions | 356 × 100 × ≤13 mm |
| Fuel | ≥95% purity propane |
| Gas Pressure | 4.0 bar |
| Chamber Dimensions (W×D×H) | 385 × 210 × 365 mm |
| Weight | 26 kg |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | HFM 446 L Lambda |
| Measurement Principle | Heat Flow Method (ASTM C518, ISO 8301, DIN EN 12667) |
| Cold/Hot Plate Temperature Range | –20 °C to +90 °C |
| Temperature Setpoints | Up to 10 independent points |
| Sample Dimensions (L×W×H) | 600 mm × 600 mm × 200 mm (max) |
| Thermal Conductivity Range | 0.002 – 2.0 W/(m·K) |
| Thermal Resistance Range | 0.05 – 8.0 m²·K/W |
| Accuracy | ±1% (relative to NIST-traceable reference materials) |
| Repeatability | ≤0.5% (RSD, under controlled ambient and sample conditioning) |
| Applied Sample Pressure Range | 0 – 5 kPa (motorized, programmable load control) |
| Thickness Resolution | <1 µm (integrated high-precision micrometer displacement sensor) |
| Integrated Peltier Cooling System | Yes |
| Optional Modules | Specific Heat Capacity (Cp) measurement via dual-plate calorimetry mode |
| Overall Dimensions (L×W×H) | 1000 mm × 1000 mm × 1500 mm |
| Compliance | Fully compatible with GLP/GMP data integrity requirements |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Instrument Type | Heat Flow Meter (HFM) |
| Model | HFM 446 M Lambda |
| Dimensions (L×W×H) | 500 mm × 500 mm × 500 mm (sample chamber footprint) |
| Temperature Range (Hot/Cold Plate) | –20 °C to +90 °C |
| Temperature Points | Up to 10 programmable setpoints |
| Sample Size | Up to 300 mm × 300 mm × 100 mm (L×W×H) |
| Thermal Resistance Range | 0.05 to 8.0 m²·K/W |
| Thermal Conductivity Range | 0.002 to 2.0 W/(m·K) |
| Accuracy | ±1% |
| Repeatability | 0.5% |
| Maximum Sample Load Pressure | 21 kPa |
| Compliance | ASTM C518, ISO 8301, DIN EN 12667, GB/T 10294 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | Heat Flow Method |
| Dimensions (L×W×H) | 490 mm × 300 mm × 390 mm |
| Accuracy | ±1% |
| Thermal Conductivity Range | 0.002 – 2.0 W/(m·K) |
| Repeatability | 0.5% |
| Cold/Hot Plate Temperature Range | −20 °C to +90 °C |
| Temperature Setpoints | 10 |
| Sample Size Max | 200 mm × 200 mm × 50 mm |
| Thermal Resistance Range | 0.05 – 8.0 m²·K/W |
| Maximum Sample Load | 21 kPa |
| Optional Features | SMART MODE, Specific Heat Measurement Module, High-Conductivity Extension Kit |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | HMOR422 |
| Temperature Range | RT to 1450°C (optional up to 1500°C) |
| Sample Dimensions | 125 × 25 × 25 mm (standard) |
| Load Capacity | 1 N to 5000 N |
| Loading Rate | 1.25 N/s to 125 N/s (4 selectable steps) |
| Test Atmosphere | Air |
| Feed Mechanism | Continuous feed with preheating zone |
| Bending Mode | Three-point bending (standard) |
| Deformation Measurement | Differential high-precision displacement system (compatible with RUL/CIC421 architecture) |
| Compliance | ISO 5013 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | KBK Flammability Test Chamber |
| Compliance | EN ISO 11925-2 |
| Sample Dimensions | 250 × 90 × ≤60 mm |
| Fuel | Propane (≥95% purity) |
| Gas Pressure | 4.0 bar |
| Airflow Velocity Accuracy | ±0.1 m/s |
| Operating Temperature | +23 ± 5 °C |
| Chamber Dimensions (W×D×H) | 700 × 400 × 980 mm |
| Construction Material | Corrosion-Resistant Stainless Steel |
| Viewing Windows | Dual Large-Sized Fire-Rated Glass Doors |
| Adjustable Sample Holder | Horizontal & Vertical Positioning |