| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet Air |
| Volume Range Options | 0.1–2 µL (Gray), 0.5–10 µL (Pink), 2–20 µL (Beige), 10–100 µL (Orange), 20–200 µL (Yellow), 100–1000 µL (Blue), 500–5000 µL (Green), 1000–10000 µL (White) |
| Increment Resolution | 0.002–10 µL (model-dependent) |
| Operating Principle | Air-displacement positive displacement hybrid mechanism with low-force plunger actuation |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet FII & VII |
| Type | Manual Single-Channel Adjustable-Volume Pipette |
| Volume Range | 10–1000 µL |
| Accuracy | ±0.5% to ±1.2% (varies by volume) |
| Coefficient of Variation (CV) | ≤0.2% to ≤0.6% (volume-dependent) |
| Tip Compatibility | BMT2-series and F-series sterile filtered tips (e.g., BMT2-SG, FSGRB, BMT2-LE, FLERB) |
| Operating Principle | Air-displacement positive displacement (FII: fixed-volume |
| VII | triple presettable volumes) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | ACCUPENSER JR |
| Instrument Type | Manual Adjustable Bottle-top Dispenser |
| Automation Level | Manual |
| Volume Range Options | 0.2–10 mL (AJ-1), 0.4–20 mL (AJ-2), 1–50 mL (AJ-5), 2–100 mL (AJ-10) |
| Minimum Increment | 0.05 mL (AJ-1), 0.1 mL (AJ-2 & AJ-5), 0.25 mL (AJ-10) |
| Coefficient of Variation (CV) | ≤0.1% |
| Bottle Compatibility | Standard 500 mL and 1 L reagent bottles (neck dimensions identical) |
| Bottle Dimensions (W × H, mm) | 75 × 210 (165), 100 × 210 (165), 146 × 210 (165) — values in parentheses indicate collapsed height when vernier head is folded |
| Materials in Contact with Liquids | Chemically resistant polymers |
| Sterilization | Autoclavable at 121°C for 20 minutes |
| Compliance | Designed to support GLP-compliant workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Custom-Made Pipettes |
| Instrument Type | Single-Channel Manual Pipette |
| Automation Level | Manual |
| Channel Count | Single |
| Volume Range | Custom-Defined (Typically 0.1–10,000 µL) |
| Accuracy & Precision | Compliant with ISO 8655 (per customer-specified calibration range) |
| Regulatory Compliance | Designed to support GLP/GMP workflows and FDA 21 CFR Part 11–aligned documentation protocols |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Dispet Ex |
| Dispensing Range | 0.2–10 mL (DP-10), 0.4–20 mL (DP-20), 1–5 mL (DP-5), 2–10 mL (DP-10) |
| Minimum Increment | 0.05–0.25 mL |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤0.2% |
| Bottle Compatibility | Ø22 mm (for DP-5/DP-10), up to Ø45 mm (with optional adapters) |
| Adapter Options | DP-1118 (18 mm), DP-1119 (19 mm), DP-1122 (22 mm), DP-1124 (24 mm), DP-1125 (25 mm), DP-1128 (28 mm), DP-1133 (33 mm), DP-1138 (38 mm), DP-1145 (45 mm) |
| Included Accessories | One 220 mm flexible PTFE-lined tubing (user-cuttable) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET EX II |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28, GL-32, GL-45 (bottles sold separately) |
| Liquid Contact Materials | Chemically resistant PTFE, FEP, and ETFE components |
| Design | Handheld, portable, ergonomic manual dispenser |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET EX II |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.2–10 mL |
| Minimum Graduation | 0.05 mL |
| Accuracy | ±0.1% of full scale |
| Maximum Permissible Error | ±0.5% of set volume |
| Pressure Resistance | Up to 6 bar |
| Temperature Resistance | Up to 120 °C |
| Material Compatibility | Chemically resistant PTFE, FFKM, and glass-reinforced PPS components |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET Mini |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28 standard thread |
| Liquid Contact Materials | Chemically resistant PTFE, ETFE, and FEP components |
| Regulatory Compliance | Designed for ISO 8655-compliant volumetric dispensing procedures |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL2100DG |
| Type | Manual Multi-Channel Continuous Dispenser |
| Dispensing Range Options | 0.2–1.0 mL (00-21DG-1), 0.4–2.0 mL (00-21DG-2), 1.0–5.0 mL (00-21DG-5), 2.0–10.0 mL (00-21DG-10) |
| Minimum Increment | 0.01–0.10 mL depending on model |
| Display Resolution | 0.01 mL (DG-1/DG-2), 0.02 mL (DG-5), 0.10 mL (DG-10) |
| Fluid Contact Materials | PTFE, Tygon® tubing, polypropylene, Pyrex® glass, ceramic, platinum-iridium alloy |
| Housing | Impact-resistant polymer shell protecting internal glass and piston components |
| Ergonomics | Single-hand operation, lightweight design (<300 g) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL3100 |
| Pipette Type | Manual Multi-Channel Pipette |
| Volume Range Options | 0.2–1.0 mL, 0.4–2.0 mL, 1.0–5.0 mL, 2.0–10.0 mL |
| Minimum Increment | 0.1 mL (for 0.2–1.0 & 0.4–2.0 mL ranges), 0.5 mL (for 1.0–5.0 & 2.0–10.0 mL ranges) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Tip Compatibility | Nichiryo Standard Clear Tips (00-MPT-1, 00-MPT-2, 00-BMT2-X, 00-BMT2-Z) |
| Piston Material | PTFE-Coated Stainless Steel |
| Tip Packaging | 1000 or 2000 per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL5100 |
| Pipette Type | Single-Channel Manual Pipette |
| Adjustable Volume Range | 15–25 mL and 30–50 mL (via interchangeable volume adjustment tubes) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Compatible Tip Type | Nichiryo TL50 Series (e.g., 00-51TL50) |
| Tip Packaging | 50 pcs per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8100 |
| Type | Motorized Multi-Step Electronic Dispenser |
| Sample Volume Range | 1 µL – 5 mL (configurable via 7 interchangeable syringe barrels) |
| Accuracy | ±0.8% to ±2.5% (volume-dependent) |
| Precision (CV) | ≤0.3% to ≤4.0% (volume-dependent) |
| Max. Dispensing Cycles per Fill | 10–58 (barrel-dependent) |
| Sterilization | Autoclavable at 121 °C for 20 min (all barrels except 3.0 mL and 60 mL) |
| Syringe Tip Length | 50 mm |
| Materials | PP (standard), PE (N3 and Z barrels) |
| Drive Mechanism | Pulse-driven positive displacement |
| Compliance | Designed for GLP-compliant liquid handling workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8800 |
| Instrument Type | Multi-Channel Manual Continuous Dispenser |
| Number of Channels | 8 |
| Operating Range | 10–100 µL (6 preset volumes: 10, 20, 25, 40, 50, 100 µL) |
| Accuracy | ±2.0% (at specified volumes) |
| Coefficient of Variation (CV) | ≤1.2% |
| Syringe Options | A (520 µL), B (1300 µL) |
| Max. Sequential Dispensing Cycles | 50 (at 10 µL), 25 (at 20/25 µL), 12 (at 40/50/100 µL) |
| Dimensions (with syringes installed) | 285 × 82 × 23 mm |
| Sterilization Compatibility | Autoclavable at 121°C for 20 min |
| Actuation | Manual lever-driven continuous dispensing |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | NPLO2 |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.5 µL – 50 mL (via interchangeable syringe barrels) |
| Accuracy | ±0.3% to ±5% (volume-dependent) |
| Precision (CV) | <0.2% to <8.0% (volume-dependent) |
| Sterilizable Options | Yes (selected syringe barrels) |
| Compatible Tips | BMT-UT tips (NS-V), NS-ASP adapters (NS-Y/Z), Eppendorf 4780-compatible syringes |
| Syringe Material | Polypropylene (barrel), Polyethylene (plunger) |
| Max Sequential Dispensing Cycles | 48 |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet ECO |
| Pipette Type | Single-channel Manual Pipette |
| Volume Range | 20 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±3.0% to ±6.0% |
| Precision (CV) | ≤3.0% to ≤6.0% |
| Tip Compatibility | Nichiryo Glass Tips (S, L, X, Z series) |
| Operating Principle | Air-displacement with ceramic piston and PTFE-coated tip cone |
| Sealing | Dual O-ring tip ejection mechanism |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | EX II MULTI |
| Pipette Type | Manual Multi-Channel Pipette |
| Channels | 8 or 12 |
| Volume Range Options | 0.5–10 µL (V), 5–100 µL (S), 20–200 µL (L), 30–300 µL (K) |
| Minimum Increment | 0.01 µL (V), 0.1 µL (S), 0.2 µL (L), 1 µL (K) |
| Sterilization | Full-unit autoclavable at 121°C for 20 min |
| Tip Compatibility | BMT2-UT/UTWR/UTWRB, FUT/FUTRB, BMT2-SG/SGR/SGRB, FSE/FSERB, FAG/FAGRB, BMT2-K/KR/KRB |
| Material | UV-resistant polymer housing |
| Weight Reduction | ~30% vs. previous generation |
| Ergonomic Design | Rotatable 360° plunger knob, reduced plunger force, serviceable modular construction |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX II |
| Type | Manual Single-Channel Pipette |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Sterilization | Autoclavable at 121°C for 20 min |
| Tip Ejection | Non-contact, plastic ejector mechanism |
| Sealing Material | PTFE in air-tight components |
| Piston Material | Ceramic (for ≥200 µL models) |
| Filter Tip Compatibility | Integrated filter sleeve (≥1000 µL models) |
| Volume Adjustment | Digital dial with lockable knob |
| Minimum Increment | 0.002–10 µL (model-dependent) |
| Tip Compatibility | BMT2-series tips (UT, SS, SG, LE, X, Z) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX Plus II |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Tip Compatibility | BMT2-series (UT, SS, SE, L, X, Z) |
| Sterilization | Autoclavable (121°C, 20 min) & UV-Capable |
| Calibration | In-lab adjustable via integrated locking dial |
| Piston Material | Ceramic (≥100 µL), Fluoropolymer-coated stainless steel (≤10 µL) |
| O-rings | FKM (fluoroelastomer) |
| Spring | Corrosion-resistant alloy |
| Chemical Resistance | Verified against strong acids, bases, ketones, esters, aldehydes, and inorganic/organic solvents |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | NSS-1000II Basic |
| Type | Benchtop Robotic Liquid Handler |
| Configuration | Standalone or Integrated Platform |
| Programming Interface | C-language or Visual Basic SDK |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Application Scope | Life Sciences, Pharmaceutical R&D, Clinical Diagnostics, Chemical Laboratories |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Pipette Mate NEO |
| Power Source | Rechargeable Lithium-Ion Battery (Charging Time: 4 h |
| Input Voltage | 100–240 V, 50/60 Hz, 0.2 A |
| Filter | Hydrophobic PTFE, 20 mm × 0.2 µm |
| Compatible Pipettes | 1–100 mL glass or plastic serological pipettes |
| Sterilization | Autoclavable at 121 °C for 20 min (liquid-contact components only) |
| Weight | 167 g |
| Certifications | CE, RoHS |
| Operating Environment | Compatible with laminar flow hoods and UV sterilization workflows |
| Ergonomics | Integrated speed control dial, vertical stand-alone design (no support rack required) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Type | Sterilizable Disposable Pipette Tips |
| Packaging Options | Bulk (1000 pcs) and Rack (96-well or 50-well formats, sterilized or non-sterilized) |
| Volume Range | 0.1–10 µL, 0.5–10 µL, 2–200 µL, 50–300 µL, 100–1000 µL, 1000–5000 µL, 1000–10000 µL |
| Material | High-purity polypropylene (PP) |
| Sterilization | Autoclavable at 121 °C for 20 minutes |
| DNase/RNase-Free | Yes (except X and Z series) |
| UV-Compatible | Yes |