OEM
Filter
Showing 31–60 of 135 results
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| IP Rating Coverage | IPX5, IPX6, IPX7 |
| Compliance Standards | IEC 60529, ISO 20653, GB/T 4208, MIL-STD-810H Method 506.7, GJB 150.8A, IEC 60068-2-68, GB/T 2423.38, IEC 60034-5, GB/T 4942.1 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT+10°C to 50°C |
| Humidity Range | 85–98% RH |
| Temperature Uniformity | ≤2°C |
| Temperature Fluctuation | ±0.5°C |
| SO₂ Concentration Range | 0.1–1% v/v |
| Gas Delivery Method | Pressurized Cylinder System |
| Chamber Interior Material | PVC Plastic Sheet |
| Exterior Casing Material | Reinforced PVC Rigid Board |
| Viewing Window | Transparent Impact-Resistant Acrylic Lid |
| Sealing Method | Water-Tight Gasket Seal |
| Heating Method | Immersed Water-Bath Heater in Inner Tank |
| Standard Compliance | GB/T 9789–1988, DIN 50018, ISO 6988 (referenced) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | −70°C to +180°C |
| Thermal Transition Time (5 min) | ≤15 s (air-to-air) |
| Recovery Time (after door opening) | ≤3 min |
| Control System | TEMI880 color touchscreen PLC controller (English/Chinese switchable) or TEMI300 membrane-key programmable controller (English only) |
| Refrigeration | Twin-stage or cascade refrigeration system with original French Tecumseh/Tecumseh-derived hermetic compressor |
| Heating | Nickel-chromium alloy wire heater |
| Humidification | Surface evaporation type |
| Air Circulation | Wide-band forced convection via centrifugal blower (top discharge / bottom intake) |
| Insulation | Polyurethane rigid foam (≥100 mm) + ultra-fine glass fiber |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Chamber Material | Cold-rolled steel with electrostatic powder coating or optional SUS304 brushed finish |
| Door Seal | Dual-layer high-temp/low-temp resistant silicone rubber gasket |
| Standard Ports | One Ø50 mm test port (left side), dual-pane tempered observation window, two adjustable sample racks, fluorescent interior lighting, four swivel casters, integrated humidifier tank, RS485/RS232 communication interface |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB Shanghai) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| Temperature Range | Hot Zone: RT to +200 °C |
| Cold Zone | RT to −70 °C |
| Test Zone | +60 °C to +150 °C (Hot Shock), 0 °C to −65 °C (Cold Shock) |
| Switching Mechanism | Pneumatic Air-Door Isolation (Static Specimen) |
| Recovery Time | <5 min |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Refrigeration | Dual-Stage Cascade System (R404A/R23), Water-Cooled, German Semi-Hermetic Compressors |
| Construction | Interior – Mirror-Finish SUS304 Stainless Steel |
| Insulation | High-Density Fire-Retardant PU Foam |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–2002, GJB 150.3–1986 / 150.4–1986 / 150.5–1986, IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, EIA-364-32, QC/T 17–1992 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,100 (FOB) |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20–98% RH |
| Control Accuracy | ±0.5 °C / ±2.5% RH |
| Uniformity | ±1.5 °C / ±3% RH |
| Ramp Rate (Typical) | 1–3 °C/min (air average, unloaded, 25 °C ambient) |
| Compliance | GB/T 5170.2–1996, GB/T 5170.5–1996, GB 2423.1–1989, GB 2423.2–1989, GB 2423.22–1987, GB 10589–1989, GB 10592–1989, GB 11158–1989 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Chamber Configuration | Two-Zone or Three-Zone Thermal Shock System |
| Internal Volume Options | 49 L / 80 L / 150 L / 225 L |
| Temperature Range | High Zone: RT to +200 °C |
| Low Zone | RT to −70 °C |
| Test Zone | Thermal Shock from +60 °C to +150 °C (Hot Soak) and 0 °C to −65 °C (Cold Soak) |
| Switching Mechanism | Pneumatic Air-Door Isolation (Static Specimen) |
| Recovery Time | ≤5 min |
| Temperature Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration | Dual-Stage Cascade System with Semi-Hermetic German Compressors |
| Refrigerants | R404A (HT Stage) / R23 (LT Stage) |
| Insulation | High-Density Fire-Retardant PU Foam (≥150 mm Thickness) |
| Interior Material | Mirror-Finish SUS304 Stainless Steel |
| Exterior | SUS304 Stainless Steel or Powder-Coated Steel |
| Cooling Water Requirement | External 10 m³/h Closed-Loop Cooling Tower (User-Supplied) |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| External Dimensions (W×H×D) | 145×180×140 cm to 190×170×270 cm |
| High-Temp Reservoir Range | RT to +200 °C |
| Low-Temp Reservoir Range | RT to −70 °C |
| Test Zone Temperature Range | Hot Shock (+60 °C to +150 °C) |
| Switching Mechanism | Pneumatic Air-Damper–Actuated Static Specimen Method |
| Preheat Time (RT → 150 °C) | ≈30 min |
| Precool Time (RT → −70 °C) | ≈85 min |
| Recovery Time | <5 min |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Refrigeration System | Dual-Stage Cascade with Semi-Hermetic German Compressor (R404A/R23) |
| Inner Chamber Material | Mirror-Finish SUS#304 Stainless Steel |
| Outer Chamber Material | SUS#304 Stainless Steel or Powder-Coated Steel |
| Insulation | High-Density Fire-Retardant PU Foam |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 2,650 (FOB) |
| Temperature Range | −40°C to +150°C |
| Humidity Range | 20%–98% RH |
| Control Accuracy | ±0.5°C / ±2.5% RH |
| Uniformity | ±1.5°C / ±3% RH |
| Ramp Rate (Typical) | 3–5°C/min (air average, unloaded, 25°C ambient) |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Refrigerant | R404A (CFC-free) |
| Compressor | Tecumseh/Taikang hermetic scroll type |
| Noise Level | <60 dB(A) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1:2022, IEC 60068-2-2:2022, GJB 1032A–2021, MIL-STD-2164A–2018 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Controller Options | TEMI880 Color Touchscreen (EN/CN Switchable) or TEMI300 Membrane Keypad (English Only) |
| Protection Systems | Compressor Overheat/Overcurrent/High-Pressure, Dry-Heater Burnout Prevention, Chamber Over-Temperature, Low-Water Detection |
| Standard Features | Dual-Layer Tempered Glass Viewing Window, φ50 mm Cable Port (Left Side), Two Adjustable Sample Racks, Fluorescent Interior Lighting, Four Casters with Brakes, Removable Humidity Water Tank, RS485/RS232 Communication Interface, PC-Based Control Software |
| Temperature Control | Balanced Temperature & Humidity Control System (BTSC) |
| Operating Ambient | +5°C to +35°C |
| Heating | Nickel-Chromium Alloy Wire Heaters |
| Humidification | Surface Evaporation Type |
| Air Circulation | Wide-Range Forced Convection (Top-Down Flow), Multi-Blade Centrifugal Fan |
| Condensation | Air-Cooled |
| Refrigeration | Original French Tecumseh Hermetic Compressor |
| Refrigeration Circuit | Twin-Stage or Single-Stage Low-Temperature Loop Design |
| Construction | Outer Shell – SUS304B Stainless Steel |
| Airflow Uniformity | ±0.5°C Temp Deviation Across Working Volume (per IEC 60068-3-5) |
| Recovery Time | ≤3 min After Door Opening (from −40°C to +85°C at 50% RH) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| Temperature Range | High Zone: RT to +200°C |
| Low Zone | RT to −70°C |
| Test Zone | +60°C to +150°C (hot shock), 0°C to −65°C (cold shock) |
| Transfer Mechanism | Pneumatic air-door switching (stationary test specimen) |
| Recovery Time | <5 min |
| Temperature Uniformity | ±2.0°C |
| Control Accuracy | ±0.5°C |
| Refrigeration | Dual-stage cascade system with semi-hermetic German compressors |
| Refrigerant | R404A/R23 |
| Insulation | High-density fire-retardant PU foam |
| Interior Material | Mirror-finish SUS304 stainless steel |
| Exterior | SUS304 or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| Temperature Range | High Zone: RT to +200 °C |
| Low Zone | RT to −70 °C |
| Test Zone | +60 °C to +150 °C (hot shock) |
| Switching Method | Pneumatic damper–actuated air valve |
| Recovery Time | <5 min |
| Temp. Uniformity | ±2.0 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Refrigeration | Dual-stage cascade system with semi-hermetic compressors (R404A/R23) |
| Construction | Interior—SUS304 mirror-finish stainless steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 13,500–14,800 (FOB) |
| Control System | Siemens S7-1200 PLC + 10.1″ Color TFT Touchscreen HMI |
| Temperature Setpoint Accuracy | ±0.1 °C |
| Temperature Indication Accuracy | ±0.1 °C |
| Sensor | PT100 Class A Platinum Resistance Thermometer (DIN EN 60751) |
| Heating | Independent Nickel-Chromium Alloy Heaters (PID-controlled) |
| Refrigeration | Dual-stage Cascade Refrigeration System with Tecumseh/Tecumseh-derived Hermetic Compressors |
| Air Circulation | Low-Noise, High-Torque AC Inverter-Driven Motor + Multi-Blade Centrifugal Impeller |
| Internal Dimensions | 600 × 500 × 500 mm (W×H×D) |
| External Dimensions | 1500 × 2100 × 2250 mm (W×H×D) |
| Chamber Construction | AISI 304 Stainless Steel (Interior & Exterior), Matte-Finish Surface |
| Insulation | 120 mm Thickness — Hybrid Layer of High-Density Mineral Wool + Rigid Polyurethane (PU) Foam (λ ≤ 0.022 W/m·K) |
| Door Sealing | Dual-Lip High-Tensile Silicone Packing (Rated for −200 °C to +400 °C) |
| Transition Mechanism | Pneumatic Actuated Dual-Zone Partition with Active Thermal Isolation Valves |
| Sample Zone Configuration | Static Single-Chamber Mode or Dynamic Two-Zone Switching Mode |
| Recovery Time (from −20 °C to +85 °C) | ≤ 3.5 min (per IEC 60068-3-5) |
| Linear Ramp Rate | Up to 15 °C/min (programmable, load-dependent) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | MIL-STD-810G Method 506.6, IEC 60529 IPX1–IPX6, GB/T 4208, GB/T 2423.38, GJB 150.8 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-100 |
| Load Capacity | 100 kg |
| Test Table Dimensions (L×W) | 120 × 100 cm |
| Vibration Mode | Reciprocating (Linear Sine) |
| Speed Range | 60–300 rpm |
| Peak-to-Peak Amplitude | 25.4 mm |
| Frequency Range | 1.0–5.0 Hz (equivalent to 60–300 CPM) |
| Timer Range | 0.1 s – 999.99 h |
| Drive System | AC Variable-Frequency or DC Speed Control |
| Power Supply | 220 V, 50/60 Hz (single-phase) |
| Compliance | ISTA 3A, ISTA 3E, EN 71-1, ASTM D999, ASTM D3580, ISO 13355, ISO 2247 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-100 |
| Price | USD 5,200 (FOB) |
| Load Capacity | 100 kg |
| Test Table Dimensions (L × W) | 120 × 100 cm |
| Vibration Mode | Reciprocating (Linear Oscillation) |
| Speed Range | 60–300 rpm |
| Peak-to-Peak Amplitude | 25.4 mm |
| Frequency Range | 1.0–5.0 Hz |
| Timer Range | 0.1 s – 999.99 h |
| Drive System | AC Variable-Frequency Motor |
| Power Supply | 220 V, 50/60 Hz |
| Compliance | ISTA 3A, ISTA 3E, ASTM D999, EN 71-1, ISO 8766 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-100 |
| Price | USD 5,280 (FOB) |
| Load Capacity | 100 kg |
| Table Dimensions (L×W) | 120 × 100 cm |
| Vibration Mode | Reciprocating (Linear Horizontal) |
| Speed Range | 60–300 rpm |
| Peak-to-Peak Amplitude | 25.4 mm |
| Frequency Range | 1.0–5.0 Hz |
| Timer Range | 0.1 s – 999.99 h |
| Drive System | AC Variable-Frequency Motor |
| Power Supply | 220 V, 50/60 Hz |
| Compliance | ISTA 1A, ISTA 2A, ASTM D999, EN 71-1, ISO 8766 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-100 |
| Price | USD 5,280 (FOB) |
| Load Capacity | 100 kg |
| Table Dimensions (L×W) | 120 × 100 cm |
| Vibration Mode | Reciprocating (Linear Horizontal) |
| Speed Range | 60–300 rpm |
| Peak-to-Peak Amplitude | 25.4 mm |
| Frequency Range | 1.0–5.0 Hz |
| Timer Range | 0.1 s – 999.99 h |
| Drive System | AC Variable-Frequency Motor |
| Power Supply | 220 V, 50/60 Hz |
| Compliance | ISTA 3A, ISTA 3E, ASTM D999, EN 71-1, ISO 8766 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-CY-100 |
| Temperature Range | 25–80 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | 7-inch color touchscreen + Siemens PLC |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Non-dispersive UV absorption sensor (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-DL-150 |
| Drop Height Range | Adjustable up to 1500 mm |
| Height Accuracy | ±2% or ±10 mm (whichever is greater) |
| Drop Orientation | Face, Edge, Corner |
| Frame Structure | Single-arm, Dual-column |
| Actuation | Electromechanical lift & release |
| Cushioning System | Hydraulic damping buffer |
| Impact Angle Tolerance | ≤5° relative to base plate |
| Compliance | GB/T 4857.5, GB/T 4857.1–4857.2, GB/T 4857.17–4857.18, ISO 2248:1985 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-DL-150 |
| Price | USD 1,700 (FOB) |
| Compliance | GB/T 4857.5, GB/T 4857.1–4857.18, ISO 2248:1985 |
| Drop Height Accuracy | ±2% or ±10 mm |
| Structural Configuration | Single-arm, dual-column |
| Drop Orientation | Face, Edge, Corner |
| Height Display | Digital counter with rotary encoder feedback |
| Actuation | Electromechanical release with motorized lift & reset |
| Impact Base | Reinforced steel platform with hydraulic damping system |
| Maximum Load Capacity | 150 kg |
| Height Range | 300–1500 mm (adjustable in 10-mm increments) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-DL-150 |
| Max Load Capacity | 100 kg |
| Drop Height Range | 30–200 cm |
| Specimen Dimensions (Max) | 80 × 80 × 100 cm |
| Impact Base Plate | 170 × 120 × 15 cm |
| Overall Dimensions | 170 × 120 × 232 cm |
| Power Supply | 220 V, 1-Phase, 9 kW |
| Height Measurement Accuracy | ±2% or ±10 mm |
| Angular Deviation of Impact Surface vs. Base Plane | ≤5° |
| Compliance | GB/T 4857.5, GB/T 4857.1, GB/T 4857.2, GB/T 4857.17, GB/T 4857.18 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Chamber Internal Dimensions (D×W×H) | 900 × 600 × 500 mm |
| External Dimensions (D×W×H) | 1410 × 880 × 1280 mm |
| Heating Power | 1.3–1.8 kW |
| Temperature Range | +5°C to +55°C |
| Humidity Range | 85–95% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Continuous or Cyclic Programmable |
| Timer Range | 1 sec to 999 hours, minutes, seconds |
| Heating System | U-shaped titanium alloy high-speed immersion heater |
| Temperature Controller | Intelligent PID microcomputer controller with ±0.1°C control accuracy |
| Sensor | PT100 platinum resistance thermometer |
| Viewing Window | Full-transparent impact-resistant acrylic lid with water-sealed gasket |
| Sealing | Water-trap sealing between lid and chamber body |
| Lid Actuation | Pneumatic support struts |
| Interior Lining | PVC plastic board |
| Exterior Casing | Reinforced rigid PVC sheet (UV-stabilized, corrosion-resistant) |
| Included Accessories | One SO₂ gas cylinder (standard 40L, 15 MPa rated), regulator, and delivery tubing |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-HH- |
| Price | USD 2,700 (FOB China, ex-factory reference only) |
| Temperature Range | -70°C to +150°C |
| Humidity Range | 20–98% RH (optional 5–98% RH) |
| Temp. Uniformity | ±0.5°C |
| Humidity Uniformity | ±2.5% RH |
| Temp. Fluctuation | ±2.0°C |
| Humidity Fluctuation | +2–3% RH |
| Resolution | 0.1°C / 0.1% RH |
| Ramp Rate | +4.0°C/min (heat-up), -1.0°C/min (cool-down) |
| Internal Dimensions (typical) | 60×85×80 cm (W×D×H) |
| External Dimensions (typical) | 160×190×155 cm (W×D×H) |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Test Port | Ø50 mm × 1 (stainless steel SUS304) |
| Shelving | Two adjustable stainless steel shelves |
| Construction | Inner chamber – SUS304 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Equipment |
| Model | OK-HH-408 |
| Price | USD 3,100 (Reference Only) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-HQ-90 |
| Price | USD 2,650 (FOB) |
| Temperature Range | RT+10°C to 200°C |
| Temperature Uniformity | ±2°C |
| Temperature Stability | ±0.5°C |
| Air Exchange Rate | 5–300 cycles/hour (measured at 80°C) |
| Adjustable Air Exchange Interval | 1 min – 99 h |
| Internal Chamber Dimensions | 450 × 450 × 500 mm (W×D×H) |
| External Dimensions | 1100 × 830 × 1600 mm (W×D×H) |
| Power Rating | 4.0 kW |
| Rotating Sample Platform | Ø250 mm, 8–10 rpm |
| Compliance | ASTM D5423-09 (Type II), ASTM D5374-05, UL 1581, IEC 60811, JIS K7212, GB/T 2951, VDE 0472 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-HQ-90 |
| Price | USD 2,650 (FOB) |
| Temperature Range | RT+10°C to 200°C |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Air Exchange Rate | 2–100 cycles/hour |
| Adjustable Air Exchange Interval | 1 min – 99 h |
| Internal Chamber Dimensions (W×D×H) | 450 × 450 × 500 mm |
| External Dimensions (W×D×H) | 1100 × 830 × 1600 mm |
| Power Rating | 4.0 kW |
| Control System | PID-Based Microprocessor Controller with LCD Interface |
| Communication | RS-232/RS-485 |
| Compliance | ASTM D5423-09 (Type II), ASTM D5374-93 (2005), UL 1581, GB/T 2951, IEC 60811, JIS C 3005, VDE 0472 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-NL-50 |
| Load Capacity | 50 kgf (490 N) |
| Force Resolution | 1/100,000 FS (1/250,000 FS for ≤1 kN models) |
| Force Accuracy | ≤0.5% FS (≤0.25% FS for ≤1 kN models) |
| Crosshead Travel | 1000 mm (excl. grips) |
| Test Speed Range | 5–300 mm/min (software-controlled, stepless) |
| Drive System | Panasonic AC servo motor + servo driver |
| Position Feedback | 2500-pulse/rev encoder |
| Load Cell | High-precision explosion-proof strain-gauge transducer with auto-thermal compensation, zero drift <0.03% FS, repeatability ±0.03% FS, overload capacity 150% FS |
| Transmission | Precision ground ball screw + Liming reducer + synchronous belt |
| Guideway | High-precision linear guide rails |
| Data Acquisition | PC-based real-time control & analysis software with curve plotting, peak hold, break-stop, overload protection, unit switching (g/kg/N/kN/lb), report generation & export (PDF/Excel) |
| Compliance Standards | ASTM D412, D3574, D5035, D2061, ISO 37, ISO 34-1, ISO 1798, BS EN ISO 1421, GB/T 16491, GB/T 1040, GB/T 2792, GB/T 3923.1, etc. |
| Dimensions (L×W×H) | 985 × 510 × 1600 mm |
| Power Supply | 220 V, 50/60 Hz |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-NL-50 |
| Capacity | 50 kgf (490 N) |
| Load Cell Accuracy | ≤0.25% FS (for ≤1 kN range) |
| Load Resolution | 1/250,000 full scale |
| Stroke | 1000 mm (excluding grips) |
| Test Speed Range | 5–300 mm/min (software-controlled, stepless adjustment) |
| Drive System | Panasonic AC servo motor + servo driver |
| Transmission | Precision ball screw + timing belt + LM guide rail |
| Force Sensor | Explosion-proof high-precision load cell with auto-thermal compensation, zero drift <0.01% FS/°C, repeatability ±0.03% FS, overload capacity 150% FS |
| Position Resolution | 0.001 mm |
| Data Acquisition | Real-time PC-based control, curve plotting, peak hold, break-stop, overload protection, unit switching (g/kg/N/kN/lbf), report generation & export (CSV/PDF) |
| Compliance Standards | ASTM D412, D3574, D5035, D2061, ISO 37, 1421, 1798, GB/T 16491, GB/T 1040, GB/T 2792, GB/T 3923.1, EN ISO 9163, DIN 53507-A |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-QY-100 |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek color touchscreen HMI |
| Ozone Detection | Non-dispersive UV absorption analyzer (≥5 yr service life) |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
