OKO Instruments
Filter
Showing all 6 results
| Brand | Oko Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,100 (Reference Only |
| Brand | OKO Instruments |
|---|---|
| Model Options | OK-HAST-25 (Ø25×40 cm), OK-HAST-30 (Ø30×50 cm), OK-HAST-40 (Ø40×60 cm), OK-HAST-50 (Ø50×70 cm) |
| Temperature Range | 100–132 °C |
| Humidity Range | 75–100 %RH (saturated steam) |
| Pressure Range | Ambient + 0–4 kg/cm² (≈0–392 kPa gauge) |
| Max. Continuous Operation | 400 hours |
| Chamber Safety Rating | 65 kgf/cm² hydrostatic test at 140 °C |
| Dual-Stage Pressure Safety System | Electronic controller + mechanical pressure relief valve |
| Water Level Monitoring | Integrated capacitive sensor with auto-refill function |
| Steam Generation | Isolated stainless-steel steam generator chamber |
| Door Mechanism | Ergonomic dual-lever locking system |
| Brand | OKO Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OK-TH-408.1 |
| Instrument Type | Benchtop |
| Condensation Method | Air-Cooled |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 20–98 % RH |
| Temperature Uniformity | ≤2 °C |
| Temperature Fluctuation | ±1 °C (high temp), ±2 °C (low temp) |
| Humidity Uniformity | ≤5 % RH |
| Humidity Fluctuation | ±3 % RH |
| Heating Rate | 1.0–3.0 °C/min |
| Internal Chamber Dimensions | 600 × 850 × 800 mm (W × H × D) |
| Brand | OKO Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only – Final Quotation Subject to Technical Configuration and Compliance Requirements) |
| Brand | OKO Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OK-TH-150 |
| Instrument Type | Benchtop |
| Condensation Method | Air-Cooled |
| Temperature Range | 15–45 °C |
| Humidity Range | 30–98 % RH |
| Temperature Deviation | ≤ ±2 °C |
| Temperature Fluctuation | ±1 °C (high-temp), ±2 °C (low-temp) |
| Humidity Deviation | ≤ ±3 % RH |
| Humidity Fluctuation | ±3 % RH |
| Heating Rate | 1.0–3.0 °C/min |
| Internal Chamber Dimensions | 500 × 600 × 500 mm (W × D × H) |
| Brand | OKO Instruments |
|---|---|
| Origin | Imported (Manufactured in Germany with Chinese R&D Integration) |
| Manufacturer Type | Direct Manufacturer & OEM/ODM Provider |
| Cooling Capacity | -70°C to +150°C |
| Humidity Range | 20%–98% RH |
| Temperature Uniformity | ±1.0°C (at 25°C, no load) |
| Humidity Uniformity | ±3.0% RH (at 25°C, 60% RH, no load) |
| Control System | PID-based BTHC (Balanced Temperature & Humidity Control) |
| Refrigerant | R404A (CFC-free) |
| Compressor | Twin-stage hermetic scroll compressor (Tecumseh/Taikang) |
| Noise Level | <60 dB(A) |
| Power Supply | 380 VAC ±10%, 3-phase, 50/60 Hz |
| Water Supply | Auto-filtered tap water system (no deionized water required) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1:2022, IEC 60068-2-2:2022, GJB 1032A–2021, MIL-STD-2164A–2019 |