Ophir
Filter
Showing all 8 results
| Brand | OPHIR |
|---|---|
| Origin | USA |
| Model | HELIOS |
| Power Range | 200 W – 12 kW |
| Energy Range | 200 J – 5 kJ |
| Exposure Time | 0.3 s – 4 s |
| Wavelength Range | 750 nm – 1100 nm |
| Max Beam Diameter | 35 mm |
| Max Energy Density | 4 kJ/cm² |
| Accuracy | ±3% |
| Repeatability | ±1% |
| Response Time | 2.5 s |
| Measurement Interval | 12 s |
| Communication Interfaces | PROFINET, RS232 |
| Operating Temperature | 10–60 °C |
| Operating Humidity | 10–80% RH |
| Shutter Activation | Automatic upon measurement initiation |
| Brand | Ophir |
|---|---|
| Origin | Israel |
| Model | PD10-pJ-C |
| Detector Type | Silicon Photodiode |
| Minimum Measurable Pulse Energy | 10 pJ |
| Maximum Repetition Rate | 20 kHz |
| Spectral Range | 190–1800 nm |
| Output Connector | SMA |
| Damage Threshold | >100 MW/cm² (for 10 ns pulses at 1064 nm) |
| Active Area | 10 mm Ø |
| Rise Time | <1 ns |
| Interface | Compatible with Ophir StarLite, Juno, Vega, and Nova II meters |
| Brand | Ophir |
|---|---|
| Origin | France |
| Sensor Type | Photodiode-based |
| Max Continuous Power | 3 W (with built-in attenuator) |
| Power Range | 10 pW – 3 W |
| Wavelength Range | 190–1100 nm |
| Linearity | ±0.5% (up to 2 mW), ±1% (with attenuator, up to 3 W) |
| Damage Threshold | 10 W/cm² (CW), 0.1 J/cm² (pulsed, 10 ns) |
| Output Signal | Analog voltage (1 V per 1 W typical) |
| Connector | BNC |
| Brand | Ophir |
|---|---|
| Origin | France |
| Type | Pyroelectric Energy Sensor |
| Max. Repetition Rate | 25 kHz |
| Pulse Width Range | 10 ns – 20 ms |
| Energy Range | 10 µJ – 50 J |
| Spectral Range | 0.19–20 µm (with appropriate absorber) |
| Calibration Uncertainty | ±3% (k=2) |
| Rise Time | ~1.5 ms (BF-type) |
| Damage Threshold | 1 J/cm² (1064 nm, 10 ns) |
| Interface | USB or RS-232 (via StarLab or Nova II meter) |
| Brand | Ophir |
|---|---|
| Origin | Israel |
| Model | Pyrocam III / Pyrocam IV |
| Wavelength Range | 13–355 nm & 1.06–3000 µm |
| Detector Type | Thermopile-based 2D array |
| Interface | USB 2.0 or GigE (model-dependent) |
| Active Area | Up to 12.5 × 12.5 mm² |
| Pixel Resolution | 128 × 128 (Pyrocam III), 320 × 320 (Pyrocam IV) |
| Damage Threshold | ≥500 MW/cm² (ns pulses), ≥10 kW/cm² (CW, with optional attenuators) |
| Compliance | CE, RoHS, ISO 17025 traceable calibration available |
| Brand | Ophir |
|---|---|
| Origin | France |
| Model | StarBright |
| Sensor Compatibility | Thermopile, BeamTrack, Pyroelectric (PE-C series), Photodiode |
| Display | 320×240 color TFT LCD |
| Measurement Modes | Digital bar graph, analog needle, real-time line plot (for laser tuning), pulse waveform, Pass/Fail, beam position, stability index, live statistics |
| Sampling Rate | Up to 5 kHz (with pyroelectric sensors) |
| Data Processing | Baseline normalization, density scaling, ratio functions, composite mathematical operations |
| Data Storage | USB flash drive support (unlimited capacity) |
| Interfaces | USB 2.0, RS-232 |
| Software | StarLab PC application, scriptable command files |
| Instrument Drivers | LabVIEW VIs, COM object API |
| Advanced Capabilities | Pulse power measurement (thermopile), exposure energy integration (photodiode) |
| Brand | Ophir |
|---|---|
| Origin | Israel |
| Model | VEGA |
| Probe Compatibility | Thermopile, Pyroelectric, Photodiode, BeamTrack, RP Sensors |
| Display | 320×240 TFT Color LCD |
| Data Storage Capacity | 250,000 readings |
| Sampling Rate (with Pyroelectric Probes) | Up to 4,000 Hz |
| Interface | USB 2.0, RS232, Optional GPIB |
| Software Integration | StarLab, StarCom, LabVIEW, COM Object, ActiveX |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration support |
| Brand | Ophir |
|---|---|
| Origin | Israel |
| Model | SP503U-1550 |
| Detector Type | Phosphor-Converted Silicon CCD |
| Spectral Response Range | 1440–1605 nm (NIR) |
| Output Correction | BeamGage® Linearization Algorithm |
| Compliance | ASTM E1290, ISO 11146-1/-2, USP <857>, FDA 21 CFR Part 11 (Software Audit Trail Enabled) |