| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower (User-Supplied) |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling System | Dual-Stage Cascade Refrigeration with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower |
| Temperature Range | −65°C to +200°C |
| Transition Time (Typical) | ≤15 s between Chambers |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | −65 °C to +180 °C |
| Transition Time (Typical) | ≤15 s between chambers |
| Shock Cycle Count | 1–9999 programmable |
| Dwell Time per Zone | 0.1–999.9 h |
| Data Logging Interval | 3 s to 1 h |
| Storage Capacity | 120 days @ 60 s sampling |
| Compliance | GB/T 2423.1–2008 (Test A), GB/T 2423.2–2008 (Test B), GB/T 10592–2008, GJB 150.3–1986, GJB 360A–1996 Method 107 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Cooling System | Twin-Stage Cascade Refrigeration (German Semi-Hermetic Compressors) |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.3–150.5, GJB 360.7, GJB 367.2, IEC 60068-2-14, SJ/T 10186–10187, QC/T 17, EIA-364-32 |
| Cooling Water Requirement | 10 m³/h External Cooling Tower (User-Supplied) |
| Temperature Range | −65 °C to +150 °C |
| Transition Time (−65 °C ↔ +150 °C) | ≤15 min (typical, per chamber-to-chamber transfer) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Controller Options | TEMI880 Color Touchscreen (EN/CN Switchable) or TEMI300 Membrane Keypad (English Only) |
| Protection Systems | Compressor Overheat/Overcurrent/High-Pressure, Dry-Heater Prevention, Chamber Over-Temperature, Low-Water Detection |
| Standard Features | Dual-Layer Tempered Glass Viewing Window, φ50 mm Left-Side Cable Port, Two Adjustable Sample Racks, Fluorescent Interior Lighting, Four Swivel Casters, Removable Humidification Tank, RS485/RS232 Communication Interface, PC-Based Control Software |
| Temperature Control | Balanced Temperature & Humidity Control (BTSC) System |
| Operating Ambient | +5°C to +35°C |
| Heating | Nickel-Chromium Alloy Wire Heaters |
| Humidification | Surface Evaporation Type |
| Air Circulation | Wide-Band Forced-Air System (Top-Out/Bottom-In), Centrifugal Blower, Multi-Vane Impeller Design |
| Cooling | Air-Cooled, Twin-Stage or Single-Stage Refrigeration Circuit |
| Compressor | Original Tecumseh (France) Hermetic Unit |
| Construction | Outer Shell – SUS304B Stainless Steel |
| Fan Configuration | Axial Flow Circulation Fans (1–2 units depending on chamber volume) |
| Compliance | Designed per IEC 60068-2-14, MIL-STD-810H Method 503.5, and JIS Z 8701-3 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, GB/T 10592–2008, GJB 150.3A–2009 |
| Display | 7″ TFT True-Color LCD Touch Interface |
| Refrigeration System | Dual-Stage Cascade with German Semi-Hermetic Compressors |
| Cooling Tower Requirement | External 10 m³/h Water-Cooled Tower (User-Supplied) |
| Airflow Design | Positive-Pressure Uniform Air Distribution Duct |
| Defrost Method | Intelligent Automatic Defrost Cycle |
| Safety Features | Multi-Level Over-Temperature, Over-Pressure, Phase Failure, and Refrigerant Leak Alarms with Diagnostic Code Display |
| Construction | Stainless Steel Inner Chamber, Insulated Sandwich Panels with Polyurethane Foam (≥150 mm Thickness) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–1989, GJB 150.3–1986 to GJB 150.5–1986, GJB 360.7–1987, GJB 367.2–1987, SJ/T 10186–1991 & SJ/T 10187–1991, IEC 60068-2-14 (Test N: Change of Temperature) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | −70°C to +180°C |
| Thermal Transition Time (5-min dwell) | ≤15 s (−40°C ↔ +125°C) |
| Internal Volume | 100 L |
| Control System | TEMI880 Color Touchscreen Controller (EN/CN Switchable) or TEMI300 Keypad-Based Controller (English Only) |
| Compliance | IEC 60068-2-14, MIL-STD-810H Method 503.7, GB/T 2423.22 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–1989, GJB 150.3–1986, GJB 150.4–1986, GJB 150.5–1986, GJB 360.7–1987, GJB 367.2–1987, SJ/T 10186–1991, SJ/T 10187–1991, IEC 60068-2-14 (Test N: Change of Temperature) |
| Refrigeration Cycle | Dual-stage vapor-compression refrigeration based on reverse Carnot cycle |
| Temperature Range | Typically −65 °C to +150 °C (configurable per model) |
| Transition Time | ≤ 15 s between chambers (typical for two-zone design) |
| Internal Volume | Standard options from 50 L to 500 L |
| Control System | PID-controlled digital temperature controller with programmable ramp/soak profiles |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −55 °C to +150 °C |
| Temperature Stability (Hot/Cold Chambers) | ≤ ±2 °C |
| Sample Zone Temperature Stability (Steady State) | ≤ ±0.5 °C |
| Temperature Uniformity | ≤ ±2.0 °C |
| Sample Load Capacity | 30 kg |
| Temperature Recovery Time | ≤ 5 min |
| Low-Temp Chamber Cooling Time (RT → −55 °C) | ≤ 50 min |
| High-Temp Chamber Heating Time (RT → +150 °C) | ≤ 30 min |
| Transfer Time Between Chambers | ≤ 10 s |
| Interior Material | SUS#304 Stainless Steel |
| Cooling Method | Water-Cooled |
| Compressor | Imported Dual-Stage Cascade Refrigeration Unit |
| Control Interface | Touchscreen Color LCD with PID Auto-Tuning Algorithm |
| Compliance Support | MIL-STD-810G, IEC 60068-2-14, DIN EN 60068-2-14, JIS Z 8702 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System |
| Compressor | Imported Semi-Hermetic German Compressor |
| Cooling Water Requirement | 10 m³/h External Cooling Tower |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GB/T 2423.22-2002, GJB 150.5-2009, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System |
| Compressor | Imported Semi-Hermetic German Compressor |
| Cooling Method | Water-Cooled (Requires External 10 m³/h Cooling Tower) |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2022, ISO 16750-4, QC/T 17-2019 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | -65°C to +150°C |
| Transition Time (Typical) | ≤15 s (between chambers) |
| Compliance | ASTM D648, ISO 11359-2, IEC 60068-2-14, MIL-STD-810H Method 503.5, GB/T 2423.22-2022, GJB 150.5A-2009 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -20 °C to +80 °C |
| Internal Chamber Dimensions | 40 × 40 × 40 cm (D × W × H) |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±2 °C |
| Refrigeration System | R404A refrigerant |
| Compressor | Imported high-efficiency hermetic scroll compressor |
| Cooling Method | Air-cooled condenser |
| Evaporator | Finned-tube coil type |
| Control System | PID auto-tuning with SSR output |
| Display | LED digital temperature & timer display |
| Safety Protections | Compressor overload protection, earth-leakage circuit breaker |
| Chamber Material | 304 stainless steel interior |
| Optional Features | Dual-sensor temperature control, high-temp active cooling, RS-485/USB communication interface |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | -70°C to +180°C (typical standard configuration) |
| Thermal Transition Time | ≤15 s (between chambers, typical) |
| Control System | TEMI880 Color Touchscreen (EN/CN Switchable) or TEMI300 Membrane Keypad Controller (English Only) |
| Refrigeration | Twin-Stage or Single-Stage Hermetic Compressor (Original Tecumseh or Danfoss) |
| Internal Volume | Standard 100 L / 200 L / 400 L Options |
| Compliance | Meets ASTM D5229, ISO 16750-4, MIL-STD-810H Method 503.5, IEC 60068-2-14 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.3–150.5, IEC 60068-2-14, SJ/T 10186–10187, QC/T 17, EIA-364-32 |
| Refrigeration Cycle | Dual-stage vapor-compression reverse Carnot cycle with independent high-temp/low-temp circuits |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Display | 7″ TFT True-Color LCD Touchscreen Controller |
| Door Viewport | Multi-Layer Tempered Glass with Conductive Film Defrosting & Internal LED Illumination |
| Air Circulation | Low-Noise High-Efficiency AC Motor with Multi-Blade Centrifugal Impeller |
| Mobility | Lockable PU Casters |
| Test Port | One Φ50 mm Access Port (Left Side, Sealed Gland) |
| Safety Systems | Over-Temperature Protection, Compressor Overload/High-Pressure Cutout, Leakage Current Detection, Water Shortage Alarm, Real-Time Fault Logging & Auto Shutdown |
| Refrigeration Architecture | Modular Hermetic Compressor Units |
| Evaporator Integrity | Water-Immersion Leak Testing Certified |
| Airflow Design | Positive-Pressure Uniformity Optimized Duct System |
| Defrost Method | Adaptive Scheduled Defrost with Reduced Cycle Duration |
| Control Algorithm | Proprietary Fuzzy Logic Thermal Load Compensation Engine |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70°C to +200°C |
| Preheat Upper Limit | +200°C |
| Precool Lower Limit | −70°C |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C (Steady State), ≤ ±2°C (Cycling) |
| Ramp Rate (RT → +200°C) | ~40 min |
| Ramp Rate (RT → −70°C) | ~60 min |
| Transfer Time Between Chambers | ≤ 5 s |
| Chamber Configurations | Dual-Chamber or Triple-Chamber |
| Control Interface | Touchscreen Color LCD with PID Auto-Tuning |
| Cycle Programmability | Start Mode Selection (Hot/Cold First), Cycle Count Setting, Auto-Defrost, Scheduled Start |
| Compliance Support | Designed for ASTM D5229, ISO 11359-2, IEC 60068-2-14, MIL-STD-810H Method 503.7 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +150 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 30–98% RH |
| Humidity Deviation | +2 / −3% RH |
| Avg. Ramp Rate | 0.7–1.0 °C/min |
| Time Setting Range | 0–9999 h |
| Power Supply | AC 380 V |
| Internal Dimensions (W×D×H, mm) | 400×500×400 (OK-TS-100) to 1000×1000×1000 (OK-TS-1000) |
| External Dimensions (W×D×H, mm) | 1200×1650×1100 (OK-TS-100) to 1900×2100×1850 (OK-TS-1000) |
| Observation Window | Ø50 mm test port & illuminated tempered glass viewport |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | RT to −70 °C |
| Test Zone Range | +60 °C to +150 °C (Hot Shock), 0 °C to −65 °C (Cold Shock) |
| Switching Mechanism | Pneumatic Air-Damper–Actuated Static Specimen Method |
| Recovery Time | <5 min |
| Temperature Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration | Dual-Stage Cascade System with R404A/R23 Refrigerants |
| Construction | Interior – Mirror-Finish SUS304 Stainless Steel |
| Insulation | High-Density Fire-Retardant PU Foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +150 °C (selectable) |
| Internal Chamber Dimensions | 400 × 500 × 500 mm (OK-TS-100) / 500 × 650 × 700 mm (OK-TS-250) |
| External Dimensions | 1030 × 1020 × 1470 mm / 1100 × 1170 × 1700 mm |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Heating Rate | ≥ 2–3 °C/min |
| Cooling Rate | ≤ 1 °C/min |
| Refrigeration System | Twin-stage cascade refrigeration with hermetic French Tecumseh compressors |
| Insulation | High-density ultra-fine glass fiber |
| Heating Element | Nickel-chromium alloy sheathed heaters |
| Evaporator | Finned multi-section evaporator |
| Air Circulation | Single-loop, extended-shaft low-noise stainless steel centrifugal blower |
| Door Seal | High-performance silicone rubber gasket rated for −70 °C to +150 °C |
| Control System | Imported precision digital PID controller with solid-state relays and industrial-grade I/O modules |
| Safety Protections | Over-temperature, compressor high-pressure, phase failure, motor overload, door interlock, and refrigerant leak detection |
| Brand | Other brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General distributor |
| Price | USD 13,800 (approx. based on ¥100,000 at 7.25 exchange rate) |
| Internal Dimensions (W×H×D) | 400×450×400 mm to 1000×1000×1000 mm |
| Construction | SUS304 stainless steel inner chamber, A3 steel outer shell with powder coating |
| Viewing Window | Reinforced heated tempered glass with LED lighting |
| Test Port | Ø50 mm on left side |
| Controller | Touchscreen PID temperature controller with parameter lock and auto-tuning |
| Refrigeration | Dual-stage or single-stage cascade system with Tecumseh (France) compressors, Acro (USA) dry filters, Guanya (Taiwan) oil separators, Castel (Italy) solenoid valves |
| Air Circulation | Multi-wing centrifugal blower with optimized inlet/outlet duct design for uniform thermal distribution and rapid recovery (<5 min after door opening) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +150 °C |
| Thermal Shock Conditions | −40 °C ↔ +70 °C and −55 °C ↔ +85 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Stability | ≤ ±0.5 °C |
| Transfer Time (Cold ↔ Hot) | ≤ 5 s |
| Temperature Recovery Time | ≤ 5 min |
| Control Resolution | 0.1 °C / 1 s |
| Programmable Capacity | 10 programs × 99 segments |
| Compliance | GB/T 2423.22–1989, GJB 150.5A–2009, MIL-STD-810G Method 503.5 |