OUKE
Filter
Showing all 5 results
| Brand | Ouke |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported Components |
| Price | USD 2,650 (FOB Guangdong) |
| Internal Dimensions (W×H×D, mm) | 500×600×500 to 1000×1000×1000 |
| External Dimensions (W×H×D, mm) | 1750×2250×2350 to 2350×2800×3000 |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range (Optional) | 20–98% RH |
| Rapid Thermal Transition Range | −45 °C to +85 °C |
| Rapid Thermal Transition Accuracy | ±3.0 °C |
| Ramp Rates | 5–30 °C/min (Linear or Nonlinear Mode, Selectable) |
| Temperature Resolution | 0.1 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0% RH |
| Temperature Control Stability | ±0.5 °C |
| Humidity Control Stability | ±2.5% RH |
| Inner Chamber Material | SUS304 Stainless Steel |
| Outer Chamber Material | Cold-Rolled Steel with Powder Coating or Stainless Steel |
| Insulation | High-Density Polyurethane Foam (CFC-Free) |
| Refrigeration System | Water-Cooled |
| Compressor | Tecumseh (France) or Bitzer (Germany) |
| Power Supply | AC 380 V, 3-Phase 5-Wire, 50/60 Hz |
| Weight | 950–2300 kg |
| Brand | OUKE |
|---|---|
| Model Series | OK-ES |
| Frequency Range | 0.5–600 Hz (±0.1%) |
| Max. Load Capacity | 80 kg (100 kg peak) |
| Peak Acceleration | 0–15 g (0–150 m/s²) |
| Peak Sine Force | 1500 kgf |
| Displacement (p-p) | 0–4 mm |
| 台面尺寸 | 500 × 500 × 6 mm (standard) |
| 台体 Dimensions (H×W×D) | 500 × 550 × 500 mm |
| Power Input | 20 A, 200–240 VAC ±20%, 50/60 Hz |
| Power Consumption | 4.4 kW |
| Cooling Method | Natural Air Cooling |
| Operating Ambient | −10 °C to +80 °C, 10–95% RH |
| Noise Level | ≤50 dB(A) |
| Magnetic Field Emission | ≤100 mG at 1 m |
| Control Interface | RS-485 (PC-compatible) |
| Resolution | Frequency display to 0.01 Hz |
| Compliance | Supports ASTM D999, ISO 2247, IEC 60068-2-6, MIL-STD-810H, GB/T 4857.7, GB/T 2423.10 |
| Brand | Ouke |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 105–132 °C (control point) |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 100 % RH |
| Humidity Stability | ±2.5 % RH |
| Humidity Uniformity | ±5.0 % RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2 kg/cm², control point) |
| Heating Time | 35 min (ambient to 132 °C) |
| Pressurization Time | 40 min (ambient to 2 kg/cm²) |
| Capacity | Standard chamber configuration for automotive subassemblies and electronic packages |
| Safety Features | Dual interlocked circular door, automatic pressure relief, vacuum pre-conditioning, real-time LED timer with start-trigger logic, fault-indicating safety LIMIT system |
| Compliance | Designed per IEC 60068-2-66, JESD22-A102D, MIL-STD-202G Method 108, and aligned with JEDEC A110B for HAST/PCT testing protocols |
| Brand | Ouke |
|---|---|
| Model Series | KS-TH-100 / KS-TH-225 / KS-TH-500 / KS-TH-800 / KS-TH-010 |
| Internal Dimensions (D×W×H, mm) | 450×450×500 |
| External Dimensions (D×W×H, mm) | 1100×750×1000 |
| Construction | Exterior – Cold-rolled carbon steel with phosphating + electrostatic powder coating OR SUS304 stainless steel brushed finish |
| Temperature Range | +10°C to +150°C |
| Humidity Range | 85–98% RH |
| Temp. Uniformity/Fluctuation | ±2°C / ±0.5°C |
| Humidity Deviation | +2 / −3% RH |
| Heating Rate | 1–3°C/min |
| Controller | Microprocessor-based integrated temperature & humidity controller |
| Set/Display Resolution | 0.1°C / 1% RH |
| Sensor | PT100 platinum resistance thermometer & capacitive RH sensor |
| Heating System | Independent nickel-chromium alloy heater |
| Humidification | External isolated stainless steel shallow-surface evaporative humidifier |
| Dehumidification | Evaporator coil dew-point contact method |
| Water Supply | Auto-controlled with condensate recovery |
| Air Circulation | High-efficiency low-noise AC motor + multi-blade centrifugal impeller |
| Safety Protections | Over-temperature, over-current, leakage, short-circuit, dry-run, motor overheat, water shortage |
| Power Supply | AC 380V ±10%, 50 ±0.5 Hz, 3-phase 5-wire |
| Ambient Operating Conditions | 5–30°C, ≤85% RH |
| Energy-Saving Technology | PWM-controlled refrigerant flow regulation (cold/hot bypass + main circuit) enabling compressor-only low-temp stabilization — ~40% energy reduction vs. conventional PID-heating compensation methods |
| Compliance Context | Designed for test execution per IEC 60068-2-1 (Cold), IEC 60068-2-2 (Dry Heat), IEC 60068-2-30 (Damp Heat, Cycling), MIL-STD-810H Method 502.6 & 507.6, and supports GLP/GMP-aligned validation protocols including IQ/OQ documentation traceability |