Oxford Instruments
Filter
Showing 31–60 of 108 results
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecLive |
| Detector Active Area | Up to 170 mm² |
| Maximum Quantitative Count Rate | 400 kcps |
| Maximum Mapping Count Rate | 1,000 kcps |
| Detector Type | Silicon Drift Detector (SDD) with Extreme Electronics Architecture |
| Compliance | Designed for integration with field-emission and tungsten SEM platforms per IEC 61000-4 EMC standards |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecPharma |
| Compliance | FDA 21 CFR Part 11, EU Annex 11, GxP-aligned |
| Software Platform | AZtecLive-based |
| User Authentication | Integrated Windows Active Directory / LDAP |
| Audit Trail | Immutable, timestamped, user-attributed, inspector-accessible |
| Digital Signature | Enforced per action (acquisition, processing, reporting) |
| SOP Integration | Configurable acquisition profiles with version-controlled parameters |
| Real-time EDS Imaging | Elemental mapping with live spectral overlay comparison |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecTEM |
| Instrument Type | EDS Software Platform |
| Compatibility | JEOL 200 kV & 300 kV Transmission Electron Microscopes equipped with JED EDS detectors |
| Key Features | Point-and-ID analysis, LineScan, Elemental Mapping (TruMap, QuantMap), Drift Correction (AutoLock), Real-time Dynamic Imaging (AZtecLive) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecWave |
| Detector Type | Wavelength Dispersive Spectrometer (WDS) with Integrated EDS Compatibility (Ultim Max) |
| Roland Circle Radius | 210 mm |
| Energy Resolution | <10 eV (Mn Kα, typical) |
| Detection Limit | <100 ppm (matrix-dependent) |
| Peak-to-Background Ratio | >10,000:1 (typical for major elements) |
| Optical Geometry | Focusing Johann-type spectrometer with bent crystals |
| Incident Slit | Motorized, variable width |
| Installation | Tilt-mounted for minimal working distance dependency |
| Software Platform | AZtecWave v4.x or later |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Model | C-Blue One |
| Image Resolution | 0.5 MP (812 × 612), 1.7 MP (1608 × 1104), or 7.1 MP (3208 × 2200) |
| Pixel Size | 9 µm (0.5 MP & 1.7 MP variants), 4.5 µm (7.1 MP variant) |
| Sensor Diagonal | 9.6 mm (0.5 MP), 17.6 mm (1.7 MP & 7.1 MP) |
| Interface | CoaXPress 2.0 or SFP+ 10 GigE |
| Bit Depth | 14-bit |
| Quantum Efficiency | >70% @ peak (550–650 nm) |
| Read Noise | <1.5 e⁻ (typical, correlated double sampling) |
| Shutter Type | Global shutter |
| Compliance | GigE Vision v2.0, GenICam3 |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Model | C-Blue One UV |
| Image Resolution | 2848 × 2848 |
| Pixel Size | 2.74 µm |
| Sensor Diagonal | 11.2 mm |
| Interface | CoaXPress 2.0 or SFP+ 10GigE |
| Bit Depth | 14-bit |
| Quantum Efficiency | >70% (peak in UV) |
| Shutter Type | Global Shutter |
| Spectral Range | 200–1000 nm |
| Cooling | Active thermoelectric stabilization down to 0 °C |
| Lens Mount | CS-mount (with C-mount adapter) |
| ADC Modes | 8-bit / 12-bit selectable |
| Analog Gain | up to 24 dB |
| Digital Gain | up to 48 dB |
| ROI & Multi-Window Support | Yes |
| Compliance | GigE Vision v2.0, GenICam v3.x |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | C-Nano |
| CCD Camera Resolution | 1244 × 1024 pixels |
| Maximum Pattern Acquisition Rate | 870 Hz |
| Spatial Resolution | 2 nm |
| Angular Resolution | < 0.05° |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Model | C-RED 2 ER |
| Effective Pixels | 640 × 512 |
| Pixel Size | 15 µm |
| Frame Rate | 600 fps (full frame), up to 32,066 fps (region-of-interest) |
| Spectral Range | 1.1–1.9 µm (C-RED 2 ER 1.9) or 1.2–2.2 µm (C-RED 2 ER 2.2) |
| Read Noise | < 50 e⁻ (1.9 µm version), < 40 e⁻ (2.2 µm version) |
| Cooling | Integrated dual-stage thermoelectric cooler (ΔT ≤ 60 °C vs. ambient) |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Model | C-RED 2 Lite |
| Effective Resolution | 640 × 512 |
| Pixel Size | 15 µm |
| Detector Type | InGaAs PIN photodiode array |
| Electronic Shutter Pulse Width | < 5 µs |
| Cooling | Passive thermoelectric stabilization (fanless) + optional water-cooled cold plate |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Model | C-RED 2 |
| Effective Resolution | 640 × 512 pixels |
| Pixel Size | 15 µm |
| Frame Rate | up to 600 fps |
| Read Noise | <30 e⁻ |
| Electronic Shutter Pulse Width | <5 µs |
| Maximum Exposure Time | 60 s |
| Dynamic Range | 93 dB |
| ADC Resolution | True 16-bit |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Model | C-RED 3 |
| Resolution | 640 × 512 pixels |
| Pixel Size | 15 µm |
| Readout Speed | Up to 600 fps (full frame) |
| Integration Time | < 5 µs (electronic shutter) |
| Cooling | Uncooled |
| Form Factor | Compact OEM-ready design |
| Power Consumption | < 5 W |
| Interface | Camera Link HS or 10 GbE |
| Spectral Range | 0.9–1.7 µm |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C-RED New Space |
| Effective Pixels | 640 × 512 |
| Pixel Size | 15 µm |
| Full-Frame Frame Rate | 600 fps |
| Windowed Mode (32 × 4) | 32,066 fps |
| Read Noise | <30 e⁻ |
| Dynamic Range | 93 dB (True 16-bit mode) |
| Operating Temperature Range | -40 °C to +65 °C |
| Sensor Material | InGaAs (VGA array) |
| Cooling | Advanced passive/thermoelectric hybrid thermal management |
| Brand | Oxford Instruments |
|---|---|
| Origin | France |
| Model | C-RED One |
| Sensor Format | 320 × 256 |
| Pixel Size | 24 µm |
| Spectral Range | J/H/K bands (0.9–2.5 µm) |
| Readout Noise | Sub-electron |
| Max Frame Rate | 3500 fps (full frame) / 10 kHz (ROI) |
| Cooling | Integrated pulse-tube cryocooler to 90 K |
| Vacuum System | Sealed, autonomous regeneration |
| Vibration Reduction | 10× active suppression |
| Readout Modes | Global reset, rolling reset, single readout, CDS, multiple non-destructive reads (MDR) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | C-Swift |
| CCD Camera Resolution | 1244 × 1024 |
| Maximum Frame Rate | 870 Hz |
| Spatial Resolution | 2 nm |
| Angular Resolution | < 0.05° |
| Brand | Oxford Instruments |
|---|---|
| Origin | USA |
| Model | CMI233 |
| Measurement Principle | Dual-mode (Magnetic Induction for ferrous substrates |
| Measurement Range | 0–3.05 mm (magnetic induction), 0–1.52 mm (eddy current) |
| Resolution | 0.1 µm |
| Accuracy | ±1% or ±0.1 µm (per certified reference standards) |
| Minimum Substrate Thickness | 0.35 mm |
| Minimum Curvature Radius | 5 mm (convex), 25 mm (concave) |
| Minimum Test Area | Ø20 mm |
| Compliance | ASTM B499, B530, B244, B259 |
| Data Storage | 12,400 readings |
| Display | 1/2-inch backlit LCD |
| Interface | RS-232 serial port |
| Power | 9 V alkaline or rechargeable battery |
| Weight | 260 g (incl. battery) |
| Dimensions | 149 × 79.4 × 30.2 mm |
| Units | Switchable metric/imperial |
| Statistical Functions | Mean, SD, min/max, histogram, CPK, count |
| Scan Mode | Time-based averaging with min/max capture |
| Keypad | Sealed membrane (9-key basic / 16-key enhanced) |
| Brand | Oxford Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cypher ES Polymer Edition |
| Price Range | USD 420,000 – 700,000 (est.) |
| Instrument Type | Atomic Force Microscope (AFM) |
| Application Class | Materials Science |
| Position Detection Noise | 625 Hz |
| Sample Dimensions | Ø < 15 mm, Thickness < 5 mm |
| Stage Travel Range | 180 mm × 180 mm |
| Environmental Control | Sealed fluid/gas chamber compatible |
| Temperature Control Range | 0–250 °C |
| Nanomechanical Capabilities | Integrated NanoMechPro toolkit (Force Modulation, Contact Resonance, and HarmoniX™) |
| Excitation Method | blueDrive photothermal excitation for tapping mode |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Cypher VRS1250 |
| Instrument Type | Materials-Focused Atomic Force Microscope |
| Position Detection Noise | X&Y < 60 pm |
| Sample Dimensions | Ø ≤ 15 mm, Thickness ≤ 7 mm |
| Stage Travel Range | 180 mm × 180 mm |
| Software | SmartScan |
| Environmental Compatibility | Fully compatible with Cypher ES environmental control system (temperature-controlled sample stage: –30 °C to +250 °C) |
| Excitation Method | blueDrive™ photothermal excitation |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Etch |
| Pricing | Upon Request |
| Brand | Oxford Instruments |
|---|---|
| Origin | Switzerland |
| Model | FT-I04 |
| Instrument Type | Nanoindenter |
| Maximum Load Range | 2 N (across 5 selectable load channels) |
| Load Resolution | 0.5 nN (FT-S200 sensor) |
| Displacement Resolution | 0.05 pm |
| Indenter Tip Materials | Diamond, Tungsten Carbide, Sapphire |
| Indenter Geometries | Berkovich, Cube Corner, Flat Punch, Wedge, Conical, Spherical |
| Brand | Oxford Instruments |
|---|---|
| Origin | Switzerland |
| Model | FT-NMT04 |
| Load Range | 5 selectable full-scale channels, up to 2 N (FT-S2’000’000) |
| Load Resolution | 0.5 nN (FT-S200) |
| Displacement Range | 0.05 nm – 21 mm |
| Displacement Resolution | 0.05 pm |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | GeoSpec |
| Frequency Options | 2 MHz, 12 MHz, 20 MHz (up to 23 MHz) |
| Sample Type | Solid rock cores |
| Field Strength | Low-field NMR |
| Core Diameter Compatibility | 1 in to 6 in (25.4 mm to 152.4 mm) |
| Software Platform | LithoMetrix (base), GIT Suite (optional upgrade) |
| Gradient Capability | Pulsed Field Gradient (PFG) enabled |
| Operating Environment | Compatible with P5 high-pressure/high-temperature (HPHT) probe unit |
| Detection Technology | Q-Sense RF detection for short echo times (TE) |
| Application Scope | Rock physics characterization, porosity quantification, fluid typing, T₂ distribution analysis, capillary pressure modeling, diffusion-weighted imaging |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WDS |
| Price | USD 185,000 (FOB UK) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Ionfab 300 |
| Configuration Options | Direct-Load, Single-Wafer Transfer, Cassette-to-Cassette Transfer |
| Process Modes | Ion Beam Deposition (IBD), Ion Beam Etching (IBE), Co-deposition & Reactive IBE |
| Wafer Handling | 300 mm single-wafer or cluster-integrated |
| Surface Roughness | Sub-nanometer RMS (typical for IBD films) |
| Uniformity | ≤±1.5% across 300 mm wafer (process-dependent) |
| Reproducibility | CV < 2% for etch/deposition rate (run-to-run) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | iXon Ultra 897 |
| Pixel Size | 16 µm |
| Readout Speed | 17 MHz (full frame) |
| Frame Rate | 56 fps (512 × 512), 595 fps (128 × 128 ROI) |
| Cooling | Thermoelectric to −100 °C |
| Quantum Efficiency | Extended back-illuminated response (EX2 technology) |
| Gain Calibration | RealGain™ and EMCAL™ |
| Interface | USB 2.0 with raw data access |
| Operating Modes | EMCCD and conventional CCD |
| Software Features | OptAcquire, iCam, Counting Conversion, Edge Suppression |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Jupiter Discovery AFM |
| Pricing | Available Upon Request |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Matrix |
| Price Range | USD 320,000 – 385,000 |
| Instrument Type | Magnetic Force Microscope (MFM) Control System |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Microstat |
| Temperature Range | 1.5 K to 300 K (depending on configuration) |
| Cooling Method | Closed-cycle helium cryocooler or liquid helium flow cryostat |
| Optical Access | Dual windows (UV to FIR transmission, optional AR coatings) |
| Electrical Feedthroughs | Up to 24 low-noise coaxial or twisted-pair leads |
| Footprint | Compact benchtop design (< 300 mm × 300 mm base) |
| Vibration Isolation | Active/passive hybrid stage stabilization |
| Compliance | CE, UKCA, RoHS |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | MicrostatHiRes |
| Temperature Range | 2.7 K – 500 K (with optional rotary pump) / 3.4 K – 500 K (standard) |
| Base Temperature Stability | ±0.1 K |
| Helium Consumption at 4.2 K | < 0.70 L/hr (with low-loss transfer line) |
| Cool-down Time from RT to 4.2 K | ~15 min (with pre-cooled transfer line) |
| Working Distance | 2.2 mm |
| Sample Vibration | < 20 nm (measured in SEM environment) |
| Mass | 1.5 kg |
| Controller | Mercury iTC |
| Communication Interfaces | RS232, USB (serial emulation), TCP/IP, GPIB |
| Software Integration | LabVIEW driver library and virtual instrument support |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | MQC-R |
| Magnet Frequency | 23 MHz |
| Probe Diameter Range | 10–26 mm |
| Sample Volume Capacity | Up to 14 mL |
| Temperature Control Range (Liquid) | –5 °C to +70 °C |
| Pulsed Field Gradient (PFG) Strength | >3.0 T/m |
| Nuclei Support | ¹H, ¹⁹F, and other quadrupolar/non-quadrupolar nuclei via configurable probes |
| Configurability | Modular hardware and software options for TD-NMR experiments including 1D/2D relaxation, diffusion, and distribution analysis |