Parr
Filter
Showing 1–30 of 33 results
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | Parr Modular Reaction System (MRS) with 16-Station High-Throughput Configuration |
| Reactor Type | Benchtop Batch/Parallel Autoclave Reactor |
| Heating Method | Electric Cartridge Heaters with Aluminum Block Thermal Management |
| Control Architecture | Dual 4871 Process Controllers with 16 × 4875 Power Modules |
| Pressure Rating | Up to 2000 psi (13.8 MPa) |
| Temperature Range | Ambient to 350 °C |
| Vessel Capacity | Standard 4560 Microreactors (25–100 mL) |
| Stirring | Magnetic or Mechanical Drive Options |
| Safety Features | Rupture Discs, Pressure Relief Valves, Interlocked Access Doors |
| Compliance | Designed per ASME BPVC Section VIII Div. 1, CE Marked for EU Lab Use |
| Software Interface | Parr PC-Based Control Suite (Supports ASTM E2500-19, FDA 21 CFR Part 11 Audit Trail & Electronic Signature Ready) |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 3900 Series |
| Operating Pressure | Up to 5 atm |
| Max. Temperature | 80 °C |
| Drive Mechanism | Motorized Oscillating Motion |
| Heating Method | External Electric Heating Jacket |
| Temperature Control | PID Controller with Internal Thermocouple Feedback |
| Safety Certification | Explosion-Proof Options Available |
| Compliance | Designed for GLP-compliant hydrogenation research in pharmaceutical development |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4500 Series |
| Vessel Capacity | 0.075–2 L |
| Construction Material | 316 Stainless Steel |
| Maximum Operating Pressure | 3000–5000 psi (207–345 bar) |
| Vacuum Capability | Yes (rated for full vacuum to full positive pressure) |
| Drive Type | Magnetic Coupling or Gear-Driven Stirring |
| Temperature Range | Up to 540 °C |
| Certifications | ASME Section VIII Div. 1, UL/cUL, CSA, CE, ISO 9001 |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | 4520 |
| Volume Range | 1000 mL – 2000 mL |
| Maximum Operating Pressure | 130 atm (13.2 MPa) |
| Maximum Operating Temperature | 350 °C |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Vacuum Capability | Not Designed for Vacuum Service |
| Regulatory Compliance | Compliant with ASTM G187 (High-Pressure Reaction Vessel Safety), FDA-relevant design principles for pharmaceutical process development |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4530 Series |
| Vessel Capacity | 1000 mL / 2000 mL |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 130 atm (13.2 MPa) |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4540 Series |
| Vessel Capacity | 600 mL / 1200 mL |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 345 atm (5000 psi) |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Configuration | Benchtop & Floor-Standing Options |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4550 Series |
| Volume Options | 3.75 L (1 gal) and 7.5 L (2 gal) |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 130 atm |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, uV, ISO 9001 |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | 4555 Series |
| Price Range | USD $130,000–$260,000 (FOB) |
| Usable Volume | 10 L to 18.75 L |
| Maximum Operating Pressure | 130 atm (13.2 MPa) |
| Maximum Operating Temperature | 350 °C |
| Construction Materials | 316 Stainless Steel, Hastelloy C-276, Hastelloy C-2000 |
| Vacuum Capability | Not rated for vacuum service |
| Certification | ASME Section VIII Div. 1, UL/cUL Listed (uV), ISO 9001:2015, CSA C22.2 No. 61010-1, CE Marked |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4560 Pressure Stirred Autoclave |
| Volume Range | 100–600 mL (Models 4561–4568) |
| Max Operating Pressure | 200 bar |
| Max Operating Temperature | 225–350 °C |
| Configuration | Benchtop Miniature Autoclave System |
| Certification | ASME BPVC Section VIII Div. 1 Compliant Vessels |
| Drive Type | Magnetically Coupled or Mechanical Seal Stirring Assembly |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4590 Series |
| Working Pressure | Up to 575 bar |
| Maximum Temperature | Up to 600 °C |
| Vessel Volume Options | 25 mL – 18.75 L |
| Construction Materials | ASTM-certified alloys (e.g., 316 SS, Hastelloy C-276, Inconel 600, Titanium Grade 2, Zirconium), borosilicate glass, or PTFE-lined configurations |
| Stirring Options | Magnetic drive (0–1800 rpm), gear-driven, pneumatic, or explosion-proof motorized agitators |
| Heating Methods | Electric heating mantle, aluminum block heater, steam/oil jacket |
| Closure Types | Clamp-style (open-loop) or threaded (screw-cap) head design |
| Certifications | ASME Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 4632 |
| Price Range | USD 68,000 – 109,000 (estimated) |
| Maximum Operating Pressure | 10,000 psi (68.9 MPa) |
| Maximum Temperature | 200 °C |
| Extraction Vessel Volume | 2 L |
| Siphon Cup Volume | 450 mL |
| Solvent Flow Cycles | 15–22 cycles/hour |
| Total Extraction Duration | Up to 6 h |
| Compliance | ASTM D2307, ASTM D3455, IEC 60851-5, UL 1446 |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | Parr 4871 |
| Configuration | Fully Automated Continuous Flow Tubular Reactor System |
| Core Components | Integrated Gas/Liquid Feed System, Jacketed Tubular Reactor with Preheater & Circulating Water Bath, Product Collection & Back-Pressure Regulation, Automated Sampling Unit, PARR 4871 Process Control System |
| Compliance Framework | Designed to support GLP-compliant process development and ASTM D6866 / ISO 13877-aligned biofuel characterization workflows |
| Regulatory Readiness | Supports 21 CFR Part 11–compliant audit trails via optional software validation package |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Parr 4871 |
| Pricing | Available Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 4871 High-Pressure, Precision-Temperature-Controlled Corrosion Research System |
| Pricing | Upon Request |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4878 |
| Operating Pressure | 5000 psi |
| Operating Temperature | 500 °C |
| Sample Capacity | 6 vials |
| Dimensions | 35 × 40 × 110 cm |
| Compliance | Compatible with all standard Parr autoclaves and pressure vessels |
| Purge Function | Integrated automated inert-gas purge cycle |
| Control Interface | Touchscreen HMI with graphical workflow display |
| Connectivity | iOS/Android remote monitoring support |
| Footprint | 33 × 33 cm |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 5100 |
| Capacity Range | 300 mL – 1800 mL |
| Vessel Material | Borosilicate Glass (Class A) |
| Maximum Operating Pressure | 10 atm (glass vessel) / 65 atm (stainless steel variant) |
| Maximum Temperature | 200 °C |
| Stirring Speed | Up to 1800 rpm |
| Sealing System | O-ring–based open-loop closure with high-temp elastomer (FKM/Viton®) |
| Jacket Type | Optional glass-jacketed, stainless steel, or removable electric heating mantle |
| Vacuum Capability | Not rated for vacuum service |
| Compliance | Designed per ASTM E2479 and ISO 17025–aligned laboratory practice guidelines |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 5400 |
| Type | Continuous Tubular High-Temperature High-Pressure Reactor System |
| Maximum Temperature | 300–600 °C (customizable) |
| Maximum Pressure | 200–350 bar (customizable) |
| Tube Diameter | 1/2″ to 4″ |
| Tube Length | 12″ to 70″ |
| Construction Materials | Stainless Steel, Alloy 400, Hastelloy C-276, Hastelloy B3, Titanium Grades 2/4/7, Monel 400, Nickel 200 |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 6200 |
| Measurement Mode | Isoperibol |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | 6–7 min |
| Heat Capacity | 33,000 J |
| Outer Water Jacket Volume | 2 L |
| Inner Water Bucket Volume | 342 mL |
| Oxygen Bomb Pressure Rating | 200 atm |
| Bomb Volume | 342 mL |
| Data Storage Capacity | 1000 tests |
| Interface Options | RS-232, USB, Ethernet, Balance Integration, Printer Port |
| Operating System | Linux-based embedded controller |
| Calibration & Reporting | Automatic correction for fuse wire, nitric acid formation, sulfur oxidation, and hydrogen combustion enthalpy |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | 6400 |
| Price | Upon Request |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 6400 |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | 6–7 min |
| Heat Capacity | 33,000 J/K |
| Outer Water Jacket Volume | 2 L |
| Inner Water Bucket Volume | 342 mL |
| Oxygen Filling | Fully Automated |
| Jacket Water Filling | Fully Automated |
| Pressure Release | Automated |
| Bomb Rinsing | Automated |
| Data Storage Capacity | 1,000 tests |
| Connectivity | Ethernet |
| Display | Touchscreen LCD |
| Measurement Principle | Isoperibol (Constant-Temperature Jacket) |
| Brand | PARR |
|---|---|
| Model | Parr Acid Digestion Bomb |
| Construction | Stainless Steel Body with PTFE (Teflon) Liner |
| Max Operating Temperature | 250 °C |
| Max Operating Pressure | 1800–5000 psig |
| Sample Volume Capacity | 23–125 mL |
| Application | Closed-Vessel Acid Digestion for Trace Element Analysis |
| Compliance | Designed for ASTM D5174, EPA Method 3050B/3051A/3052, ISO 11466, and USP <231> sample preparation workflows |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Parr ASTM G146 |
| Pricing | Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | G-T-O |
| Pricing | Upon Request |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | Parr HT/HP Electrochemical Corrosion Test System |
| Pricing | Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Microwave Digestion Vessel |
| Pricing | Upon Request |
| Max Operating Temperature | 250 °C |
| Max Operating Pressure | 1200 psig |
| Sample Volume Capacity | 23–45 mL |
| Construction | Reinforced High-Performance Polymer Outer Sleeve with PTFE Liner |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Instrument Type | Imported Laboratory System |
| Model | 2901 Ignition Propellant Combustion & Ultra-Fast Pressure Release Curve Analyzer |
| Pricing | Available Upon Request |
| Brand | PARR |
|---|---|
| Origin | Imported |
| Manufacturer Status | Authorized Distributor |
| Model | Sample Combustion Bomb System |
| Pricing | Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | VLE-2000 Vapor-Liquid Equilibrium (VLE) Vapor Pressure Measurement System |
| Pricing | Available Upon Request |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model Series | 5000-Series Parallel Reactor System |
| Vessel Volume Range | 0.27–0.45 L (270–450 mL) |
| Construction Material | 316 Stainless Steel (T316SS), Hastelloy C-273/C-2000/B2/B3, Monel, Zirconium Alloys |
| Operating Pressure | Up to 5000 psi (345 bar) |
| Operating Temperature | Up to 350 °C |
| Stirring Speed | 0–600 rpm |
| Vacuum Capability | Down to 3000 psi (negative pressure not applicable |
| Control System | Honeywell 4870 Multi-Parameter Process Controller with PID and ramp/soak programming |
| Software Interface | Windows-based PC control with real-time data acquisition, historical database logging, and graphical analysis |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4600 / 4700 Series |
| Vessel Volume Range | 22 mL – 20 L |
| Maximum Operating Temperature | 250°C – 500°C |
| Maximum Operating Pressure | 115 bar (1700 psi) – 345 bar (5000 psi) |
| Construction Materials | Stainless Steel (316, 304), Alloy 400, Hastelloy C-276/B3, Titanium Grades 2/4/7, Monel 400, Nickel 200, Zirconium 702/705, Inconel 600, Carbon Steel |
| Configuration | Benchtop & Mobile (Vehicle-Mounted) |
| Stirring | Non-Stirred (Static Reaction Vessel) |
| Compliance | Designed to ASME BPVC Section VIII Div. 1, PED 2014/68/EU, ISO 9001 Manufacturing Environment |