PerkinElmer
Filter
Showing 1–30 of 82 results
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | LPC500 + Avio500 |
| Application | Elemental Analysis & Particle Counting in Lubricants |
| Sample Volume | <1 mL per dual analysis |
| Cycle Time | ≤45 seconds per sample |
| Brand | PerkinElmer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Mode Flame/GF-AAS |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + AC Zeeman |
| Spectral Resolution | 0.1 nm |
| Sensitivity | Flame (Cu): ≤0.02 µg/mL |
| GF-AAS (Cd) | ≤5.0×10⁻¹³ g |
| Precision (RSD) | Flame (Cu): ≤0.45% |
| GF-AAS (Cd) | ≤3.0% |
| Detection Limit | Flame (Cu): ≤0.003 µg/mL |
| GF-AAS (Cd) | ≤1.0×10⁻¹² g |
| Baseline Stability | ≤0.002 A/30 min (static) |
| Lamp Turret | 8-position Auto-rotating |
| Graphite Furnace | Transversely Heated |
| Magnetic Field | AC Zeeman, 0.6–1.1 T adjustable in 0.1 T increments |
| Optional Features | Integrated Graphite Furnace Viewing System |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | ARVO X3 |
| Condition | Factory-Refurbished |
| Configuration | Complete System with Onboard Software, Filter Wheels, and Standard Optical Modules |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 200 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Gas Consumption | <8 L/min Ar (typical operational mode) |
| Startup Time | <5 minutes from cold start to analysis-ready |
| Dual-View Capability | Axial and Radial Simultaneous Observation without Sensitivity Loss |
| Linear Dynamic Range | Up to 9 orders of magnitude |
| Detector | Back-Illuminated CCD with On-Chip Background Correction |
| Plasma Technology | Flat Plate™ RF Generator and PlasmaShear™ Air-Based Tail Flame Elimination |
| Torch Orientation | Vertical, Tool-Free Adjustable Base with Interchangeable Injector Tubes |
| Software Platform | Syngistix for ICP-OES (21 CFR Part 11 Compliant) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Argon Consumption | <10 L/min (typical operational mode) |
| Plasma Orientation | Dual-View (Axial & Radial) |
| Plasma Technology | Flat Plasma™ |
| Background Correction | Real-Time Synchronous Background Correction |
| Detection Capability | Multi-element, simultaneous quantitative analysis of metals and some non-metals in liquid samples |
| Software Platform | Syngistix™ for ICP-OES |
| Brand | PerkinElmer |
|---|---|
| Model | Avio 550 |
| Origin | Imported |
| Configuration | Refurbished Unit |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Plasma Observation | Dual-view (Axial and Radial) |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Nebulization System | 4-channel, 12-roller peristaltic pump |
| Plasma Torch Design | Vertical, tool-free, maintenance-free torch with integrated tail-flame cutoff |
| Argon Consumption | Ultra-low |
| Diagnostic Capability | Real-time plasma imaging via integrated color plasma camera |
| Data Acquisition | Universal Data Acquisition (UDA) — full-wavelength, simultaneous, time-resolved detection |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio 550/560 |
| Pricing | Upon Request |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Configuration | Dual-View (Axial and Radial) |
| Detection Technology | Solid-State CCD Detector Array |
| Gas Consumption | Ultra-Low Argon Flow (<10 L/min typical plasma gas) |
| Torch Design | Vertical, Tool-Free, Maintenance-Free Plasma Torch with Integrated Tail-Flame Suppression |
| Optical System | Flat-Field Echelle Spectrometer with UV-Visible Wavelength Coverage (165–900 nm) |
| Pump System | 4-Channel, 12-Roller Peristaltic Pump |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Camera Integration | Integrated Color Plasma Torch Imaging System for Real-Time Torch & Injector Monitoring |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio® 550 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Orientation | Vertical Torch Configuration |
| Software Platform | Syngistix™ for ICP |
| Sample Introduction System | Scott/Cross-Flow Nebulizer with Cyclonic Spray Chamber |
| Optional Capability | HF-Compatible Sample Handling |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Clarus 580 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Not Specified |
| Oven Ramp Rate | Not Specified |
| Cooling Rate | Not Specified |
| Carrier Gas Flow Range & Control | Not Specified |
| Carrier Gas Pressure Range & Control | Not Specified |
| Injector Maximum Operating Temperature | Not Specified |
| Injector Pressure Setting Range | Not Specified |
| Injector Total Flow Setting Range | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Clarus 590 / Clarus 690 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal (Food, Pharmaceuticals, Petrochemicals, Environmental Analysis) |
| Software Platform | TotalChrom™ Chromatography Data System (CDS) |
| Regulatory Compliance Support | 21 CFR Part 11, GLP/GMP Audit Trail Capabilities |
| Automation Platform | TurboMatrix™ MultiPrep Autosampler (Liquid, Headspace, SPME) |
| Flow Control Technology | Swafer™ Micro-Channel Pneumatic Control |
| Detector Options | FID, TCD, ECD, NPD, FPD, PID |
| Inlet Types | Split/Splitless, PTV, Cold On-Column, Packed Column |
| Column Oven | Patented concentric exhaust design (Clarus 690) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Clarus 680 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Not Specified |
| Oven Ramp Rate | Not Specified |
| Oven Cool-Down Rate | Not Specified |
| Carrier Gas Flow Range & Control | Not Specified |
| Carrier Gas Pressure Range & Control | Not Specified |
| Injector Maximum Operating Temperature | Not Specified |
| Injector Pressure Setting Range | Not Specified |
| Injector Total Flow Setting Range | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Clarus 680 GC |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Clarus SQ 8 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC/MS Configuration | Conventional Gas Chromatography–Mass Spectrometry System |
| Mass Range | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Scan Speed | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Mobile Environmental Monitoring System |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DMA 8000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –196 °C to 600 °C (with LN₂ cryogenic cooling) |
| Frequency Range | 0.01–300 Hz |
| Cooling Rate | ≤15 min from ambient to –190 °C |
| Liquid Nitrogen Consumption | ~1 L per typical low-temperature DMA run |
| Sample Modes | Dual/Triple Cantilever, 3-Point Bending, Tension, Compression, Shear, and TMA Mode |
| Humidity Control Range | 10–90 % RH (optional humidity generator) |
| Optical Access | Quartz furnace viewport for in-situ visual monitoring and UV-curable sample testing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 4000 / DSC 6000 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –100 °C to 600 °C (with optional cryogenic and high-temp accessories) |
| Temperature Accuracy | ±0.1 °C (traceable to NIST standards) |
| Heating/Cooling Rate | 0.1–100 K/min (programmable in 0.1 K/min increments) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DSC 8000 |
| Simultaneous Sample Capacity | Multiple |
| Instrument Type | Power-Compensated DSC |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | 0.01 °C/min to 300 °C/min |
| Dynamic Heat Flow Range | ±800 mW |
| Furnace Material | Platinum-Iridium Alloy |
| Modulated DSC (MDSC®) | Standard |
| Cooling Options | Two-stage mechanical cooler, three-stage mechanical cooler, automated liquid nitrogen cooling |
| Dual Digital Mass Flow Controllers | Standard |
| Optional Accessories | 96-position autosampler, high-pressure cell (up to 600 psi), UV photo-DSC module, isolated sample chamber for hazardous materials |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DSC 8500 |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | up to 750 K/min (controlled), >1000 K/min (free cooling) |
| Heat Flow Dynamic Range | ±800 mW |
| Calorimetric Accuracy | < ±0.2% |
| Sensitivity | 0.18 µW |
| Data Acquisition Rate | up to 100 Hz |
| Standard Features | Dual-channel digital mass flow controllers, automated lid, integrated cooling accessory |
| Optional Accessories | 96-position autosampler, high-pressure DSC cell, isolated DSC module, photo-DSC unit, DSC–Raman hyphenated system |
| Brand | PerkinElmer |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FL 6500 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 1, 2.5, 5, 10, 20 nm |
| Resolution | 1.0, 2.5, 5, 10, 20 nm |
| Sensitivity | >750:1 (RMS) |
| Dispersion Element | Grating |
| Light Source | Pulsed Xenon Lamp |
| Brand | PerkinElmer |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FL 8500 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 1, 2.5, 5, 10, 20 nm |
| Resolution | 1.0, 2.5, 5, 10, 20 nm |
| Sensitivity | 4000:1 (RMS), 1000:1 (Peak-to-Peak) |
| Dispersion Element | Holographic Grating |
| Excitation Source | Continuous Xenon Arc Lamp |
| Maximum Scan Speed | 60,000 nm/min |
| Footprint | 66 cm (26 in) width |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FLEXAR™ |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Pump Configuration | Dual Binary Solvent Delivery |
| Maximum Pressure Rating | >18,000 psi |
| Integrated Piston Wash Function | Yes |
| Real-Time Pressure Monitoring | Supported via Chromera CDS |
| Gradient Delay Volume | Minimized for UHPLC compatibility |
| Column Oven Temperature Range | Ambient to 90 °C (optional extension to 110 °C) |
| UV-Vis Detector Wavelength Range | 190–900 nm (with optional diode array) |
| Data Acquisition Rate | Up to 100 Hz |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready architecture |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | GC 2400 |
| Instrument Type | Laboratory Gas Chromatograph-Mass Spectrometer |
| Application Scope | General-Purpose GC-MS Analysis |
| Key Feature | Integrated Split Touchscreen Control Interface |
| Detection Technology | Quadrupole Mass Spectrometry (MS 2400 SQ) with Clarifi™ Detector |
| Sample Introduction | Smart Liquid Autosampler with Pressure-Balanced Injection |
| Safety System | Integrated Hydrogen Sensor |
| Source Technology | SMARTsource™ Replaceable Ion Source |
| Software Platform | Simplicity™ GC/MS Workstation |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin Category | Imported |
| Model | GCMS 2400 System |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Gas Chromatography Configuration | Conventional GC-MS Platform |
| Software | SimplicityChrom™ Chromatography Data System (CDS) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HS2400 Headspace Sampler |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Software Compatibility | Third-party Chromatography Data Systems (CDS), including Waters Empower™ |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 1050+ |
| Optical Design | Double-beam |
| Detector Type | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–3300 nm |
| Wavelength Accuracy | ±0.025 nm (UV-Vis), ±0.02 nm (NIR) |
| Automation | Motorized wavelength scanning and accessory control |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 2 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system, fully tested and calibrated |
| Compliance | Meets original factory specifications for optical performance and photometric accuracy |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LAMBDA 265 |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | <0.03% T at 340 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAMBDA 365 |
| Instrument Configuration | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | Selectable (0.5, 1, 2, 5, or 20 nm) |
| Wavelength Accuracy | ±0.1 nm |
| Stray Light | <0.02% T at 340 nm |
| Brand | PerkinElmer |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Configuration | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Spectral Bandwidth | 0.5 nm to 20 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.02 nm |
| Stray Light | <0.00004% T at 220 nm and 340 nm |
| Absorbance Range | Up to 4.0 A |
| Automation Level | Fully Automated Wavelength Scanning & Parameter Control |
| Compliance | ASTM E275, ISO 9001, USP <857>, FDA 21 CFR Part 11 Ready |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Instrument Type | Imported |
| Model | LAMBDA 465 |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | <0.03% T at 340 nm |
| Automation | Motorized Wavelength Scanning |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp |
| Regulatory Compliance | FDA 21 CFR Part 11–enabled Software |
