Pfeiffer Vacuum
Filter
Showing all 20 results
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ACP 120 |
| Pump Type | Oil-Free Dry Scroll Vacuum Pump |
| Ultimate Pressure | ≤3 × 10⁻² mbar |
| Pumping Speed | 95 m³/h |
| Motor Power | 3 kW |
| Noise Level | <65 dB(A) |
| Weight | 205 kg |
| Inlet Flange | DN 50 |
| External Dimensions (L×W×H) | 1000 × 600 × 700 mm |
| Maintenance Interval | ~17,000 operating hours |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM 142 S |
| Detection Limit (He) | 1 × 10⁻⁸ Pa·m³/s |
| Measurement Range (He) | 1 × 10⁻⁷ to 1 mbar·L/s |
| Forepump | Oil-Sealed Rotary Vane Pump |
| Detectable Gas | ⁴He |
| Operating Temperature | 0–45 °C |
| Acoustic Noise Level | < 57 dB(A) |
| Dimensions (W × D × H) | 517 × 357 × 420 mm |
| Warm-up Time | 2 min |
| Detection Mode | Sniffer (Probe-Based) |
| Weight | 55 kg |
| Standard Probe | 5 m Flexible Hose with 9 cm Rigid Nozzle |
| Power Supply Options | 110–130 V AC (North America) or 200–240 V AC (Europe) |
| Interface | RS-232 / USB / Optional PLC Integration |
| Display Language Options | English, French, German, Chinese |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany (manufactured in Germany, distributed globally) |
| Model | ASM 340 |
| Detection Principle | Quadrupole Mass Spectrometry with Helium Carrier Gas |
| Minimum Detectable Leak Rate | ≤5 × 10⁻¹² mbar·L/s (helium) |
| Operating Mode | Positive-Pressure Sniffing & Vacuum-Coupled Testing |
| Pumping System | Integrated Turbomolecular Pump + Forepump |
| Mass Filter | 4-amu Resolution Quadrupole Analyzer |
| Response Time | <100 ms (typical) |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface | RS-232, Ethernet, Analog Output (0–10 V) |
| Software Compatibility | Pfeiffer VacuGraph® PC Control Suite |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer | Pfeiffer Vacuum GmbH |
| Type | Imported Industrial Leak Detector |
| Model | ASM 306 S |
| Detection Gases | Helium (He) and Hydrogen (H₂) |
| Minimum Detectable Leak Rate (He) | 1 × 10⁻⁷ mbar·L/s |
| Minimum Detectable Leak Rate (H₂) | 5 × 10⁻⁷ mbar·L/s |
| Warm-up Time | 2 min |
| Response Time | < 1 s |
| Sniffer Probe Flow Rate | 300 sccm ± 10% |
| Noise Level | 55 dB(A) |
| Interfaces | RS-232, Digital I/O, Fieldbus Options |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Max. Power Consumption | 300 VA |
| Weight | 22 kg |
| Dimensions (L×W×H) | 350 × 305 × 421 mm |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ASM 340 |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5 × 10⁻¹³ Pa·m³/s |
| Startup Time | 3 min |
| Response Time | < 1 s |
| Maximum Inlet Pressure | 2500 Pa |
| Helium Purge Speed | 2.5 L/s |
| Leak Rate Display Range | 1 × 10⁻³ to 1 × 10⁻¹³ Pa·m³/s |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340WET |
| Detection Principle | Helium-Specific Quadrupole Mass Spectrometry |
| Operating Mode | Vacuum (Hard-Line) Mode |
| Pumping Configuration | Integrated with ACP 28 Dry Scroll Vacuum Pump |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface | RS-232 / Ethernet (Optional), Analog Output (0–10 V) |
| Minimum Detectable Leak Rate | ≤5 × 10⁻¹² mbar·L/s (He) |
| Response Time | < 0.5 s (typical) |
| Mass Filter | Quadrupole with 4 amu resolution at 4 He peak |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM-2000 |
| Detection Principle | Helium Mass Spectrometry (Quadrupole) |
| Measurement Methods | Vacuum Mode & Sniffer Mode |
| Quantitative Sensitivity (Vacuum Mode) | 1×10⁻⁸ – 1×10⁻⁵ mbar·L/s |
| Qualitative Sensitivity (Sniffer Mode) | >1×10⁻⁵ mbar·L/s |
| Calibration | Automatic, traceable to NIST-certified standard leak |
| Operating Temperature | 15–25 °C |
| Relative Humidity | 30–80 % RH |
| Power Supply | 90–250 V AC, 50–60 Hz |
| Typical Power Consumption | 3,750 W |
| Compressed Air (ISO 8573-1 Class 1.3.1) | 4.5–10 bar(g) |
| Helium Supply Pressure | 0.5–8 bar(g) |
| Nitrogen Supply Pressure | 0.5–8 bar(g) |
| User Interface | 10" multi-touch full-HD color display |
| Software | GMP-compliant Windows 10 OS with 4-tier user access control, PDF report generation (test, calibration, audit trail), FDA 21 CFR Part 11 readiness |
| Connectivity | 1× LAN, 2× USB 3.0, 1× HDMI |
| Dimensions (L×W×H, incl. trolley) | 1,409 × 575 × 1,194 mm |
| Weight (incl. trolley) | 140 kg |
| Acoustic Noise Level | <53 dB(A) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Calibration System Pro |
| Calibration Range | 1013 hPa to 10⁻³ hPa |
| Flange Configuration | PS A30 110 (4×DN 16 ISO-KF, 2×DN 25 ISO-KF, 1×DN 40 ISO-KF, 1×DN 40 CF) / PS A30 111 (5×DN 16 ISO-KF, 2×DN 25 ISO-KF, 2×DN 40 ISO-KF) |
| Nitrogen Pumping Speed | 67 L/s |
| Forevacuum Pump Speed (50 Hz) | 2.5 m³/h |
| Ultimate Pressure | < 1 × 10⁻⁷ hPa |
| Gas Flow Control Range | 5 × 10⁻⁶ to 1 × 10³ hPa·L/s |
| Operating Temperature | +5 °C to +40 °C (cooling-dependent) |
| Weight | 66 kg (standard configuration) |
| Dimensions (L×W×H) | 700 × 639 × 593 mm |
| Compliance | ISO 3567, DAkkS-DKD-R 6-2, EN ISO 12100, EN 60204-1, CE (2006/42/EC & 2014/30/EU) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniStar / ThermoStar |
| Principle | Quadrupole Mass Filter |
| Response Time | ≤2 s |
| Mass Range Options | 1–100 amu, 1–200 amu, 1–300 amu |
| Inlet Capillary Temperature | Up to 350 °C |
| Inlet Material | Stainless Steel (OmniStar) or Fused Silica (ThermoStar) |
| Pumping System | MVP dry diaphragm pump + HiPace turbomolecular pump |
| Software | PV MassSpec (qualitative & quantitative analysis) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiCube 80 Eco |
| Pump Type | Oil-Free Turbo-Molecular Pump System |
| Ultimate Pressure | <1×10⁻⁸ Pa (without gas ballast) |
| Pumping Speed (N₂) | 67 L/s at DN 63 CF-F inlet |
| Pre-vacuum Pump | MVP 015-2 multi-stage diaphragm pump |
| Forepump Speed | 1 m³/h (16.67 L/min, N₂) |
| Ultimate Forepressure | <1×10⁻² Pa |
| Cooling | Convection-cooled (standard) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Max. Power Consumption | 170 W |
| Sound Pressure Level | ≤50 dB(A) |
| Inlet Flange | DN 63 CF-F |
| Outlet Flange | G 1/8" |
| Dimensions (W×D×H) | 352 × 301 × 302 mm |
| Weight | 13.5 kg |
| Compliance | CE, RoHS, ISO 9001 certified |
| Control Interface | Integrated digital controller with status LEDs and RS-232/USB option |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | HiPace 300 |
| Nominal Pumping Speed for N₂ | 260 L/s |
| Protection Rating | IP54 |
| Certifications | UL/CSA, CE, compliant with EN 61000-6-2/-4 and EN 61000-3-2 |
| Integrated Drive Electronics | TC 400 |
| Cooling | Integrated water-cooling system |
| Mounting | Flange-compatible (DN 100 CF/KF optional) |
| Application Class | High and ultra-high vacuum (UHV) systems |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HiPace 80 Neo |
| Instrument Type | Turbomolecular Pump |
| Product Type | Oil-Free Pump |
| Pumping Speed (N₂) | 67 L/s |
| Ultimate Pressure | ≤2.2 × 10⁻⁸ mbar (typical in high vacuum, corrected from erroneous “22 mbar” — consistent with HiPace 80 Neo datasheet) |
| External Dimensions (W × H × D) | 97 × 86 × 129 mm |
| Weight | 1.7 kg |
| Motor Power Supply | 110 V AC, 50/60 Hz (integrated drive electronics) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HPA 220 / SPM 220 |
| Pricing | Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ModuLine Gauge |
| Interface Options | PROFIBUS |
| Sensor Types | Capacitance Manometer (TPR series), Cold Cathode Ionization Gauge (IKR series) |
| Operating Temperature Range | –40 °C to +80 °C |
| Weight | 0.14–0.65 kg |
| Vacuum Range | 10⁻¹¹ mbar to 10³ mbar (depending on sensor module) |
| Sealing | Metal-sealed variants available |
| Radiation & EMI Resistance | Yes |
| Application Domain | Particle accelerator beamlines, UHV/XHV research systems, industrial vacuum process monitoring |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | MVP015-2 |
| Power Supply | 24 V DC |
| Noise Level | <50 dB(A) |
| Operating Temperature Range | 5–40 °C |
| Pumping Speed (at 100 mbar) | 1.5 m³/h |
| Ultimate Vacuum (with gas ballast open) | ≤10 mbar |
| Ultimate Vacuum (with gas ballast closed) | ≤3 mbar |
| Motor Type | Electronically Commutated DC Motor (ECM) |
| Stages | Two-stage |
| Gas Ballast | Magnetic Solenoid Valve |
| Maintenance Interval | Up to 2 years under typical lab conditions |
| Weight | ~6.2 kg |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniControl |
| Measurement Principle | Vacuum Pressure Monitoring and Pump Control via RS-485 and Analog Interfaces |
| Enclosure Rating | IP20 |
| Operating Temperature | 0°C to +50°C |
| Power Supply Options | 100–240 V AC ±10%, 47–63 Hz |
| Power Consumption | 300 W (OmniControl 200) / 411 W (OmniControl 300) / 522 W (OmniControl 400) |
| Output Voltages | 24 V DC (200/300) or 48 V DC (400) |
| Max Output Current | 11.4 A (200) / 15 A (300) / 8.33 A (400) |
| Display | 3.5-inch capacitive touchscreen |
| Mounting Options | Rack-mountable, desktop, or portable configurations |
| Compliance | Designed for integration with Pfeiffer Vacuum RS-485–enabled pumps (HiPace, HiScroll, HiLobe, MVP) and digital vacuum gauges |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | OMNISTAR™ / THERMOSTAR™ |
| Pricing | Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 251 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa |
| Vacuum Interfaces | KF 25, CF 40, KF 40 |
| Accuracy | ±30% (1×10⁻⁸ to 100 hPa) |
| Repeatability | ±5% |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | up to 150 °C |
| Power Supply | 15.0–30.0 V DC |
| Max. Power Consumption | ~2 W |
| Output Signal | 0–10.5 V analog voltage |
| Weight | ~700 g |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 361 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa (calibrated for air or N₂) |
| Vacuum Port Options | KF 25, CF 40, KF 40 |
| Repeatability | ±1% of reading (1×10⁻⁸ to 100 hPa) |
| Bakeout Temperature | ≤150 °C |
| Anode Material | Molybdenum |
| Flange Material | 1.4435 stainless steel |
| Compliance | CE, RoHS, EN 61326-1 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 280 |
| Measurement Principle | Pirani |
| Range | 5 × 10⁻⁴ to 1000 hPa |
| Vacuum Interface | KF 16 (DN 16 ISO-KF) |
| Output Signal | 2.2–8.5 V DC |
| Supply Voltage | 14–30 V DC |
| Filament Material | Tungsten |
| Housing Material | Stainless Steel |
| Electrical Feedthrough | Glass |
| Operating Temperature | 5–60 °C |
| Bakeout Temperature | 80 °C (250 °C optional) |
| Accuracy | ±15% of reading (10⁻³–100 hPa) |
| Repeatability | ±2% of reading (10⁻³–100 hPa) |