POWEREACH
Filter
Showing all 29 results
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FH801 |
| Pricing | Available Upon Request |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | FJ3003 |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Analog Input Channels | 2 (auto-ranging: ±0.2 V, ±2 V, ±20 V) |
| Input Impedance | >10 MΩ |
| Sampling Rate | 100 MS/s |
| Display & Measurement Resolution | 4 significant digits |
| Temperature Measurement Accuracy | ±0.01 °C |
| Temperature Control Range | 15 °C above ambient to 100 °C |
| Temperature Setpoint Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Output Actuation | Zero-crossing triggered thyristor |
| Control Output | 5-step power output (max. 300 W) |
| Electrical Isolation | Analog-to-digital and overvoltage protection integrated |
| Compliance | Designed for academic lab environments |
| Brand | POWEREACH |
|---|---|
| Model | JB04 |
| Origin | Shanghai, China |
| Light Source | 532 nm green laser (20 mW or 50 mW) |
| Laser Intensity Adjustment | 1–100% continuous |
| Objective Lens | Japanese MS-01 zoom objective, working distance 90 mm, magnification 700–1100 px/mm |
| Spatial Resolution | 2 µm |
| Incident Angle Range | 45°–60° |
| Polarization System | High-grade optical prism polarizer |
| Imaging Sensor | High-sensitivity CCD with electronic shutter |
| Image Acquisition | CG400 frame grabber card |
| Operating System Compatibility | Windows XP (32-bit), Windows 7 (32-bit) |
| Interface | RS232 serial port, native PCI slot required |
| Software | Proprietary GUI-based acquisition and analysis software |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JC2000D1 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.01° |
| Sample Stage Dimensions | 70 × 100 mm (expandable) |
| Image Magnification | 50–318 pixels/mm |
| Surface/Interfacial Tension Range (Pendant Drop Method) | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Maximum Sample Size | 70 mm × 100 mm × 25 mm |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JC2000Y Series |
| Sample Stage | Circular, φ50–φ81 mm diameter, 5–30 mm thickness |
| Application Focus | Contact angle measurement on convex spherical lenses (glass & optical resin) |
| Compliance | Designed for ISO 19403-2, ASTM D7334, and GB/T 24368-2009 surface wettability testing protocols |
| Brand | POWEREACH |
|---|---|
| Model | JCJ04 |
| Type | Gravitational Sedimentation Particle Size Analyzer |
| Origin | Shanghai, China |
| Measurement Principle | Gravitational sedimentation (Stokes’ law-based) |
| Particle Size Range | 1–60 µm |
| Maximum Sample Mass Capacity | 0–100 g (selectable) |
| Sensitivity | 0.1 mg |
| Data Acquisition Interval | 0.5 s |
| Sample Vessel | 500 mL calibrated glass cylinder |
| Calibration Weights | 0.5 g, 10 g, 50 g, 100 g |
| Data Output | Real-time sedimentation curve, D10/D50/D90, mean diameter, particle size distribution histogram, cumulative distribution, error estimation |
| Software Functions | Auto-zero, tare, self-calibration, alarm threshold setting, curve storage/retrieval, statistical analysis, report generation & printing |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JDS05C |
| Instrument Type | Electromechanical Triaxial Testing System |
| Max Biaxial Tensile Force | 4.0–5.0 kN (per axis) |
| Max Punching Force (Z-axis) | 2.0 kN |
| Displacement Resolution | 0.02 mm |
| Crosshead Speed Range | 0.8–2.0 mm/s |
| Max Travel per Axis | 300 mm |
| Load Cell Accuracy | ±1 N (with overload protection) |
| High-Speed Imaging | 30–200 fps CCD camera |
| Operating Environment | 8–30 °C, RH < 80% |
| Software Control | Real-time speed, stroke, and data acquisition via proprietary Windows-based interface |
| Compliance | Configurable to ASTM D5034, D5035, D638, ISO 13934-1, ISO 13935-1, GB/T 3923.1, and textile-specific GLP workflows |
| [Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JF99A |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Washburn Capillary Penetration Method |
| Contact Angle Range | 0–90° (calculated, relative) |
| Contact Angle Resolution | ±0.3° |
| Pressure Measurement Range | 0–330 mbar |
| Pressure Accuracy | ±0.16 mbar |
| Quartz Tube Dimensions | OD 10 mm / ID 8 mm or ID 6 mm |
| Sample Particle Size Requirement | ≤200 mesh (74 µm) |
| Surface Tension Range | 0.01–2000 mN/m |
| Image Magnification | 0.7×–5× (50–318 pixel/mm) |
| Stage Size | 120 × 120 mm |
| Power Consumption | <20 W |
| Dimensions (W×D×H) | 295 × 240 × 260 mm] |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JH11X |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Potentiostatic Range | ±2 V |
| Current Range | ±2 mA / ±20 mA (dual-range) |
| Potential Resolution | 0.001 V |
| Current Resolution | 0.001 mA |
| Reference Electrode Input Impedance | ≥10¹² Ω |
| Cell Voltage Range | ±13 V |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 320 × 215 × 130 mm |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JJ2000B2 |
| Measurement Range (Interfacial Tension) | 1×10⁻⁶ mN/m to 100 mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | <2% (100 mN/m to 10⁻² mN/m), <8% (10⁻³ mN/m to 10⁻⁶ mN/m) |
| Rotational Speed Range | 2000–10,000 rpm |
| Speed Stability | ±0.1% |
| Temperature Control Range | Ambient to 95 °C |
| Capillary Inner Diameter | 2 mm / 4 mm |
| Contact Angle Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Image Magnification | 50–318 px/mm |
| Frame Rate | Up to 30 fps (continuous), programmable interval capture (1–3600 s) |
| Power Consumption | <50 W |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JJ2000C |
| Measurement Range | 10⁻⁶–100 mN/m |
| Temperature Control Range | 5–95 °C (PID) |
| Temperature Display Range | 0–99.9 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotational Speed | 1,000–10,000 rpm (±5 rpm) |
| Image Capture | USB-triggered monochrome camera, 60 fps |
| Spatial Resolution | 0.001 mm |
| Sample Tube ID | 2 mm & 4 mm high-purity quartz |
| Interface | USB or RS-232 |
| Data Export | Native Excel (.xlsx), BMP image archive |
| Compliance | ASTM D971, ISO 6295, USP <1042>, GLP-ready audit trail support |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JJ2000H2 |
| Measurement Range | 100 to 1×10⁻⁶ mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | ±0.01 mN/m |
| Measurement Principle | Image-based spinning drop analysis — high-speed CCD captures droplet morphology under controlled centrifugal rotation |
| Temperature Control Range | Ambient to 150 °C |
| Pressure Rating | 0.7 MPa |
| Maximum Rotational Speed | 14,000 rpm |
| Speed Control Precision | ±5 rpm |
| Heating System | PID-controlled stainless-steel jacketed heater with Pt100 sensor |
| Imaging System | 60 fps monochrome CCD (752 × 480 pixels), motorized XYZ-stage with 0.01 mm resolution, 0.7–4.5× zoom lens |
| Sample Tube Options | φ2 mm and φ4 mm quartz capillaries |
| Interface | USB 2.0 or RS232 |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JK99 Series |
| Measurement Range | 0–500 mN/m (JK99F & JK99M: 0–1000 mN/m) |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sensor Type | Imported Japanese load cell (JK99B/C/D), METTLER high-precision balance sensor (JK99M) |
| Temperature Sensing Accuracy | ±0.1 °C |
| Power Supply | AC 220 V ±5 V, <150 W |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JK99M1 |
| Measurement Range | 0–999.999 mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | ±0.01 mN/m |
| Methods | Du Noüy Ring Method (40–50 mL sample volume) & Wilhelmy Plate Method (20–30 mL sample volume) |
| Sampling Interval | 1–5 s (Plate), 50–200 s (Ring) |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986, SY/T 5370–1999 |
| Sensor | High-precision 0.1 mg electromagnetic balance (METTLER-origin system) |
| Data Acquisition Rate | 10 Hz (standard), 50 Hz (optional) |
| Temperature Sensing Accuracy | ±0.1 °C |
| Platform Vertical Travel | 0–30 mm (standard), up to 100 mm (optional) |
| Positional Repeatability | ±0.1 mm (±1 µm with optional sensor) |
| Power Supply | AC 220 V ±5%, <150 W |
| Operating Humidity | 30–85% RH |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JMD04A |
| Instrument Type | Electromechanical Burst Tester |
| Maximum Burst Force | 50 kgf (490.3 N) |
| Displacement Resolution | 0.01 mm |
| Compliance | ASTM D3786, ISO 13938-1, GB/T 7742.1, BS EN ISO 13938-1 |
| Software | Windows-based control & analysis suite with real-time force-displacement curve acquisition, auto peak detection, statistical reporting (mean, SD, CV%), and export to CSV/PDF |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JMD04C |
| Maximum Burst Force | 5000 kgf (49.05 kN) |
| Test Speed Range | Adjustable |
| Stroke Range | Adjustable |
| Displacement Resolution | Not specified |
| Instrument Type | Electromechanical Burst Testing Machine |
| Compliance | Designed for ASTM D3787, ISO 13938-1, GB/T 7742.1, and related textile & membrane burst standards |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JOS06 |
| Temperature Range | Ambient to 300 °C |
| Sample Area | 25 mm diameter |
| Quartz Disk Gap Adjustment | 0.05–2 mm |
| Temperature Accuracy | ±1 °C (±0.1 °C within 100 °C) |
| Shear Modes | Oscillatory (0.01–10 Hz) and Steady-State (0.001–500 rpm, controllable down to 0.01 rpm) |
| Optical System | Transmitted light + polarized light paths |
| Imaging Resolution | 25 pixels/µm |
| CCD Stage | 3-axis motorized translation |
| Objective Working Distance | 7 mm |
| Observation Window | Large-aperture viewport |
| Temperature Control | Dual-zone heated quartz disks with Pt100 sensors |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94 |
| Measurement Principle | Microelectrophoresis (Video-Based Particle Tracking) |
| Compliance | GB/T 32668–2016 (National Standard for Colloidal Particle Zeta Potential Analysis – Electrophoretic Method) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Operating Temperature Range | Ambient to 35 °C |
| Zeta Potential Accuracy | Systematic error ≤5% |
| pH Range | 1.6–13.0 (typical operational range: 2.0–12.0) |
| Sample Volume per Test | 0.5 mL |
| Optical Magnification | Up to 1200× |
| Imaging System | USB Digital CCD with Customized Micrometer Grid Calibration |
| Electrode Configuration | Integrated Ag, Pt, and Ti/POM electrodes in open-cell electrophoresis chamber |
| Voltage Control | Adjustable DC bias with polarity reversal (0.30–1.20 s interval) |
| Temperature Compensation | Real-time thermistor-based ambient temperature sampling |
| Software Platform | Unified cross-model analysis suite with GLP-compliant data logging and audit trail capability |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixels/µm |
| System Accuracy | ±5% relative error (per GB/T 32668-2016 validation protocol) |
| Particle Size Applicability | 0.5–20 µm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V AC, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H2-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixel/µm |
| Particle Size Range | 0.5–20 µm |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Compliance | GB/T 32668–2016 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94J-1K20X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| System Accuracy | ≤5% systematic error |
| Particle Size Applicability | 0.1–10 μm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JS94J2-1K20X |
| Zeta Potential Range | ±200 mV (typical, per GB/T 32668-2016 calibration protocol) |
| pH Range | 1.6–13.0 (standard operation: 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| Microscope System | WDK Japan high-magnification optical module, working distance 7 mm |
| System Accuracy | ≤5% relative error (per ISO 13099-2:2012 validation methodology) |
| Particle Size Applicability | 0.1–10 μm (aqueous & organic dispersions) |
| Power Consumption | <150 W, 220 V / 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94K-3H20X |
| Zeta Potential Range | ±200 mV (typical, inferred per ISO 13099-2) |
| pH Range | 1.6–13.0 (standard operation 2.0–12.0, resolution 0.1) |
| Temperature Range | Ambient to 35 °C (measurement resolution 0.1 °C) |
| Particle Size Compatibility | 0.2–50 µm (aqueous dispersions) |
| Optical Resolution | 1.93–12 pixels/µm (motorized zoom optical system) |
| Power Consumption | <150 W |
| Compliance | GB/T 32668–2016, ISO 13099-2:2012, ASTM D7825–14 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94K2-3H20X |
| Zeta Potential Range | ±200 mV (typical, system-limited) |
| pH Range | 1.6–13.0 (standard operation 2.0–12.0, resolution 0.1) |
| Temperature Range | Ambient to 35 °C (readout resolution 0.1 °C) |
| Particle Size Compatibility | 0.2–50 µm |
| Optical Resolution | 1.93–12 pixels/µm (motorized zoom optical system) |
| Power Consumption | <150 W |
| Compliance | GB/T 32668–2016 (General Rules for Zeta Potential Analysis of Colloidal Particles by Electrophoresis) |
| System Accuracy | ±5% relative error (per certified reference dispersions under controlled conditions) |
| Sample Volume per Measurement | 0.5 mL |
| Voltage Polarity Switching Interval | 0.30–1.20 s (adjustable) |
| Measurement Time per Cycle | 3–10 s |
| Light Source | Low-power semiconductor blue/green LED (non-thermal, near-field illumination) |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JSC08 |
| Pricing | Available Upon Request |
| Brand | POWEREACH |
|---|---|
| Model | JWQ06 |
| Application | Textile Fiber Mechanical Testing |
| Measurement Principle | Controlled Oscillatory Bending under Tension |
| Sample Type | Individual Filaments (Aramid, Carbon, Glass, UHMWPE) |
| Adjustable Bend Radius | Yes |
| Environmental Operation | Ambient to Elevated/Low Temperatures |
| Tension Monitoring | Real-time Dynamic Tension Measurement during Bending Cycles |
| Control Interface | PC-based Software with RS232/USB Connectivity |
| Compliance Context | ASTM D3822, ISO 5079, GB/T 14337, ISO 1973 (adapted for bending fatigue extension) |
| Software Features | Cycle Counting, Load-Time Curve Logging, Pre-tension Calibration, Angle & Frequency Parameterization |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JZ95MS Series (MS-01, MS-02, MS-40, MS-60, MS-80, MS-160) |
| Zoom Mechanism | Continuous zoom system |
| Illumination | Reflected (MS-01, MS-40–MS-160) or coaxial incident (MS-02) |
| Objective Magnification Range | 0.75×–4.5× (MS-01/MS-02), 6.5×–40× (MS-40), 10×–60× (MS-60), 13×–80× (MS-80), 26×–160× (MS-160) |
| Image Resolution | 600 px/mm (MS-01/MS-02), 6–24 px/µm (MS-40 to MS-160) |
| Working Distance | 90 mm (MS-01/MS-02), 8.5–7.5 mm (MS-40–MS-160) |
| Aperture Control | Manual iris ring |
| Software Compliance | ISO 9276-1, GB/T 15445 |
| Operating System Support | Windows 95/98 (legacy environment |
| Brand | POWEREACH |
|---|---|
| Model | NDJ-1 |
| Type | Analog Rotational Viscometer |
| Portability | Benchtop (with integrated stand) |
| Operating Environment | Ambient temperature (10–35 °C) |
| Viscosity Range | 1–100,000 mPa·s |
| Rotors | Standard set includes #1–#4 |
| Speed Settings | 6, 12, 30, 60 rpm |
| Accuracy | ±5% for Newtonian fluids |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions (W×D×H) | 400 × 370 × 150 mm |
| Compliance | Designed per GB/T 2794–2013 (Chinese national standard for viscometer calibration), compatible with ISO 2555 and ASTM D2196 test methodologies |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-4 |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±5% (for Newtonian fluids) |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions | 320 × 260 × 170 mm |
| Included Rotors | #1, #2, #3, #4 |
| Compliance | Designed for GLP-compliant routine viscosity monitoring in QC/QA and R&D environments |