| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DLabs-MRS |
| Price Range | USD 14,000 – 115,000 |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1100 |
| Temperature Control Range | Ambient +6°C to 399°C |
| Oven Ramp Rate | 0–30°C/min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 200°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Temperature Accuracy | ±0.1°C |
| Column Oven Temperature Gradient | ±1.5% |
| TCD Sensitivity | ≥4000 mV·mL/mg (n-hexadecane) |
| TCD Noise | ≤0.04 mV |
| TCD Baseline Drift | ≤0.2 mV/30 min |
| FID Detection Limit | ≤8×10⁻¹² g/s (n-hexadecane) |
| FID Noise | ≤0.02 mV |
| FID Baseline Drift | ≤0.2 mV/30 min |
| Dimensions (L×W×H) | 562×550×492.5 mm |
| Weight | 44 kg |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 185–900 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm) |
| Wavelength Repeatability | ≤0.05 nm (at D₂ line, 656.1 nm) |
| Spectral Bandwidth | Continuously Adjustable from 0.1 to 5.0 nm |
| Stray Light | ≤0.00004%T (NaI, 220 nm) |
| Stray Light | ≤0.00002%T (NaNO₂, 360 nm) |
| Photometric Range | –8 to +8 Abs |
| Baseline Flatness | ±0.0005 Abs |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3%T (>1.0 Abs) |
| Photometric Repeatability | ≤0.001 Abs (0–0.5 Abs), ≤0.002 Abs (0.5–1.0 Abs), ≤0.1%T (>1.0 Abs) |
| Drift | ≤0.1%T/h |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TU-1901 / TU-1900 |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190 nm – 900 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | 0.1 nm, 0.2 nm, 0.5 nm, 1.0 nm, 2.0 nm, 5.0 nm |
| Stray Light | ≤0.01%T at 220 nm (NaI), ≤0.05%T at 360 nm (NaNO₂) |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3%T (0–100%T) |
| Photometric Range | –4.0 to +4.0 Abs |
| Baseline Flatness | ±0.001 Abs |
| Baseline Drift | 0.0004 Abs/h (at 500 nm, 0 Abs, after 2 h warm-up) |
| Photometric Noise | ±0.0004 Abs |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | Continuously Variable from 0.1 to 5.0 nm (0.1 nm increments) |
| Stray Light | ≤0.01% T at 220 nm (NaI), ≤0.05% T at 360 nm (NaNO₂) |
| Baseline Flatness | ±0.001 Abs |
| Drift | ≤0.1%/h |
| Dimensions | 610 × 570 × 300 mm |
| Weight | 39 kg |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Y3600 |
| Price Range | USD 7,000–14,000 |
| Chamber Volume | ≥180 L |
| Heating Power | Water Heating ≥9,000 W |
| Wash Temperature Range | 5–40 °C |
| Compatible Cleaning Agents | Alkaline Detergents & Acidic Neutralizers |
| External Dimensions (L×W×D) | 605×705×900 mm |