Renishaw
Filter
Showing 31–39 of 39 results
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | SP25M |
| Probe Type | Dual-mode (scanning + touch-trigger) |
| Sensor Integration | Integrated capacitive scanning sensor + mechanical trigger sensor |
| Compatible Shank Lengths | 20 mm to 400 mm |
| CMM Interface | Standard M3, M4, or HSK shank options (per OEM integration) |
| Operating Principle | Capacitive displacement sensing (scanning mode) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | TP200 |
| Probe Type | Modular Trigger (Kinematic) Probe for CMMs |
| Sensor Technology | Micro-strain Gauge |
| Repeatability | < 0.5 µm (3σ, under controlled conditions) |
| Overtravel Force Options | Standard Force (SF) or Low Force (LF) |
| Interface | PI 200 (Proprietary Renishaw CMM Interface) |
| Toolchanging Compatibility | SCR200 Automatic Probe Change Rack |
| Electronics | ASIC-based Signal Conditioning and Debounce Circuitry |
| Operating Life | > 10⁶ triggers (typical, per module) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | Virsa Raman Analyzer |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 50–4000 cm⁻¹ |
| Spectral Resolution | <2.5 cm⁻¹ |
| Spatial Resolution | XY <0.5 µm, Z <2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | <±0.1 cm⁻¹ |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | XL-80 |
| Measurement Principle | Stabilized HeNe laser interferometry (wavelength 632.991 nm, traceable to SI meter) |
| System Accuracy | ±0.5 ppm (0–40 °C, compensated) |
| Resolution | 0.001 µm |
| Max Linear Velocity | 4.0 m/s |
| Sampling Rate | 50 kHz |
| Measurement Range | 0–80 m |
| Laser Warm-up Time | ~6 min |
| Environmental Compensation | XC-80 sensor (updates compensation every 7 s) |
| Laser Source Stability | ±0.05 ppm |
| Beam Height & Optical Compatibility | Fully compatible with ML10 optics and mounts |
| Software Suite | LaserXL™ (step-by-step metrology workflows), QuickViewXL™ (real-time display) |
| Warranty | 3 years standard, extendable to 5 years |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | XL80 |
| Measurement Speed | up to 4.0 m/s |
| Sampling Rate | up to 50 kHz |
| Linear Accuracy | ±0.5 ppm (0–40 °C) |
| Laser Stabilization Accuracy | ±0.05 ppm |
| Resolution | 0.001 µm |
| Maximum Linear Measurement Range | 80 m |
| Warm-up Time | ~6 minutes |
| Environmental Compensation | via XC-80 sensor (7-second update interval) |
| Wavelength Reference | Stabilized HeNe laser (traceable to SI meter) |
| Optical Compatibility | Fully backward-compatible with ML10 interferometer optics |
| Software | LaserXL™ (step-by-step machine tool verification), QuickViewXL™ (real-time display) |
| Portability | Total system weight <15 kg (laser head + XC-80 + cables + power supply + sensors) |
| tripod weight | 6.2 kg |
| Warranty | 3-year standard, extendable to 5 years |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | XR20-W |
| Weight | ~1 kg (unit device), <7 kg (full system in Peli™ case) |
| Measurement Accuracy | ±1 arcsecond |
| Power | Rechargeable battery |
| Connectivity | Bluetooth® 4.0 |
| Compatible Laser Interferometers | XL-80 (standard), ML10 (USB interface version forthcoming) |
| Compliance | Fully calibrated and certified per ISO 10360 and ISO 230-4 prior to shipment |
| Software | Renishaw XCalibrator v3.x with ISO 230-4 / ASME B5.54 preconfigured test templates, automatic alignment calibration, GLP-compliant audit trail |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RESOLUTE™ |
| Encoder Type | True Absolute, Fine-Pitch Optical Encoder |
| Maximum Rotational Speed | 36,000 rpm |
| Position Resolution | 27-bit (134,217,728 counts/rev) |
| Output Interface | BiSS-C, EnDat 2.2, or proprietary Renishaw serial protocol |
| Contamination Resistance | Engineered for high-dust, oil-mist, and condensation-prone industrial environments |
| Compliance | Designed to support ISO 9001 manufacturing processes |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RLP40 |
| Transmission | 2.4 GHz FHSS (Frequency-Hopping Spread Spectrum) |
| Receiver Compatibility | Renishaw RMI Series |
| Communication Range | Up to 15 m in typical machine tool environments |
| Environmental Rating | IP67 (probe body), IP54 (stylus assembly) |
| Operating Temperature | 0 °C to 40 °C |
| Battery Life | ≥12 months (typical usage, CR2032 coin cell) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | TONiC™ |
| Maximum Speed | 10 m/s |
| Resolution | down to 5 nm |
| Subdivision Error | < ±30 nm |
| Operating Temperature | up to 70 °C |
| Compliance | RoHS, WEEE |
| Output Options | 1 Vpp analog, digital via 15-pin D-sub connector with diagnostics |
| IN-TRAC™ Reference Mark | Integrated bidirectional optical zero mark |
| Signal Stability | Enhanced by AGC and optical filtering |
| Installation | Tool-less, self-aligning readhead with dual diagnostic LEDs |