RuboLab
Filter
Showing all 6 results
| Brand | RuboLab |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DASH |
| Hydrogen Generation Principle | Rare-Earth Alloy-Based Reversible Hydride Absorption/Desorption |
| Output Flow Rate | 150 L/min (STP) |
| Output Pressure Range | 0–20 MPa |
| Hydrogen Purity | 99.9999% (v/v) |
| Power Consumption | Application-Dependent — Typically <1 kW for thermal management during desorption cycles |
| Compliance | CE, PED 2014/68/EU, ASME BPVC Section VIII Div. 2 (design basis), ISO 16111:2017 (Hydrogen Technologies – Gaseous Hydrogen Storage) |
| Brand | RuboLab |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | DASH-1 |
| Hydrogen Generation Principle | Rare-Earth Alloy-Based Solid-State Hydrogen Storage & Release |
| Output Flow Rate | 150 L/min |
| Output Pressure Range | 0–70 MPa |
| Hydrogen Purity | 99.9999% |
| Power Consumption | Application-Dependent (Typical System-Side Electrical Input for Compression/Control: <5 kW) |
| Brand | RuboLab |
|---|---|
| Origin | Germany |
| Model | Infrasorb |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Dynamic (Flow) Method |
| Number of Analysis Stations | 12 |
| Pressure Range | Ambient (1 bar) |
| Measurement Gas | n-Butane, CO₂ (optional: NH₃, H₂S, VOCs e.g., methanol, ethanol) |
| Sample Volume | 0.1 mL or ≤30 mg |
| Gas Flow Rate | up to 500 mL/min (N₂-equivalent) |
| Analysis Time | <5 min (typ. 3 min) |
| Temperature | 298 K |
| Detection Method | Non-contact, disturbance-free infrared thermography |
| Repeatability | High (validated per ISO 9277 and ASTM D3663 protocols for comparative adsorption screening) |
| Brand | RuboLab |
|---|---|
| Origin | Germany |
| Model | RuboHyCo |
| Hydrogen Generation Principle | Metal Hydride-Based Thermal Desorption |
| Output Flow Rate | 800 mL/min (per compression station) |
| Output Pressure | 20 MPa (2,900 psi) or 70 MPa (10,000 psi) |
| Hydrogen Purity | 99.9999% |
| Power Consumption | Not specified (device is thermally actuated |
| Brand | RuboLab |
|---|---|
| Origin | Germany |
| Model | RuboSORP 50 / 150 / 350 / 700 |
| Measurement Principle | Magnetic Suspension Balance (Gravimetric) |
| Temperature Range | −196 °C to 500 °C |
| Pressure Range | 0–700 bar |
| Ultimate Vacuum | 1 × 10⁻⁷ mbar |
| Brand | Rubolab |
|---|---|
| Model | Smart Filtration Kit |
| Origin | Spain |
| Instrument Type | Online Monitoring System |
| Measured Parameters | Foam Characteristics, Particle Count (ISO/NAS Code), Demulsibility Indicator (via OilWear Sensor Platform), Optional Water Content (ppm) |
| Flow Control | Integrated Flow Meter & Regulator |
| Compliance | ISO 4406, ISO 11171, ASTM D892, ASTM D2711, ISO 6247 |
| Software | Rubolab OilWear™ Cloud Platform with Audit Trail & Exportable CSV/Excel Reports |
| Certifications | CE, RoHS, Designed for GLP/GMP Environments |