Sanotac
Filter
Showing all 6 results
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Biolot 50 |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Types | UV-Vis Absorbance Detector, Conductivity Detector, Evaporative Light Scattering Detector (ELSD) |
| Detection Wavelength Range | 190–800 nm |
| Flow Rate Range | 0.01–50 mL/min |
| Pressure Range | 0–20 MPa |
| Gradient Accuracy | ±0.5% ABS (dual-pump system) |
| Conductivity Range | 0–999.9 mS/cm |
| pH Range | 0–14 |
| Fraction Collector Capacity | 2 × 60 tubes (15 mm Ø × 150 mm H) |
| Software Compliance | FDA 21 CFR Part 11, CFDA GxP |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Pilot600 |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Pump Material | 316L Stainless Steel (PEEK optional) |
| Flow Rate Range | 0.01–600.00 mL/min (gradient mode) |
| Flow Accuracy | ±0.5% |
| Maximum Pressure | 10 MPa |
| Pressure Pulsation | ≤0.2 MPa |
| Gradient Types | Step, Linear, Real-time Adjustable |
| Minimum Gradient Increment | 1% |
| Detection Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | 0–2 AU |
| UV-Vis Light Source | Imported Deuterium + Tungsten Lamps |
| Sample Injection | Manual 10 mL loop (customizable loops available) |
| Injection Modes | Solid or Liquid Loading |
| Power Supply | 220 V ±10%, 50 Hz |
| Control Interface | Graphical UI via USB/RS-232 |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | QP-0010 |
| Instrument Type | Quaternary Pump |
| Maximum Pressure | 42 MPa |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Brand | Sanotac |
|---|---|
| Model | S-0150 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Isocratic Pump |
| Max. Operating Pressure | 50 MPa (7,250 psi) |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Flow Increment | 0.001 mL/min |
| Fluid Path Materials | 316L Stainless Steel, Sapphire, PTFE, Ceramic |
| Connection | 1/16″ Standard Fittings |
| Display | 256×64 Dot Matrix LCD with Backlight |
| Communication | RS232 & USB (standard), RS485/RS422 (optional) |
| Protocols | Sanotac Proprietary, Modbus RTU/ASCII |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | SP1020 |
| Max. Operating Pressure | 20 MPa |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Increment | 0.01 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.2 MPa |
| Display | 256×64 dot-matrix backlit LCD |
| Control Interface | Front-panel keypad + RS232/USB open communication protocol compliant with ASTM E1381 and FDA 21 CFR Part 11 audit trail requirements |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TS0530 |
| Flow Rate | 0.01–50.00 mL/min |
| Pressure Rating | ≤30 MPa |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±1 °C |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.2 MPa |
| Wetted Materials | 316L stainless steel, ruby, PTFE, PEEK, ceramic |
| Communication | RS232/RS485, Modbus RTU, digital I/O |
| Display | 256×64 dot matrix backlit LCD |
| Power Supply | 85–264 VAC, 50 Hz |