SCChengyi
Filter
Showing all 12 results
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DSWY-1 |
| Pricing | Available Upon Request |
| Sensor Included | Yes |
| Brand | SCChengyi |
|---|---|
| Model | PHG-1 |
| Temperature Range | Ambient to 100°C |
| Max Heating Power | 350 W |
| Heating Time (Ambient → 38°C) | <10 min |
| Operating Voltage | AC 220 V, 50 Hz |
| Temperature Control Accuracy | ≤0.2°C |
| Display Resolution | 0.1°C |
| Dual Display | Actual & Set Temperature |
| Dual Preheating Reservoirs | 45 mL and 200 mL |
| Preheating Glass Tubes | Three 20 mL + One 60 mL Quartz Tubes |
| Leakage Protection | 10 mA Trip Current |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | RM6240T |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | HS-4 |
| Temperature Range | -15 to +95 °C |
| Temperature Stability | ±0.02 °C |
| Heating Power | 1 kW |
| Cooling Capacity | Integrated refrigeration system |
| Bath Volume | 7 L |
| Opening Dimensions | 148 × 149 mm |
| External Dimensions | 540 × 400 × 400 mm |
| Pump Flow Rate | 6 L/min |
| Internal/External Circulation | Yes |
| Weight | 36 kg |
| Power Supply | 220 V, 50–60 Hz |
| Brand | scchengyi |
|---|---|
| Origin | Sichuan, China |
| Model | JP-06A |
| Current Measurement Range | 1×10⁻³ A to 1×10⁻⁹ A (F.S.) |
| Sensitivity | 5×10⁻⁸ mol/L for Cd²⁺ (Linear Sweep Polarography) |
| Potential Range | −4000 mV to +4000 mV (min. step: 0.15 mV) |
| Scan Rate | 0.05–1 V/s |
| DME Drop Period | 1–1000 s |
| Resolution | < 2.5 mV |
| Anti-Interference Ratio (for pre-reduced species) | 10⁴ : 1 |
| Repeatability Error | < 0.1 % |
| Range Switching Error | < 0.1 % |
| ADC | 24-bit |
| DAC | 16-bit |
| Power Consumption | < 10 W |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | NXS-11B |
| Viscosity Range | 2.8–1.78×10⁷ mPa·s |
| Shear Stress Range | 27.67–21,970 Pa |
| Shear Rate Range | 1.23–996 s⁻¹ |
| Speed Range | 5.6–360 rpm |
| Repeatability | ±1% FS (Newtonian fluids) |
| Construction | Stainless steel coaxial cylinder system |
| Instrument Type | Coaxial Cylinder Rotational Viscometer |
| Portability | Benchtop and handheld operation capable |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | QFS601 |
| Measurement Range | -80 to +20 °C dew point (≈ 0.5–23,632 µL/L H₂O) |
| Accuracy | ≤ ±1 °C |
| Response Time | <30 s (63%), <60 s (90%) for rise at DP < -40 °C |
| Output Signals | 4–20 mA, RS232 or USB (user-specified) |
| Power Supply | AC 220 ± 22 V, 50–60 Hz / Internal rechargeable battery (DC) |
| Operating Conditions | Gas Temp < +60 °C, Pressure < 2 MPa, Recommended Flow Rate: 200 mL/min |
| Dimensions | 260 × 170 × 300 mm (W × H × D) |
| Brand | scchengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | USI-1AB |
| Product Type | Online Dew Point Moisture Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–40 °C (ambient) |
| Supply Gas Pressure | <100 kPa |
| Accuracy | ±5% of reading |
| Repeatability | <0.08 µL/L at sample moisture ≤260 µL/L |
| Range | 0–1000 µL/L (ppmv) |
| Response Time (t₆₃) | ≤3 min |
| Output Signals | 0–10 mV and 4–20 mA |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Sample Flow Rate | 100 mL/min (measurement), 1 L/min (bypass) |
| Dimensions | 380 × 300 × 170 mm |
| Weight | 6.5 kg |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YLG-1 |
| Quotation | Upon Request |
| Startup Time | ~20 min |
| Cooling Power | 200 W at 25°C |
| Outlet Dew Point | +3°C |
| Dew Point Stability | ±0.5 K |
| Dimensions (W×D×H) | 235 × 375 × 310 mm |
| Power Supply | AC 220 V, 50 Hz |
| Sample Gas Inlet/Outlet Connection | 6 mm OD × 1 mm wall tubing |
| Condensate Drain Connection | 4 mm OD × 1 mm wall tubing |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | ZDZ-4JA |
| Measurement Principle | Thermal Conductivity (Pirani) |
| Pressure Range | 1.0 × 10⁵ Pa to 1.0 × 10⁻¹ Pa |
| Vacuum Port | KF16 |
| Display | 4.3-inch TFT Touchscreen |
| Sensor Channels | 4 independent Pirani sensor inputs |
| Sensor Type | CY-1Z resistive gauge (included, 4 pcs) |
| Cable Length | 3 m (standard) |
| Dimensions (H×W×D) | 110 × 103 × 230 mm |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Weight | ~3 kg |
| Accuracy | ±20% of reading (typical, within specified range) |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SQG-1 |
| Pricing | Upon Request |
| Temperature Range | Ambient to 100°C |
| Max Heating Power | 350 W |
| Warm-up Time (Ambient → 38°C) | <10 min |
| Operating Voltage | AC 220 V, 50 Hz |
| Temperature Control Accuracy | ≤0.1°C |
| Display Resolution | 0.1°C |
| Dual Display | Actual & Set Temperature |
| Bath Capacity | 20 mL (±1 mL precision) |
| Preheating Rack | Holds five 20 mL glass tubes + accommodates ≥200 mL auxiliary reservoir |
| Modular Bath Design | Detachable for cleaning or replacement |
| External Circulation & Gas Supply Unit | Decoupled from bath chamber to eliminate pump-induced vibration |
| Adjustable Gas Flow Rate | Compatible with ambient air or externally supplied O₂ |
| Integrated Tissue Suspension Assembly | One-dimensional precision micrometer stage with synchronized transducer–tissue movement |
| Leakage Protection | 10 mA residual-current device |
| Waste Collection | Dedicated waste reservoir included |
| Brand | SCChengyi |
|---|---|
| Model | XY-2 |
| Category | Animal Metabolism Detection System |
| Origin | Sichuan, China |
| Measurement Capabilities | Blood Pressure (Systolic/Diastolic), Peripheral Capillary Oxygen Saturation (SpO₂), Pulse Rate |
| Operating Modes | Manual, Automatic, Continuous Monitoring |
| SpO₂ Range | 0–99% |
| Pulse Rate Range | 0–255 bpm |