SCHOTT
Filter
Showing all 5 results
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVS370 |
| Measurement Principle | Capillary Flow (Ubbelohde & Ostwald-type) |
| Time Range | 0.01–9999.99 s (resolution: 0.01 s) |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (positive pressure mode) / 0.35–5000 mm²/s (vacuum mode) |
| Timer Accuracy | ±0.01% |
| Temperature Equilibration Time Setting | 0–20 min (in 1-min increments) |
| Replicate Runs | 1–10 per sample |
| Interface | RS-232C |
| Power Supply | 115/230 VAC, 50/60 Hz, 30 W |
| Housing | Anodized aluminum |
| Dimensions (W×H×D) | 225 × 205 × 320 mm |
| Weight | 5.4 kg |
| Compatible Viscometers | DIN Ubbelohde, ASTM Ubbelohde, DIN Micro Ubbelohde, Micro Ostwald, Cannon-Fenske Routine, TC-Ubbelohde, TC-Micro Ubbelohde |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVS370 |
| Measurement Principle | Capillary efflux time (kinematic viscosity) via photometric and thermal-conductivity detection |
| Pressure Modes | Positive pressure & vacuum aspiration |
| Timer Resolution | 0.01 s |
| Time Range | 0.01–9999.99 s |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (cSt) under positive pressure |
| Timer Accuracy | ±0.01% |
| Pump Control | Microprocessor-regulated ViscoPump II (up to 4 units per chassis) |
| Temperature Equilibration Delay | 0–20 min (user-configurable) |
| Replicates per Sample | 1–10 |
| Interface | RS-232C |
| Power | 115/230 VAC, 50/60 Hz, 30 W |
| Enclosure | Powder-coated aluminum |
| Dimensions (W×H×D) | 225 × 205 × 320 mm |
| Weight | 5.4 kg |
| Compatible Viscometers | DIN Ubbelohde, ASTM Ubbelohde, DIN Micro Ubbelohde, Micro Ostwald, Cannon-Fenske Routine, TC-Ubbelohde, TC-Micro Ubbelohde |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVSPro |
| Measurement Principle | Capillary Flow (ASTM D445, ISO 3104, IP 71) |
| Kinematic Viscosity Range | 0.35–1200 mm²/s at ambient temperature |
| Accuracy | ±0.01% of reading + ±1 digit |
| Replicate Runs | 1–99 per sample |
| Temperature Equilibration Time | 0–99 min |
| Detection Methods | Dual-mode — Opto-electronic (for transparent/clear liquids) and Thermal Conductivity (TC) sensing (for opaque, dark, or highly viscous samples) |
| Sample Handling | Fully automated liquid handling with programmable injection sequence |
| Interface | RS-232/USB for PC integration |
| Compliance | Designed to meet ASTM D445, ISO 3104, ISO 17025 requirements for accredited viscosity testing laboratories |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | SLR |
| Instrument Type | Magnetic Stirrer |
| Heating Method | Infrared |
| Max. Stirring Volume | 10 L (H₂O) |
| Stirring Speed Range | 100–1100 rpm (adjustable in 10 rpm increments) |
| Heating Plate Material | Ceramic Glass |
| Max. Heating Temperature | ~550 °C |
| Heating Power | 0.9 kW |
| Plate Dimensions (L×W) | 235 × 235 mm |
| Heating Zone Diameter | Φ155 mm |
| Dimensions (W×H×L) | 370 × 240 × 85 mm |
| Weight | ~3.8 kg |
| Max. Load Capacity | 25 kg |
| Temperature Control Accuracy | ±2–5 °C |
| External Temperature Sensor Support | Pt1000 (optional) |
| Temp. Setting/Display Resolution | 1 °C |
| IP Rating | IP20 |
| Operating Ambient | 10–40 °C, ≤85% RH |
| Power Supply | 115/230 V, 50/60 Hz |
| Safety Features | Overtemperature auto-shutdown, residual heat warning, thermal shock resistance up to 700 °C |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Burette Capacity | 20 mL (DURAN® borosilicate glass, Class 3, UV-protected jacket) |
| Valve System | PTFE/ECTFE three-way safety valve |
| Tubing | UV-resistant FEP tubing with PTFE check valves |
| Dispensing Accuracy | ±0.03–0.07% (burette), ±0.1–0.2% (system) |
| Display | Backlit LCD (69 × 39 mm, 64 × 128 characters), auto-adjusting brightness |
| Electrode | Dual platinum electrode, polarizing voltage adjustable from 5–200 mV (default 100 mV) |
| Current Measurement Range | 0–99.9 µA, resolution 0.1 µA |
| Interfaces | Dual RS-232 ports (PC/printer + balance/expansion) |
| Calibration Modes | Pure water, certified standard, sodium tartrate dihydrate (with solvent/gas blank correction) |
| Reporting | On-screen results + printable reports (Basic, Standard, GLP-compliant) |
| Calculation Units | ppm, mg, mg/L, mg/pc |
| Stirring Speed | 50–1000 rpm |
| Power Supply | AC 230 V, 50/60 Hz, 30 VA |
| Dimensions (W × H × D) | 310 × 265 × 205 mm (including titration unit) |
| Weight | 3.2 kg |
| Compliance | DIN 12650 Part 5, EN ISO 8655-3 |
| Qualification Support | DQ/IQ/OQ/PQ documentation available on request |