SCION
Filter
Showing all 16 results
| Brand | Scion |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Gas Chromatograph |
| Models | 436-GC, 456-GC |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Cooling Rate | ~4.5 min from 400 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Detector Data Acquisition Rate | 600 Hz |
| Column Oven Configuration | Dual-channel (436-GC), Quad-channel (456-GC) |
| Injector Types Supported | Split/Splitless, PTV, Cool-on-Column, Direct Injection |
| Flow Control Mode | Constant Linear Velocity (CLV) |
| System Software | Compass CDS (integrated) |
| Compliance | ASTM, UOP, EN, ISO, GPA, USP methods |
| Brand | Scion |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic Instrument |
| Model | 436i |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | –100 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Maximum Cool-Down Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Interface |
| Mass Range | 1–1200 m/z |
| Resolution | 0.7–4 amu (full width at half maximum, FWHM) |
| Detection Limit (IDL) | <1 fg (octafluoronaphthalene, OFN) |
| Scan Speed | ≥14,000 amu/sec |
| Oven Ramp Rate | ≥125 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Ion Source | High-Temperature Inert Dual-Filament Electron Ionization Source |
| Pre-filter | Dual-Axis Pre-quadrupole |
| Detector | Long-Life Extended-Dynamic-Range Electron Multiplier |
| Vacuum System | High-Capacity Turbomolecular Pump (≥300 L/s N₂) |
| Flow Control | Digital Electronic Flow Control (EFC) on All Inlets and Detectors |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | 456i |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | –100 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Maximum Cool-Down Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments B.V. |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | Scion |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 8500-GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments |
| Instrument Type | Single Quadrupole GC-MS |
| GC Platform Options | SCION 8300 / 8500 |
| Mass Range | 1–1200 Da |
| Resolution | 0.7–4 Da (FWHM) |
| Sensitivity (EI Full Scan) | ≥1500:1 S/N for 1 pg Octafluoronaphthalene |
| Scan Speed | 20,000 Da/s |
| Oven Ramp Rate | Up to 180 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Ion Source | Axially Oriented, Ultra-Inert Design |
| Vacuum System | High-Capacity Turbo-Molecular Pump (Standard) |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments (a part of Antec Scientific Group) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-Coupled |
| Mass Range | 1–1200 Da |
| Resolution | 0.7–4.0 Da (full width at half maximum, FWHM) |
| Sensitivity | ≥1500:1 S/N for 1 pg Octafluoronaphthalene (OFN) at m/z 272 |
| Scan Speed | 30,000 Da/s |
| Oven Ramp Rate | Up to 180 °C/min |
| Pressure Control Precision | ±0.001 psi |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Artemis 6000 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.01–10.0 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 0–500 µL |
| Autosampler Temperature Control | Yes |
| Post-Column Reactor Temperature Range | Ambient to 180 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Compass CDS |
| Price Range | USD 35,000 – 85,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Injection Positions | 100 × 2 mL vials |
| Injection Volume | 0.1–50 µL (standard), 5–2250 µL (optional) |
| Column Oven Temperature Range | Ambient to 85 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Primaide / Chromaster |
| Pricing | Available Upon Request |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | HT3 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | Up to 300 °C, 1 °C Incremental Control |
| Valve & Transfer Line Temperature Range | Up to 300 °C, 1 °C Incremental Control |
| Temperature Control Accuracy | ±0.05 °C |
| Sample Loop Volume | 1 mL Silco-coated loop standard |
| optional loops | 100 μL, 250 μL, 300 μL, 500 μL, 2 mL, 3 mL, 5 mL |
| Vial Capacity | 60 positions |
| Vial Size | 22 mL |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC6000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose analytical platform |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Operating Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Autosampler Capacity | 200 positions (1.5 mL vials) |
| Optional Configurations | 128 positions (4 mL vials) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Wavelength Ranges | UV-Vis: 190–900 nm |
| DAD | 190–900 nm |
| Fluorescence (FL) | Ex 200–850 nm / Em 250–900 nm |
| Data Acquisition Rate | Multi-step selectable |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC6000-DAD |
| Instrument Category | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical platform |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure Rating | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional Trays | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| DAD Wavelength Range | 190–900 nm |
| Spectral Acquisition Rate | Multi-step adjustable |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic UHPLC System |
| Model | LC6000-FLD |
| Instrument Type | Ultra-High Performance Liquid Chromatograph with Fluorescence Detection |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Excitation Wavelength Range | 200–850 nm |
| Emission Wavelength Range | 250–900 nm |
| Data Acquisition Frequency | Multi-step adjustable |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Versa |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | 200 °C, Temperature Increment: 1 °C, Stability: ±0.1 °C |
| Valve Oven Temperature Range | 200 °C, Increment: 1 °C |
| Sample Loop Volume | 1 mL Silco-coated loop (optional loops: 100 μL, 250 μL, 300 μL, 500 μL, 2 mL, 3 mL, 5 mL) |
| Vial Capacity | 20 positions |
| Vial Size | 22 mL |