Senbe
Filter
Showing all 27 results
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | SEN-RD3000 |
| Pricing | Upon Request |
| Brand | Senbe |
|---|---|
| Model | A650 |
| Type | Benchtop Energy-Dispersive X-ray Fluorescence (EDXRF) Spectrometer |
| Detector | Silicon Drift Detector (SDD), Resolution: 129 ± 5 eV |
| X-ray Tube | 50 W, 5–50 kV / 0–1000 µA |
| Measurable Elements | Na (11) to U (92) |
| Detection Limit | ppm-level |
| Quantification Range | 0.0001% – 99.99% (matrix-dependent) |
| Sample Form | Solid, Powder, Liquid |
| Vacuum Capability | Integrated Vacuum System for Light Element Enhancement (Mg, Al, Si, P, S) |
| Cooling | Peltier-based Electric Refrigeration |
| Safety | Triple-layer Radiation Shielding, Interlocked Sample Chamber, Real-time Beam Monitoring |
| Software | Proprietary EDXRF Analysis Suite with Fundamental Parameters (FP), Empirical Coefficient, and Matrix Correction Algorithms |
| Compliance | Designed to meet IEC 61000-6-3 (EMC), IEC 61000-6-4, and GB/T 18806–2002 (Chinese EDXRF Standard) |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BM-6000 |
| Instrument Type | Online Analyzer |
| Biological Agent | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature Range | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Temperature Control Accuracy | ≤ ±1 °C |
| Batch Capacity | 10 samples per cycle |
| Measurement Time | 5 min (default assay duration) |
| Measurement Principle | Dual-optical-path bioluminescence inhibition assay |
| Compliance Standard | ISO 11348-3:2007 & GB/T 15441–1995 |
| Photometric Range | 0–200% relative light units (RLU) |
| Reproducibility (CV) | ≤10% |
| Pure Water Light Loss | ±3% |
| Sample Injection Precision | ≤2% (syringe-based volumetric delivery) |
| Data Storage | ≥2 years at 1-hour measurement interval |
| Communication Interface | RS-232 / RS-485 (Modbus RTU protocol) |
| Analog Output | 4–20 mA DC (≤300 Ω load) |
| Display | 12.1″ capacitive touchscreen LCD |
| Dimensions (W×D×H) | 560 × 430 × 1600 mm |
| Weight | ~20 kg |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CCZ-20 |
| Pricing | Available Upon Request |
| Compliance | GB/T 3836.18–2017 (Intrinsically Safe Electrical Systems for Explosive Atmospheres), GB/T 20964–2007 (Dust Samplers), Q/HHD 0103–2016 (Enterprise Standard), BMRC Respirable Dust Separation Curve Conformance |
| Protection Rating | IP54 |
| Construction | High-strength ABS engineering plastic housing with anti-humidity, anti-dust, and anti-static treatment |
| Flow Stability | Low pulsation, high load capacity, stable volumetric flow |
| Operational Interface | PVC membrane switch panel |
| Certification | MA (Mine Safety Approval) and Explosion-Proof Verification Certificate |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Compass 4294 Plus |
| Pricing | Upon Request |
| Analytical Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Detector | High-Resolution Peltier-Cooled Fast Silicon Drift Detector (FSDD), FWHM <130 eV (Mn Kα) |
| Max Input Count Rate | 500,000 cps |
| Vacuum Capability | Integrated Miniature Vacuum Pump |
| Measurement Time | 130–300 s (user-configurable) |
| Sample Forms | Liquids, Solids, Powders |
| Operating Temperature | −20 to 50 °C |
| Dimensions (L×W×H) | 270 × 320 × 230 mm |
| Sample Chamber Size | 170 × 110 × 17 mm |
| Weight | 10.5 kg |
| Display | 8-inch Touchscreen (1280 × 800), Windows 10 OS |
| Data Interfaces | USB, Bluetooth, Wi-Fi, GPS |
| Safety | Interlocked Radiation Shielding, Real-Time Dose Indicator |
| Calibration | Auto-startup Calibration, Factory-Preloaded Calibration Curves (Low-S: 0–100 ppm |
| High-S | 0.01–5 wt% |
| Cl | 0–100 ppm) |
| Compliance Standards | GB/T 17040–2008, GB/T 17060–1998, GB/T 380–1977, GB/T 17411–2015, SH/T 0253–1992, ASTM D4294, ISO 8754, ISO 20847, IP 336, ASTM D6445, IP 496, ASTM D7220 |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DP8600 |
| Measurement Principle | Full-Spectrum Absorption Spectrophotometry |
| Wavelength Range | 190–1100 nm |
| Measurable Parameters | COD, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Nitrogen, Total Nitrogen, Total Phosphorus |
| Sample Holders | Cuvette (standard), 16 mm and 25 mm test tubes |
| Light Sources | Imported Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Detector | Imported Photodiode Array |
| Display | 7-inch TFT color touchscreen (bilingual: English/Chinese) |
| Optical Functions | Photometric Mode, Quantitative Analysis, Standard Curve Construction, Kinetic Scanning, Full-Spectrum Scan |
| Data Storage | USB flash drive support |
| Custom Curve Capability | Yes |
| Optional Accessories | 5 cm and 10 cm sample holders |
| Brand | Senbe |
|---|---|
| Model | DSJ-LJ |
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Pricing | Available Upon Request |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | EDXP3600 |
| Price | Upon Request |
| Excitation Source | 50 kV / 200 µA Ag-target micro-focus X-ray tube, end-window configuration, ≤4 W power match |
| Detector | 25 mm² fast Silicon Drift Detector (SDD), 0.3 mil Be window, energy resolution ≤125 eV (Mn Kα), Peltier-cooled |
| MCA | 4096-channel digital pulse processor |
| Elemental Range | Na (11) to U (92) |
| Analysis Modes | Alloy, RoHS, Soil, Water |
| Soil LODs (SiO₂ matrix) | Pb <5 mg/kg, As <3 mg/kg, Cr <15 mg/kg, Cu <10 mg/kg, Zn <2 mg/kg, Ni <5 mg/kg, Mn <10 mg/kg, Hg <1 mg/kg, Cd <3 mg/kg |
| Water LODs (aqueous matrix) | Pb <1 mg/L, As <0.5 mg/L, Cr <2 mg/L, Cu <1 mg/L, Zn <2 mg/L, Ni <1 mg/L, Mn <2 mg/L, Hg <1 mg/L, Cd <1 mg/L |
| Quantification Time | 3–60 s (user-adjustable) |
| Repeatability | RSD <4% (for major elements in homogeneous alloys) |
| Collimation & Filters | 6 interchangeable filters + multiple collimators → 18 automatic combinations |
| Display | 5.5″ high-brightness capacitive touchscreen LCD |
| Processor | Intel quad-core @ 1.33 GHz |
| Memory | 2 GB RAM, 32 GB internal storage (expandable via microSD) |
| Connectivity | Wi-Fi 802.11 b/g/n, Bluetooth 4.0, USB 2.0, GPS module |
| Safety | Beam-on detection sensor, auto X-ray cutoff during air measurement |
| Weight | 1.5 kg (with battery) |
| Operating Environment | –20 °C to +50 °C, RH <90% non-condensing |
| Power | Rechargeable Li-ion, 6700 mAh, >6 h typical operation |
| Data Output | Excel, BMP, PDF reports |
| Compliance | Meets IEC 62471 (LED/X-ray safety), ISO 12885 (XRF safety guidance), and supports GLP/GMP audit trail requirements via timestamped, user-logged data export |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | FD216 |
| Sampling Method | Active Pump-Driven Sampling |
| Measurement Range (Air Radon) | 3–100,000 Bq/m³ |
| Minimum Detectable Activity | 3 Bq/m³ |
| Response Time (Air) | 30 min |
| Detector | ZnS(Ag) Scintillation Screen Coupled with Photomultiplier Tube (PMT) |
| Sensitivity | ≥0.68 cpm/(Bq·m⁻³) |
| Background Count Rate | ≤0.3 cpm |
| Repeatability Error | ≤5% (at 2000 Bq/m³, 65% RH, 25°C) |
| Stability | ≤10% drift over 8 h |
| Power Supply | Rechargeable Li-ion Battery (30 h continuous operation) or AC Adapter |
| Operating Temperature | −10 to +40 °C |
| Relative Humidity | ≤90% at +40 °C |
| Data Storage Capacity | 2000 records |
| Display | LCD |
| Dimensions | 330 × 210 × 170 mm |
| Weight | 5 kg (main unit) |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | IX2 AIR SE |
| Operating Temperature | Uncooled |
| Measurement Method | Non-contact |
| Application | Temperature Measurement |
| Detector Type | Single-element infrared detector |
| Temperature Range | -20°C to +150°C, 100°C to 550°C |
| IR Resolution | 256 × 192 |
| Pixel Pitch | 12 µm |
| Spectral Band | 7.5–14 µm |
| NETD | <40 mK @ 25°C, F1.0 |
| Frame Rate | 25 Hz |
| Lens Focal Length | 3.2 mm |
| FOV | 56° × 42° |
| IFOV | 3.75 mrad |
| Focus | Fixed |
| Minimum Focus Distance | 0.3 m |
| Accuracy | ±2°C or ±2% of reading (whichever is greater) |
| Color Palettes | 7 |
| Image Analysis Modes | Spot, Max/Min, 3 Custom Points/Lines/Boxes |
| Connectivity | Wi-Fi (up to 8 m), Bluetooth, USB-C |
| Battery | 1050 mAh |
| Runtime | ~2 h |
| Charging | USB Type-C |
| Weight | ~130 g |
| Dimensions | 135.6 × 41 × 29.1 mm |
| IP Rating | IP54 |
| Drop Resistance | 2 m |
| Shock/Vibration | 25 g (IEC 60068-2-27), 2.5 g (IEC 60068-2-6) |
| Operating Temp | -10°C to +50°C |
| Humidity | 10–90% RH (non-condensing) |
| Storage Temp | -20°C to +60°C |
| Certifications | CE, RoHS, Metrological Verification |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | MP5300 |
| Pricing | Available Upon Request |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | PF-3 |
| Instrument Type | Multi-Parameter Soil Analyzer |
| Optical System | LED-based photometer with interference filters |
| Wavelengths | 365 nm / 450 nm / 660 nm |
| Wavelength Accuracy | ±2 nm |
| Bandwidth at Half-Maximum | 10–12 nm |
| Light Source | High-stability LEDs |
| Detector | Silicon photodiode |
| Sample Format | 16 mm round cuvettes (VISOCOLOR® ECO and NANOCOLOR® pre-filled tubes) |
| Measurement Modes | VISOCOLOR® ECO and NANOCOLOR® test protocols |
| Data Storage | 50 measurement records |
| Display | Graphical LCD, 64 × 128 pixels |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | 3 × AA batteries (alkaline or rechargeable) / USB 5 V power input / optional internal rechargeable battery |
| Enclosure Rating | IP68 |
| Dimensions | 170 × 95 × 68 mm |
| Weight | 0.5 kg |
| Certifications | CE compliant |
| Warranty | 1 year |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SAI008 |
| Pricing | Upon Request |
| Measurement Principle | Hyperspectral Reflectance Analysis (400–1000 nm, 1 nm spectral resolution) |
| Measurable Parameters | COD, Ammonia-Nitrogen (NH₃-N), Total Phosphorus (TP), Total Nitrogen (TN), Chlorophyll-a, Turbidity, Secchi Depth, CODMn, Suspended Solids (SS), CDOM (optional), Attenuation Coefficient (optional) |
| Sampling Interval | Configurable down to 1 second |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SEN-320 |
| Instrument Type | Purity Analysis System |
| Imaging Sensor | 12 MP Color CMOS with Large Depth of Field |
| Backlight Panel | A3-size Ultra-thin Uniform LED Illuminator |
| Particle Diameter Range | 0.5–20 mm |
| Counting Speed | 1,200–20,000 seeds/min |
| Counting Accuracy | ≤ ±0.1–0.4% |
| Thousand-Seed Weight (TSW) Accuracy | ≤ ±0.5% |
| Morphometric Parameters Output | Length, Width, Aspect Ratio, Area, Equivalent Diameter, Perimeter, Bounding Rectangle |
| Image Processing | Auto-correction for Lens Distortion & Backlight Non-uniformity |
| Software Features | Customizable One-Click Analysis Protocols, Color/Shape Self-Learning Classification, Batch Adhesion Separation Algorithm, Barcode & RS232 Scale Integration |
| Data Export | Excel (.xlsx), Histograms (Size Distribution), Ranked Parameter Tables, Measurement Maps |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | SEN-821 |
| Instrument Type | Portable |
| Function Type | Multifunctional |
| Moisture Range | 3–35% (w/w) |
| Net Weight | 1 kg |
| Power Supply | DC 6 V (4 × AA alkaline batteries) |
| Measurement Time | < 5 s |
| Accuracy | ±0.5% (w/w) |
| Temperature Compensation | Automatic |
| Calibration Method | Floating 4-point calibration |
| Pre-programmed Crops | 20 common varieties |
| Operating Ambient Temperature | 0–40 °C |
| Auto Power-off | After 3 minutes of inactivity |
| Bulk Density Conversion | Integrated sampling device for wheat bulk density calculation |
| Brand | SENBE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | SEN-ABR50 |
| Instrument Type | Portable |
| Measurement Target | Solid Surfaces |
| Detector Technology | Plastic Scintillation Detector (Alpha/Beta/Gamma Discriminative) |
| Energy Response | Alpha (≥3 MeV), Beta (≥150 keV), Gamma (≥50 keV) |
| Display | Backlit LCD |
| Alarm | Adjustable Threshold with Real-Time Background Compensation |
| Power Supply | Rechargeable Li-ion Battery (≥12 h continuous operation) |
| Compliance | Meets IEC 60846-1:2014 and GB/T 10257–2022 for portable radiation contamination monitors |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SEN580 |
| Pricing | Available Upon Request |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SEN582 |
| Light Source | Simulated D65 Illuminant |
| Color Space | CIE L*a*b* |
| Bran Speck Content | Ratio of bran speck area to total sample surface area (%) |
| Whiteness | Blue-light Whiteness (Wb) |
| Display | Large LCD Touchscreen |
| Whiteness Resolution | ≤0.1 |
| Bran Speck Repeatability | Relative difference between duplicate measurements < 10% of arithmetic mean |
| Colorimetric Repeatability | ΔE*ab ≤ 0.5 |
| Preheat Time | 30 min |
| Power Supply | 220 V ±10%, 50 Hz |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH |
| Compliance | GB/T 27628–2011, Verified by National Grain Quality Inspection Center |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SEN785 |
| Instrument Type | Stimulated Raman Scattering (SRS) Microscope |
| Excitation Wavelength | 785 nm |
| Spectral Range | 200–3000 cm⁻¹ |
| Spectral Resolution | ≤8 cm⁻¹ |
| Spectral Shift Accuracy | ≤1 cm⁻¹ |
| Spectral Shift Repeatability | ≤1 cm⁻¹ |
| Detection Limit | 0.1% ethanol in N₂ |
| Dynamic Range | ≥33,000:1 |
| Detector SNR | ≥1000:1 |
| Detector | TEC-cooled back-illuminated CCD array (1024 × 58 pixels) |
| Microscope | Upright infinity-corrected plan achromat objectives (10×, 20×, 50× |
| Objective Turret | ≥4-position manual turret |
| Camera | ≥9 MP monochrome CCD |
| Stage | Mechanical XY stage (175 × 145 mm, 76 × 42 mm travel) |
| Software | Integrated spectral acquisition, multivariate analysis (PCA, PLS, CNN), HQI matching, AirPLS baseline correction, S-G/Whittaker/EMD denoising, 2D spectral mapping, and user-defined microplastic spectral library management |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SEN806C |
| Instrument Category | Manual Water Sampler |
| Instrument Type | Portable Water Sampler |
| Brand | Senbe |
|---|---|
| Model | SEN905 |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Localization | Domestic (China) |
| Network Support | China Mobile / China Telecom / China Unicom 2G/3G/4G LTE |
| GNSS Modes | DGNSS (<0.5 m), RTK (5 cm + 1 ppm) |
| Differential Formats | RTCM 3.0, RTCM 3.2 (vs. legacy RTD) |
| Display | 8-inch electromagnetic resonance touchscreen (U-Pen compatible) |
| Interface | USB Type-C (10,000-cycle durability) |
| Battery | Removable 8400 mAh Li-polymer |
| Operating System | Android 6.0.1 |
| Charging | Qualcomm Quick Charge 2.0 |
| Compliance | CE (EMC/LVD), RoHS, IP65-rated enclosure |
| Software Architecture | Field-deployable logging firmware with remote command ingestion and bidirectional telemetry |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | ST-85 |
| Instrument Type | Silicon Photocell-Based Illuminance Meter |
| Measurement Range | 0.1–199.9 × 10³ lx |
| Relative Indication Error | < ±4.0% |
| V(λ) Matching Error (f₁) | < 6.0% |
| Cosine Correction Error (f₂) | < 4.0% |
| Nonlinearity Error (f₃) | < ±1.0% |
| Range Switching Error (f₄) | < ±1.0% |
| Fatigue Error (f₅) | < −0.5% |
| Response Time | < 1 s |
| Operating Temperature | 0–40 °C |
| Operating Humidity | < 85% RH |
| Dimensions | 160 mm × 78 mm × 43 mm |
| Weight | 0.2 kg |
| Power Supply | 6F22 9 V alkaline battery (non-rechargeable) |
| Total Power Consumption | < 0.1 VA |
| Display | Backlit LCD |
| Range Selection | Manual/Automatic |
| Output Interface | USB digital output with redundant power capability |
| Additional Functions | Data hold, low-battery indicator, auto power-off delay, tactile key operation with audible beep feedback |
| Brand | Senbe |
|---|---|
| Model | T300S |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Detector | Si-Pin Semiconductor |
| Measurable Elements | S (16) to U (92) |
| X-ray Tube Voltage | 0–50 kV (intelligent programmable HV system) |
| Collimator | Standard Φ0.5 mm |
| Optical Magnification | 30× (industrial CCD camera) |
| Energy Resolution | ≤129 eV ±5 eV |
| Analysis Layers | Up to 5 simultaneous layers |
| Analyzable Elements per Measurement | Up to 24 |
| Algorithm | Fundamental Parameters (FP) method |
| Signal Processing | Digital Multi-Channel Analyzer (MCA) technology |
| Chamber Dimensions | 268 × 307 × 97 mm |
| Overall Dimensions | 414 × 416 × 362 mm |
| Safety Systems | Multi-dimensional thermal dissipation + dual interlock radiation shielding + real-time hardware status monitoring |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | UCA1000 |
| Instrument Type | Algal Monitoring and Control System |
| Compliance | HJ 915-2017, GB 3838-2002, GB/T 12519-2010 |
| Brand | Senbe |
|---|---|
| Model | VWH-1000 |
| Chamber Volume | (1.00 ± 0.02) m³ |
| Temperature Range | 15–40 °C (up to 250 °C for thermal desorption) |
| Temp. Control Accuracy | ±0.5 °C |
| RH Range | 30–80 %RH |
| RH Control Accuracy | ±3 %RH |
| Air Exchange Rate | 0.2–2.0 m³/h (0.2–2.0 air changes/h) |
| Flow Rate Accuracy | ±1 % |
| Horizontal Air Velocity | 0.1–0.3 m/s (precision ≤ 0.05 m/s) |
| Static Leakage Rate | ≤1×10⁻³ m³/min at 1 kPa differential pressure |
| Formaldehyde Background | <0.006 mg/m³ |
| TVOC Background | <0.05 mg/m³ |
| Individual VOC Background | <0.005 mg/m³ |
| Remote Control | PC & mobile web interface |
| Power Consumption | 1.5 kW (operational), 3.0 kW (rated) |
| Dimensions (W×H×D) | 1170 × 1660 × 2100 mm |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | YQ3000-E |
| Instrument Type | Flue Gas Dioxin Sampler |
| Sample Medium | Flue Gas |
| Flow Accuracy | ±5% |
| Sampling Flow Rate | 1.5 L/min |
| Flue Gas Velocity Range | Up to 4 m/s |
| Moisture Content Tolerance | Up to 60% (v/v) |
| Brand | Senbe |
|---|---|
| Origin | USA |
| Manufacturer | Original Equipment Manufacturer (OEM) |
| Product Type | Imported Instrument |
| Model | 9565-X |
| Pricing | Available Upon Request |