Shodex
Filter
Showing all 4 results
| Brand | Shodex |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RI-201 |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | HPLC |
| Refractive Index Range | 1.00–1.75 |
| Detection Range | 0.125–256 µRIU |
| Drift | ≤0.1 µRIU/h |
| Noise | ≤1 nRIU |
| Linear Range | ≥300 µRIU |
| Flow Rate (Typical) | 0.2–3.0 mL/min |
| Max Flow Rate (Water) | 10 mL/min |
| Cell Volume | 8 µL |
| Dead Volume (IN→Cell) | ~80 µL |
| Dead Volume (Cell→OUT) | ~600 µL |
| Total Dead Volume | ~690 µL |
| Temperature Control Range | 30–55 °C (1 °C increments), with dual-stage thermal regulation |
| Response Time Settings | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 s |
| Auto-Zero Function | Full-range, fully automatic |
| Offset Adjustment Range | ±5 µRIU |
| Offset Resolution | 25 nRIU |
| Analog Output | DC 0–1 V (4 mV/µRIU or 16 mV/µRIU selectable) |
| Recorder Output | 0–10 mV/FS |
| Communication Interface | USB |
| Wetted Materials | SUS316 Stainless Steel, PTFE, Quartz Glass |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz, 150 VA |
| Dimensions & Weight | 260 × 400 × 150 mm (W×D×H), ~12 kg |
| Brand | Shodex |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RI-201H |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Refractive Index Range | 1.00–1.75 |
| Detection Range | 0.25–512 μRIU |
| Drift | ≤0.2 μRIU/h (deionized water, 1 mL/min, purge off) |
| Linearity | ≥600 μRIU |
| Noise | ≤2.5 nRIU (deionized water, 1.5 s response) |
| Response Time Settings | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 s |
| Auto-Zero | Full-range automatic zeroing |
| Offset Adjustment Range | ±10 μRIU |
| Offset Resolution | 50 nRIU |
| Cell Volume | 8 µL |
| Flow Rate Range | 0.2–3.0 mL/min (typical), up to 10 mL/min (water) |
| Max Backpressure | 50 kPa |
| Internal Dead Volume | IN→Cell ≈60 µL |
| Temperature Control | OFF, 30–55 °C (1 °C increments), 77 °C thermal cutoff |
| Interface | USB |
| Wetted Materials | SS316, PTFE, fused silica |
| Power | AC 100–240 V ±10%, 50/60 Hz, 150 VA |
| Dimensions & Weight | 260 × 400 × 150 mm (W×D×H), ~12 kg |
| Brand | Shodex |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RI-201H |
| Detection Principle | Differential Refractive Index (dRI) |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Detector Type | Refractometer-Based Chromatographic Detector |
| Flow Cell Design | Dual-Chamber |
| Refractive Index Range | 1.00–1.75 |
| Detection Sensitivity Range | 0.25–512 µRIU |
| Baseline Drift | ≤0.2 µRIU/h (deionized water, 1 mL/min, purge off) |
| Linearity | ≥600 µRIU |
| Noise Level | ≤2.5 nRIU (deionized water, 1.5 s response time) |
| Response Time Settings | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 s |
| Auto-Zero Function | Full-range automatic zeroing |
| Offset Adjustment Range | ±10 µRIU |
| Offset Resolution | 50 nRIU |
| Analog Output | DC 0–1 V (2 mV/µRIU or 8 mV/µRIU selectable) |
| Flow Cell Volume | 8 µL |
| Recommended Flow Rate | 0.2–3.0 mL/min |
| Maximum Flow Rate | 10 mL/min (water) |
| Maximum Backpressure | 50 kPa |
| Dead Volume | IN→Cell ≈ 60 µL |
| Recorder Output | 0–10 mV full scale |
| External I/O Signals | READY, LEAK, ERROR (ROM/RAM/Parameter/Home Position/Overheat/Optical Balance/Intensity) |
| Temperature Control | Off, 30–55 °C (1 °C increments), thermal fuse at 77 °C |
| Interface | USB |
| Wetted Materials | ASTM F899 stainless steel 316, PTFE, fused silica quartz |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz, max. 150 VA |
| Dimensions & Weight | 260 × 400 × 150 mm (W×D×H), approx. 12 kg |
| Brand | Shodex |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | RI-501, RI-502, RI-504 |
| Detection Principle | Differential Refractive Index (dRI) |
| Light Source | Deuterium Lamp |
| Temperature Control | Dual-zone thermostatic control (30–55 °C) |
| Flow Rate Range | 0.2–3.0 mL/min (RI-501/RI-504), 1–50 mL/min (RI-502) |
| Cell Volume | 8 μL (RI-501/RI-502), 2.5 μL (RI-504) |
| Noise Level | ≤2.5 nRIU (RI-501), ≤25 nRIU (RI-502), ≤5 nRIU (RI-504) |
| Drift | ≤0.2 μRIU/h (RI-501/RI-504), ≤2 μRIU/h (RI-502) |
| Response Time | Adjustable from 0.1 to 6 s |
| Output Interface | LAN, Analog (0–1 V, 0–10 mV/FS), Digital I/O (READY/LEAK/ERROR) |
| Wetted Materials | SUS316 Stainless Steel, PTFE, Fused Silica |
| Compliance | CE Marked, RoHS Compliant |