Solar Light
Filter
Showing all 10 results
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | 16S Series (150W–300W UV) |
| Spectral Range | 290–400 nm (UV-A/UV-B selectable) |
| Beam Uniformity (center) | >90% |
| Compliance | ASTM G154, ASTM G155, IEC 61215, ISO 4892-3 |
| Output Orientation | Vertical-down / Vertical-up / Horizontal |
| Optional Spectral Configurations | UVA-only, UVB-only, UVA+UVB, AM0 (250–2500 nm), AM1.5G (250–2500 nm), Visible-only |
| Optional Accessories | Motorized shutter with remote control, calibrated neutral density attenuation screens, spectral verification report, custom collimation optics |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | 8-5103 |
| Surface Roughness (Ra) | 5 µm (ISO-compliant) |
| Package Quantity | 200 pcs/box |
| Material | Polymethyl Methacrylate (PMMA) |
| Form | Flat Optical Diffuser Plate |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | 8-5105 |
| Dimensions | 50.3 mm × 50.3 mm |
| Surface Roughness (Ra) | 5 µm |
| Surface Roughness (Sa) | 6 µm |
| Compliance | ISO 25178-2 |
| Packaging | 200 pcs per box |
| Category | Spectroscopy Accessory / Optical Diffuser Plate |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | LS1000 1000W UV |
| Spectral Range | 290–400 nm |
| Output Configurations | Circular or Square Beam (2", 4", 6" / 5 cm, 10 cm, 15 cm) |
| Uniformity | ≥98% over usable area |
| Collimated Working Distance | 35.5 cm |
| Compliance | ASTM G154, ASTM G155, IEC 61215, ISO 4892-3, CE |
| Light Source | 1000W Xenon Arc Lamp |
| Power Supply | High-Efficiency Switching PSU with Adjustable Lamp Power |
| Optional Filters | UVA-only, UVB-only, Visible-only, Neutral Density Attenuation Screens |
| Beam Orientation | Vertical Downward, Vertical Upward, or Horizontal |
| Long-Term Stability | <±1% drift per 100 hours |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | Microtops II |
| Optical Channels | 340, 380, 440, 500, 675, 870, 936, 1020 nm (user-selectable 5-channel configuration) |
| Spectral Bandwidth (FWHM) | 2–10 nm depending on channel |
| Stray Light Rejection | ≤1×10⁻⁶ (λ < 650 nm), ≤1×10⁻⁵ (λ < 1.2 µm) |
| Dynamic Range | >300,000 |
| Radiometric Resolution | 0.1 W/m² |
| Field of View | 2.5° |
| Accuracy | ±1–2% |
| Nonlinearity | ≤0.002% FS |
| Operating Temperature | 0–50 °C, no precipitation |
| Power | 4×AA alkaline batteries |
| Weight | 600 g |
| Dimensions | 10 × 20 × 4.3 cm |
| Interface | RS-232C |
| Data Storage | Non-volatile memory with timestamp, GPS coordinates (optional), solar zenith angle, altitude, pressure, temperature |
| Software | MICROTOPS Organizer (Windows-based data retrieval and archiving) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | Mono602® |
| Compliance | ISO 23698:2024, ISO 24442, BS EN 62471:2008 |
| Spectral Range | 290–400 nm |
| Measurement Time per Sample | 3–4 s |
| Operating Temperature | 15–35 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Power Supply | 110–240 VAC, 50/60 Hz, max. 7 A |
| Dimensions (H×W×L) | 52.4 × 40.6 × 50.8 cm |
| Weight | 29 kg |
| Fiber Optic Probe | Bifurcated bundle with integrated contact probe, 1.8 m length |
| UV Exposure Level | Below ACGIH TLV® and occupational exposure limits |
| Footswitch & Keyboard Control | Included |
| Software | HDRSplus™ v5.x (Windows-based, FDA 21 CFR Part 11 ready) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2106 |
| Detection Principle | Broadband Non-Weighted UVB (280–320 nm) |
| Spectral Response | Flat, Unfiltered Silicon Photodiode with UVB-optimized optical filter |
| Angular Response | Lambertian (Cosine-corrected, ±5% up to 60° incidence) |
| Measurement Range | 0.001–200 mW/cm² (0.01–2000 W/m²) |
| Resolution | 0.001 mW/cm² / 0.01 W/m² |
| Operating Temperature | 0–50 °C (32–120 °F), non-condensing |
| Temperature Coefficient | ±1 %/°C (for solar UVB irradiance) |
| Cable | Retractable coaxial, 0.3–1.5 m |
| Dimensions | Ø40.6 mm × H45.8 mm |
| Weight | 200 g |
| Calibration | NIST-traceable, factory-calibrated for UVB irradiance (mW/cm² and W/m²) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | Poly602® |
| Compliance | ISO 23698:2024, ISO 24442, BS EN 62471:2008, ACGIH UV Exposure Guidelines |
| Spectral Range | 320–400 nm |
| Operating Temperature | 15–35 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Power Supply | 110–240 VAC, 50/60 Hz, max 7 A |
| Interface | USB |
| Dimensions (H×W×L) | 26.2 × 40.6 × 40.6 cm |
| Clear Rear Clearance Required | 8 cm |
| Weight | 15.4 kg |
| Fiber Optic Probe | Bifurcated bundle with integrated contact probe, 1.8 m length |
| Measurement Time per Sample | ~3–4 s |
| Throughput | 10 subjects × 8 products = ~8 hours |
| UV Exposure Level | Below occupational exposure limits (ACGIH/IEC 62471) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | SPF-290AS |
| Wavelength Range | 290–400 nm |
| Scan Resolution Options | 1 nm, 2 nm, or 5 nm |
| Compliance | ISO 23698:2024, ISO 23675:2024, ISO 24443, FDA Guidance, COLIPA, Boots Star Rating Methodology |
| Sample Types | Lotions, creams, sprays, gels, powders, emulsions, textiles |
| Data Output | Monochromatic Protection Factor (MPF), SPF, UV transmittance spectra |
| Software Features | Pre-loaded erythemal action spectrum & solar irradiance reference data (CIE 1987 / ISO 17166), user-modifiable weighting functions, audit-trail-enabled calculation logs |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | SPF601 |
| Spectral Range | 290–400 nm (UVA + UVB) |
| Output Configuration | Six independent 8-mm square irradiation ports |
| Irradiance Control | Individual manual knob per port + optional XPS-300 programmable power supply |
| Maximum Irradiance | Up to 4 MED/min per port |
| Solar Simulation Fidelity | >90% spectral match to CIE Reference Solar Spectrum (ISO 17166:2019/Erythema Action Spectrum) |
| Mechanical Positioning | Integrated precision locking gooseneck arm with UV-stable optical coupling |