Solartron Analytical
Filter
Showing all 16 results
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1250 |
| Frequency Range | 10 µHz – 65 kHz |
| Signal Amplitude Range | 10 mV – 10.23 V (AC), up to 300 V (analysis input range) |
| Waveform Options | Sine, Square, Triangle |
| Amplitude Resolution | 1/1023 |
| Compliance | ASTM E2928, IEC 61000-4-30 (power quality), ISO/IEC 17025-accredited calibration support available |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1260A |
| Channel Count | Single-Channel Workstation |
| Current Range | 200 nA – 2 A |
| Current Accuracy | ±0.2% of reading + ±1% of full scale |
| Potential Accuracy | ±0.2% of reading + ±10 mV |
| Potentiostatic Range | ±14.5 V (when coupled with 1287) / ±40.95 V (1260A standalone) |
| AC Impedance Frequency Range | 10 µHz – 32 MHz |
| Voltage/Current Resolution | 1 µV / 1 pA |
| Frequency Resolution | 0.015 ppm |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1 dB |
| Electrode Configurations | 2-, 3-, and 4-terminal |
| Active Shielding | Yes |
| Floating Measurement Capability | Yes |
| Software | CorrWare & ZPlot v3.x |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1260A |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Current Range | ±60 mA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±40.95 V |
| AC Impedance Frequency Range | 10 µHz – 32 MHz |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1% |
| Frequency Resolution | 0.015 ppm |
| Core Technology | Single-Sine Correlation Method |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1455 / 1451 |
| Frequency Range | 10 Hz – 1 MHz (1455), 10 Hz – 100 kHz (1451) |
| Frequency Resolution | 1 / 65,000,000 |
| DAC Sampling Rate | 40 MHz |
| Accuracy | ±0.1% magnitude, ±0.1° phase |
| Phase Resolution | 0.01° |
| RMS Signal Amplitude | 3 V – 50 V |
| Waveform Options | Single-sine, multi-sine (FFT-based) |
| Input/Output Interface | Ethernet per module |
| Expandable Channels | 1–8 independent FRA units per system |
| Auxiliary Voltage Analyzer Ports | 4 (requires 14702A/14703A option with 1470E) |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model Series | 1470E |
| Current Range | ±4 A |
| Current Accuracy | ±0.1% of full scale |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | −3 V to +10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1470E Series |
| Channel Count | Up to 8 independent channels per unit |
| Current Range | ±4 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Control Interface | Ethernet |
| Compliance | ASTM G102, ISO 17475, IEC 62660-2, USP <1058>, FDA 21 CFR Part 11 (software audit trail enabled) |
| Safety | Per-channel hardware-based voltage/current limit enforcement, fast-acting termination logic (<100 µs response) |
| Brand | Solartron Analytical |
|---|---|
| Origin | USA |
| Model | 9300R-SA |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Channel Count | 1–4 Configurable Channels |
| DC Current Range | ±200 A (300 A Pulse), Up to ±800 A with 4-Channel Parallel Operation |
| DC Current Accuracy | ±0.02 % of Reading |
| Potential Accuracy | ±30 µV |
| Potentiostatic Range | +300 mV to +10 V |
| EIS Frequency Range | 1 mHz to 10 kHz |
| Voltage Resolution | 20 µV (24-bit ADC) |
| Current Resolution | 2 µA (24-bit ADC) |
| DC Sampling Rate | 1 kS/s |
| Auxiliary Voltage Divider Inputs | 2 (for DC/EIS) |
| Temperature Monitoring | Optional External 16-Channel Synchronized Acquisition |
| Power Supply | 3-Phase 380 V, 5.5–11 kW |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Energylab XM |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | 0.1% + 0.05% + 30 fA |
| Potential Accuracy | 0.1% + 0.05% + 100 µV |
| Potentiostatic Range | ±8 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Impedance Measurement Limit | <100 µΩ (with external amplifier support up to 100 A) |
| Sampling Rate | Up to 1 MS/s (DC), 40 MS/s (FRA) |
| Auxiliary Differential Inputs | 4-channel synchronized with RE |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Energylab XM |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±8 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Low-Impedance Measurement Capability | Down to 10 µΩ |
| Current Resolution | 100 aA |
| Voltage Resolution | 1 µV |
| Sampling Rate | Up to 1 MS/s (DC), 40 MS/s (FRA) |
| Auxiliary Differential Inputs | 4-channel |
| Compliance | ASTM G5, G59, G102 |
| Brand | Solartron Analytical |
|---|---|
| Origin | UK |
| Model | HV 9250 |
| Channel Configuration | Multi-channel (1 or 2 main channels + up to 5 auxiliary voltage divider channels) |
| Current Range | ±125 A to ±250 A |
| Current Accuracy | ±0.1% |
| Potential Accuracy | ±0.1% |
| Potentiostatic Range | ±60 V, ±120 V, ±240 V |
| EIS Frequency Range | 1 mHz – 10 kHz |
| Maximum Power per Main Channel | 10 kW |
| Data Acquisition Rate | 10 kS/s |
| ADC Resolution | 24-bit (120 µV main channel, 20 µV auxiliary) |
| Input Impedance | 10 MΩ (all voltage inputs) |
| Temperature Inputs | 6 thermistor channels (1 per main + 5 auxiliary), 16 thermocouple channels via external VTI1401 DAQ |
| Digital I/O | 1 input, 1 output (trigger/control) |
| Software Platform | Aspire™ electrochemical control and analysis suite |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Modulab XM DSSC |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±100 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Compliance | NIST-traceable light source calibration |
| Software Platform | ModuLab XM Control & Analysis Suite |
| Upgrade Path | Compatible with legacy Modulab and Modulab XM hardware modules |
| Brand | Solartron Analytical |
|---|---|
| Origin | UK |
| Model | Modulab XM ECS |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±100 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM MTS (1296A + 1294A) |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | ±0.2% of setting |
| Potentiostatic Range | ±100 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Impedance Measurement Range | 100 Ω – 100 TΩ (12 decades) |
| Dielectric Loss Tangent Resolution | tan δ < 10⁻⁴ |
| Max DC Bias Voltage | 1000 V (with external high-voltage source or amplifier) |
| Compliance | IEC 601 for biomedical applications (1294A), ASTM D257, ISO 3001, IEEE Std 930 |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM PhotoChem IPCE |
| Current Range | ±300 mA |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±8 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Compliance | NIST-traceable light source calibration included |
| Software | ModuLab XM Suite with dedicated PhotoElectroChemical (PEC) experiment modules |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM PhotoChem IPCE |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±8 V to ±100 V (high-voltage option) |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Light Source Calibration | NIST-traceable |
| Software Platform | ModuLab XM Suite with PhotoElectroChem module |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM PhotoEchem IPCE |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±100 V |
| EIS Frequency Range | 10 µHz – 1 MHz |