SOTAX
Filter
Showing all 8 results
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | AT Xtend |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 6–8 |
| Temperature Range | 30–40 °C |
| Rotational Speed Accuracy | ±1 rpm |
| Regulatory Compliance | 21 CFR Part 11–compliant software control |
| Applicable USP Methods | USP <711> (Apparatus 1, 2, 5, 6) |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | AT50 |
| Instrument Type | Oscillating Hardness Tester |
| Compliance | FDA 21 CFR Part 11 Ready |
| Sample Throughput | Up to 10 distinct products per run |
| Measurement Parameters | Weight, Thickness, Width/Diameter/Length, Hardness |
| Alignment Technology | AutoAlign™ and SmartAlign™ |
| Feeding System | Multi-compartment magazine feeder (10 slots) |
| Weighing Platform | Vibration-damped, auto-centering |
| Rejection Mechanism | Real-time fragment & doublet detection |
| Software Integration | q-doc® LIMS-ready data management |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | CE 7smart |
| Instrument Type | Online Dissolution Tester |
| Number of Dissolution Cells | 7 |
| Temperature Range | 20–45 °C (deviation < ±0.1 °C) |
| Temperature Accuracy | ±0.1 °C |
| Water Bath Temperature Resolution | ±0.2 °C |
| Water Bath Volume | 8 L |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | DT2 |
| Number of Disintegration Baskets | 2 |
| Bath Volume | 5.5 L |
| Temperature Range | 20–60 °C |
| Stroke Frequency | 30 ± 1 cycles/min |
| Detection Principle | Conductivity-based tablet contact sensing with USP-compliant stainless steel mesh |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | PF1 |
| Measurable Parameter | Angle of Repose |
| Compliance | USP <1174>, Ph. Eur. 2.9.36 |
| Test Principle | Orifice Flow (Funnel-Flow) Method |
| Weight | 20 kg |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | ST50 |
| Compliance | 21 CFR Part 11, USP <1217>, EP 2.9.8 |
| Measurement Range | 0–300 N (adjustable) |
| Force Resolution | 0.1 N |
| Positioning Accuracy | ±0.05 mm |
| Sample Handling | Up to 5 physical parameters per cycle (hardness, weight, thickness, diameter/length, width) |
| Data Output | CSV, PDF, XML |
| Safety | ESD-Safe Enclosure |
| Interface | 7-inch capacitive touchscreen with graphical workflow navigation |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | TD1 |
| Instrument Type | Bulk Density Tester |
| Application | Solid Pharmaceutical Powders & Granules |
| Compliance | USP <616>, USP <617>, EP 2.9.34, ASTM D1464 |
| Tap Frequency | 300 ±2 taps/min (USP Method I), 250 ±2 taps/min (USP Method II / EP / ASTM) |
| Tap Height | 14 ±2 mm (USP I), 3 ±0.3 mm (USP II / EP / ASTM) |
| Cylinder Positions | 1 |
| Cylinder Volumes | 100 mL and 250 mL (interchangeable) |
| Display | 24×2 character LCD |
| Data Storage | 30 test results with timestamp, method ID, and calculated parameters |
| Output | GMP/GLP-compliant printout (via integrated thermal printer) |
| Design | Benchtop, single-cylinder, electromechanical tapping system with synchronized rotation and tapping motion |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | TPW |
| Application Scope | Solid Oral Dosage Forms, Granulation Intermediates, Semi-solids (e.g., Toothpaste, Lipstick) |
| Sample Throughput | 100–200 samples per run |
| Solvent Volume Range | 20–100 mL or 50–520 mL |
| Integrated Unit Functions | Automated Weighing, High-Shear Homogenization, Filtration, Dilution, Data Logging & Storage |
| Software | DoE-Enabled Method Development Suite with Cross-Site Transfer Capability |
| Regulatory Alignment | Designed for GLP/GMP environments |