Systech Illinois
Filter
Showing all 6 results
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7101 |
| Pricing | Available Upon Request |
| Measurement Range | 0.002–70 g/(m²·d) (unmasked) |
| Temperature Control Range | 10–40 °C (50–104 °F) |
| Relative Humidity Control Range | 20–90 % RH |
| Sample Area | 50 cm² (adapters available for smaller specimens) |
| Sensor Technology | High-sensitivity Coulometric P₂O₅ sensor |
| Compliance | ASTM F3299–18 |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8101e |
| Test Gas | O₂ |
| RH Control Range | 0–90% ±2% |
| Temperature Control Range | 10–40°C ±0.1°C |
| Sensor Type | eMetric™ Coulometric Sensor |
| Sample Types | Flexible Films & Rigid Packaging |
| Maximum Configurable Stations | 32 |
| Operating System | Windows®-based Platform |
| Sealing Method | Q-Seal™ Chamberless Seal |
| Compliance | ASTM F2622, ASTM D3985, ISO 15105-2, ISO 1186 |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8102 |
| Measurement Principle | Coulometric Sensor (Electrochemical Oxygen Detection) |
| Standards Compliance | ASTM D3985, ASTM F1307, ASTM F1927, DIN 53380-3, ISO 15105-2, JIS K 7126 |
| OTR Range | 0.05–432,000 cc/(m²·day) |
| Resolution | 0.01 cc/(m²·day) |
| Repeatability | ±0.015 cc/(m²·day) or ±1% |
| Test Chamber Temperature Range | 10–40 °C (±0.1 °C) |
| Film RH Control | 0–100% RH (dry to saturated via humidified sponge) |
| Package RH Control | Ambient or chamber-controlled |
| Sensor Technology | Long-life e-Metric® coulometric cell |
| Anti-Surge™ Protection | Yes |
| Gas Requirement | Ambient air only (no N₂/H₂ mix required) |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8107 |
| Measurement Principle | Coulometric Sensor (ASTM F1307) |
| Test Range | 0.00025–2000 cm³/(pkg·day) |
| Resolution | 0.00001 cm³/(pkg·day) |
| Repeatability | ±0.00001 cm³/(pkg·day) or ±2% |
| Sensor Technology | Long-life E-metric Coulometric Cell |
| Protection | Anti-Surge™ Over-O₂ Compensation |
| Gas Requirement | Ambient air only (no N₂/H₂ mix required) |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8700 |
| Measurement Range (Pack) | 0.00004–2000 cm³/pack/day |
| Measurement Range (Film) | 0.04–100,000 cm³/m²/day |
| Test Temperature | Ambient (with optional temperature-controlled chamber) |
| Relative Humidity Control | Dry to 100% RH (saturated) |
| Calibration Standards | NIST-traceable reference films and certified gases |
| Dimensions | 760 × 590 × 350 mm |
| Weight | 65 kg |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | Lyssy L80-6000 |
| WVTR Range | 0.03 – 10,000 g/m²/day (standard) |
| Test Temperature Range | 5 – 50°C |
| Relative Humidity Control Range | 5 – 60% RH |
| Ambient Humidity Tolerance | 10 – 90% RH (non-condensing) |
| Dimensions | 400 × 400 × 350 mm |
| Weight | 24 kg |
| Software | Permetrace™ |