TAITEC
Filter
Showing 31–36 of 36 results
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VC-96W |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Room Temperature +5°C to +65°C |
| Temperature Control Accuracy | ±0.1°C |
| Maximum Sample Capacity | 200 mL |
| Rotational Speed | 100–2600 rpm (up to 800 × g with 96S swing rotor) |
| Timer Range | 1–99 min |
| Chamber Material | SUS316 stainless steel with PTFE coating |
| Lid Material | PVC |
| Vacuum Gauge | 0 to –0.1 MPa (Bourdon tube) |
| Vacuum Release | Manual |
| Heating Method | Far-infrared heater |
| Safety Features | Lid interlock power cutoff, independent overheat protection sensor, motor circuit breaker, real-time anomaly display (power failure, rotation error, lid open) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VIX-100 |
| Timer Range | 15 min |
| Oscillation Speed | up to 2000 rpm |
| Platform Configuration | Single or Dual Shaking Plates |
| Operating Temperature | Ambient |
| Applicable Vessels | 20 mL glass vials (100 units), capped tubes up to 180 mm in length |
| Platform Dimensions | 325 × 325 mm |
| Power Supply | AC 100 V, 2 A |
| Weight | ~32 kg |
| Compliance | Designed for GLP-compliant sample preparation workflows |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VP-050N / VP-300N |
| Output Power | 50 W (VP-050N), 300 W (VP-300N) |
| Frequency Range | 19.5–20.5 kHz (VP-050N), 19–21 kHz (VP-300N) |
| Transducer Interface | Integrated horn-type piezoelectric converter with auto-tuning |
| Control | Digital LCD interface with real-time % output, current, temperature (*optional sensor), timer (1 s–120 min), and pulse mode (ON/OFF: 0.1–60 s) |
| Probe Options | Φ2 mm, Φ3 mm, Φ6 mm stepped microprobes (VP-050N) |
| Dimensions (W×D×H) | 122×288×283 mm (VP-050N), 143×360×283 mm (VP-300N) |
| Weight | 4.5 kg (VP-050N), 6.7 kg (VP-300N) |
| Power Supply | AC 100 V, 1 A (VP-050N), AC 100 V, 5 A (VP-300N) |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Wave-PR / Wave-SI / Wave-SI Slim |
| Oscillation Frequency | 5–50 rpm (Wave-PR), 10–60 rpm (Wave-SI & Wave-SI Slim) |
| Oscillation Angle | 2°–6° (adjustable, Wave-PR), 2°–10° (adjustable, Wave-SI), 6° (fixed, Wave-SI Slim) |
| Operating Temperature Range | 0 °C to +50 °C |
| Platform Quantity | 1 |
| Platform Dimensions | 300 × 200 mm (Wave-PR), 180 × 120 mm (Wave-SI), 180 × 130 mm (Wave-SI Slim) |
| Max Load Capacity | ~2 kg (excluding platform and fixtures) |
| Power Supply | AC 100 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-01 |
| Disruption Principle | Horizontal umbrella-shaped oscillation |
| Speed Range | 2,500–4,600 rpm (6 preset steps) |
| Sample Volume | 2 mL |
| Sample Capacity | 1 tube per run |
| Compatible Beads | Glass, zirconia, stainless steel beads (φ0.15–6 mm), metal mortars |
| Operating Temperature | +5 to +35 °C |
| Vibration Frequency | 40–78 Hz |
| Timer Range | 5–60 s (6 presets) |
| Safety Features | Lid interlock stop, overload current protection |
| Dimensions | 172 × 280 × 160 mm (W × D × H) |
| Weight | ~5 kg |
| Power Supply | AC 100 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-12 |
| Instrument Type | Bead Mill Cell Disruptor |
| Operating Frequency | 53 Hz |
| Sample Capacity | 12 × 5.0 mL tubes |
| Throughput | 12 samples per run |
| Speed Range | 1,800–3,200 rpm (8-step digital adjustment) |
| Timer | 1–300 s (1-s increment, memory for 2 speed/time presets) |
| Safety Features | Lid-interlock shutdown, overload current protection |
| Dimensions | 310 × 400 × 200 mm (W × D × H) |
| Weight | ~15 kg |
| Power Supply | AC 100 V, 4 A |
| Ambient Operating Range | +5 °C to +35 °C |
| Tube Compatibility | Standard threaded 1.5/2.0 mL and 5.0 mL microtubes (e.g., Watson 1392-200, 2332-105) |
| Bead Compatibility | Stainless steel (SUS), zirconia, glass beads |