TAMASAKI
Filter
Showing all 6 results
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Model | FY-18L |
| Light Source | 18 W High-Power White LED |
| Illuminance | ~34,000 lux at 45 cm (with clear filter) |
| Adjustable Brightness | Continuous DC dimming (0–100%) |
| Optical Output | Dual-filter system (clear and diffuser), optional Daiglo green bandpass filter (transmission peak ~525 nm, cutoff <500 nm & >600 nm) |
| Cooling | Fanless active heat sink |
| Power Input | AC 100–240 V, 47–63 Hz |
| Output | DC 24 V / 1.67 A |
| Power Consumption | 2.8–22.6 W |
| LED Lifetime | ≈50,000 h (L70) |
| Dimensions (Base) | W180 × D120 × H50 mm |
| (Light Head) | Ø68 × D86 mm |
| (Max Extended Height) | 638 mm |
| Weight | 3.4 kg (lamp only, excluding adapter) |
| Photodetector Type | Silicon photodiode (integrated illuminance reference path) |
| Compliance | CE-marked per EN 61326-1 (EMC), EN 62471 (Photobiological Safety), RoHS 2015/863/EU |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JIS-Z2502 |
| Compliance | JIS Z 2502 (2018) for Metal Powder Flowability Testing |
| Power Supply | 100 V AC, 10 VA, 50/60 Hz |
| Timer Accuracy | ±0.005% + 20 ms |
| Timer Display Resolution | 0.01 s |
| Approximate Weight | 4 kg |
| Application Domain | Printed Electronics, Semiconductor Component Fabrication, Additive Manufacturing Feedstock QA |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DPC-201N12 |
| Drive Method | Manual |
| Measurement Range | ±200.0 Pa |
| Display Resolution | 0.1 Pa |
| Accuracy | ±0.1% FS ±1 digit |
| Temperature Drift | ±0.12% FS/°C |
| Display Update Interval | 0.1 s |
| Analog Output | 1–5 V (fully scalable) |
| Warm-up Time | 10 min |
| Sensor Type | Silicon Diaphragm |
| Compatible Media | Non-corrosive and mildly corrosive gases |
| Overpressure Limit | 10 kPa |
| Static Pressure Range | 30 kPa |
| Operating Ambient Temperature | 0–45°C (40°C max with AC adapter) |
| Dimensions | 96 × 96 × 141 mm (W × H × D) |
| Weight | 0.9 kg (excl. AC adapter) |
| Pressure Port | Φ8 mm hose barb (convertible to PT1/4 internal thread) |
| Power Supply | DC 12 V ±10% via included AC adapter (AC 100 V input, 10 W consumption) |
| Standard Functions | Hi/Go/Lo contact outputs (AC 250 V, 2 A), contact hysteresis setting (0–20 digits), moving average time setting (0–20 s), analog output scaling, zero-hold external signal input (dry contact) |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HP-1000-T |
| Packing Material | Helipack No.2 (SUS316) |
| Theoretical Plates | 35 |
| Hold-up Volume | 30–50 mL |
| Max. Throughput | ~1.4 L/h (n-heptane) |
| Feed Capacity | 200–800 mL |
| Pressure Drop | ≤1.463 kPa |
| Distillation Column | Packed, φ22×1000 mm, Vacuum-Jacketed |
| Distillation Flask Options | 500 mL and 1 L |
| Heating Mantle | AC 100 V, 500 W / 300 V, 1000 W / 450 V |
| Reflux Ratio Timer | Sample Collection 0–999 s, Reflux Duration 0–999 s |
| Operating Pressure Range | Full vacuum to atmospheric |
| Temperature Range | Ambient to 300 °C |
| Power Supply | AC 100 V, 0.6 kVA |
| Dimensions | 650(W) × 450(D) × 2000(H) mm |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Manufacturer | DKK TOA Corporation |
| Model | TTT-710 |
| Application | Automated Electrode Handling & Multi-Sample Conditioning for Benchtop Conductivity/Resistivity Meters |
| Optional Accessories | Pure Water Spray Rinse, Chemical Rinse Module, Air Blow Dry, Front-Mounted Electrode Cleaning & Storage Compartment, External Circulating Thermostatic Bath Integration (for ISO/ASTM-compliant temperature-controlled conductivity measurements) |
| Security | User Access Control, Audit-Trail-Ready Data Integrity Protection (aligned with GLP/GMP documentation requirements) |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Model | SP-255-FU20kN |
| Measurement Principle | Hydraulic transduction with strain-gauge-based pressure sensing |
| Measurement Range | 2.0 kN to 20.0 kN |
| Resolution | 0.1 kN (10 kgf) |
| Accuracy | ±1% of full scale (FS) |
| Operating Temperature | 0 °C to 40 °C |
| Power Supply | 2 × AA alkaline batteries |
| Battery Life | ≥8 hours (continuous operation) |
| Auto-zero Function | Yes |
| Peak Hold & Data Hold | Yes |
| Auto-power-off | After 5 minutes of inactivity |
| Display Update Rate | 2 Hz (refresh every 0.5 s, with 64 samples/sec internal acquisition) |
| Sensor Housing | Integrated hydraulic insulation structure |
| Weight | 610 g (sensor head + 1.5 m cable), 430 g (main unit with batteries) |