Tekmar
Filter
Showing all 6 results
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Model | AQUATek LVA |
| Sample Tray Capacity | 84 positions |
| Vial Size | 40 mL |
| Trap Temperature Range | Ambient to 350 °C |
| Sample Handling | Fully enclosed, refrigerated processing |
| Injection Loop Material | PEEK |
| Loop Volume Options | 5 mL, 10 mL, 20 mL, 25 mL |
| Internal Standard Storage | UV-protected amber vials with PEEK caps |
| System Cleaning | High-temperature water rinse of liquid pathways |
| Software | TekLink™ (integrated control for autosampler and purge-and-trap concentrator) |
| Regulatory Compliance | HJ 639–2012, HJ 686–2014, HJ 788–2016, HJ 806–2016, HJ 866–2017, HJ 893–2017, HJ 896–2017, GB/T 5750.8–2023 |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water & Soil Compatible |
| Sample Tray Capacity | 84 positions |
| Trap Temperature Range | Ambient to 350 °C |
| Brand | Tekmar |
|---|---|
| Origin | USA |
| Model | Fusion |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV Light + Sodium Persulfate |
| Measurement Range | 0.2 ppb C to 4,000 ppm C |
| Accuracy | ±1% |
| Detection Limit | 0.2 ppb C |
| Precision (RSD) | ≤1% |
| Regulatory Compliance | EPA Methods 415.1–415.3, 9060A |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Detection Limit | 50 ppb |
| Linear Range | 0–20,000 ppm (with 0.5 mL injection volume) |
| Compliance Standards | EPA 415.1/415.3/9060A, ISO 8245, EN 1484, USP <643>, ASTM D2579, SM 5310B, HJ 501-2009, GB/T 32116-2015, AOAC 973.47 |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water & Soil Compatible |
| Sample Tray Capacity | 84 positions |
| Trap Temperature Range | Ambient to 350 °C |
| Purge Volumes | 5 mL and 25 mL selectable |
| Flow Control | Mass Flow Controller (MFC) with programmable pressure/flow profiles |
| Cleaning | High-Temperature Water Rinse |
| Optional Features | Foam Monitoring/Elimination, Multi-Application Traps |
| Regulatory Compliance | ASTM D6866, EPA Methods 502.2, 524.2, 524.4, 624, 8260D, 8270E |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Detection Limit | 500 ppb |
| Quantification Range | 50 ppb – 30,000 ppm |
| Compliance | HJ 501–2009, GB/T 32116–2015, EPA Methods 415.1, 415.3, and 9060A, Standard Methods 5310B, ISO 8245, EN 1484, USP <643>, ASTM D2579, AOAC 973.47 |