Timepower
Filter
Showing all 17 results
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP737 |
| Pricing | Upon Request |
| Measurement Range | 0.0 °C to 1372 °C |
| Temperature Resolution | 0.1 °C (0.0–999.9 °C), 1 °C (>999.9 °C) |
| Temperature Accuracy | ±0.2% of reading |
| Ambient Operating Temperature | ≤30 °C |
| Relative Humidity | 10–70% RH |
| Storage/Transport Temperature | −25 °C to +55 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | ≤2 kW |
| Dimensions (H×W×D) | 500 mm × 400 mm × 360 mm (main unit) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP791 |
| Pricing | Available Upon Request |
| Measurement Principle | Light Obscuration (LO) per ISO 11171 & ISO 4406 |
| Detection Range | 0.8 µm to 600 µm (sensor-dependent) |
| Accuracy | ±0.5% |
| Repeatability (RSD) | <2% |
| Resolution | <10% |
| Operating Temperature | 0–60 °C |
| Light Source | Semiconductor Laser |
| Number of Measurement Channels | 16 (user-configurable size thresholds within calibrated range) |
| Sample Flow Rate | 5–80 mL/min |
| Coincidence Limit | 12,000–24,000 particles/mL (sensor-dependent) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤200 W |
| Dimensions (Main Unit) | 360 × 370 × 700 mm |
| Dimensions (Air Pump) | 330 × 266 × 255 mm |
| Weight (Main Unit) | 30 kg |
| Weight (Air Pump) | 10 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0.1–10 mg/L (multi-segment calibration) |
| Repeatability | ≤5% RSD |
| Accuracy | ±5% of reading |
| LOD | 0.4 mg/L |
| Resolution | 0.01 mg/L |
| Single-Test Duration | 13 min (water bath heating) |
| Display | Backlit LCD with keypad interface |
| Data Storage | 30,000 measurement records with power-loss protection |
| Calibration Curves | 1 built-in standard curve + 96 user-defined curves |
| Connectivity | Ethernet port + USB 2.0 |
| Output | Integrated thermal printer |
| Light Source | Imported long-life cold LED (rated lifetime: 100,000 h) |
| Operating Modes | Standard mode / Continuous measurement mode |
| Reagent Compatibility | Dedicated pre-packaged CODMn test kits (ISO/GB-compliant) |
| Brand | Timepower |
|---|---|
| Model | TP107 |
| Type | Online Analyzer |
| Origin | Beijing, China |
| Manufacturer | Timepower (Producer) |
| Measurement Principle | Vanadomolybdophosphoric Yellow Colorimetry (Acidic Medium) |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Range Options | 0.00–20.00 mg/L or 0.00–50.00 mg/L |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | ≤±1% F.S./24 h |
| Response Time | < 4 min |
| Cycle Time | ~3 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temp. | 5–50 °C |
| Suspended Solids | < 5 µm, non-colloidal |
| Ambient Temp. | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (programmable) |
| Alarm Outputs | Independent per channel (flow loss, high/low limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 × 720 × 280 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Compliance | GB/T 6913–2008 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Model | TP140 |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Alarm Relays | 2 SPST (AC 220 V / DC 30 V, 3 A) |
| Display | 128 × 64 dot-matrix LCD with Chinese interface |
| Measurement Range | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% FS |
| Resolution | 0.01% |
| Repeatability | <1% FS |
| Temperature Compensation | Pt1000 sensor, 0–60 °C |
| Sample Temp. Range | 5–50 °C |
| Ambient Temp. Range | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Storage Temp. | −25–55 °C (electrode excluded |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 145 × 120 × 150 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.64 kg |
| Mounting | Panel-mount / wall-mount / rack-mount |
| Electrode Options | Flow-through / immersion / flanged (custom configurations available upon consultation) |
| Data Logging | Cyclic memory with auto-overflow overwrite |
| Brand | TimePower |
|---|---|
| Model | TP150 |
| Origin | Beijing, China |
| Manufacturer | TimePower Co., Ltd. |
| Measurement Range | 0.00–20.00 mg/L |
| Resolution | 0.01 mg/L (in mg/L range) / 0.1 µg/L (in µg/L range) |
| Repeatability | ≤1% FS |
| Stability | ±1.5% FS |
| Temperature Compensation Range | 0.1–80.0 °C |
| Water Sample Temperature Range | 5–80 °C |
| Ambient Temperature Range | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Relay Outputs | 2 SPST, AC220V/3A or DC30V/3A |
| Communication Interface | RS485 |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | <5 W |
| Enclosure Rating | IP65 |
| Dimensions | 142 × 125 × 155 mm (H×W×D) |
| Panel Cutout | 138 × 138 mm |
| Weight | 1.6 kg |
| Data Retention | >10 years after power loss |
| Response Time (T90) | <5 min at 25 °C |
| Sensor Type | Polarographic (Clark-type) with BJC membrane cap rated to 130 °C |
| Temperature Sensor | Pt1000 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP160 |
| Instrument Type | Industrial Online ORP Meter |
| Display | 128×64 Dot-Matrix LCD (Chinese Interface) |
| Measurement Range | ±2000 mV |
| Electrical Accuracy | ±1 mV |
| Resolution | 0.1 mV |
| Temperature Compensation Range | 0–60 °C |
| Sample Temperature Range | 5–60 °C |
| Sample Pressure Limit | < 0.6 MPa |
| Environmental Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temperature | −25–55 °C |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Output Signals | Isolated Current Output (0–10 mA / 0–20 mA / 4–20 mA), Load < 300 Ω |
| Relay Outputs | 2 SPST (AC 220 V / 3 A or DC 30 V / 3 A), Configurable Alarm Thresholds |
| Enclosure Rating | IP65 |
| Data Logging | Cyclic Storage with Auto-Overflow Management |
| Memory Retention After Power Loss | >10 Years |
| Dimensions (H×W×D) | 145 mm × 120 mm × 150 mm |
| Panel Cutout | 138 mm × 138 mm |
| Weight | 0.64 kg |
| Electrode Type | Pt-based Redox Electrode (Direct Potentiometric Measurement) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP304 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP304 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Model | TP304 |
| Origin | Beijing, China |
| Manufacturer | TimePower (Domestic Producer) |
| Measurement Principle | Photometric Colorimetry (Based on Lambert-Beer Law) |
| Display | 5.0-inch TFT color touchscreen (Chinese UI) |
| Range | 0.0–200 μg/L |
| Accuracy | ±3% F.S. |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% |
| Stability | ±1.5% F.S. / 4 h |
| Operating Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Data Storage | 256 entries (circular buffer) |
| Light Source | Imported monochromatic cold LED |
| Calibration | Automatic zero calibration (blank), periodic curve calibration recommended |
| Compliance Context | Designed for routine QC in power plant water chemistry per ASTM D1066, ISO 5667-3, and DL/T 938 (Chinese thermal power industry standard) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Benchtop Laboratory Analyzer |
| Model | TP306 |
| Measurement Principle | Molybdenum Blue Colorimetric Method (Silicomolybdic Acid Reduction) |
| Display | 5.0-inch TFT color touchscreen with Chinese UI |
| Optical Source | Imported monochromatic cold-light LED (peak λ = 650 nm ± 5 nm) |
| Detection Range | 0–200 µg/L SiO₂ (extendable to 1000 µg/L via dilution) |
| Resolution | 0.1 µg/L |
| Accuracy | ±2% FS or ±1 µg/L (whichever is greater) |
| Repeatability | ≤1.5% RSD |
| Blank Calibration | Automatic zero-point and electronic drift compensation |
| Data Storage | Cyclic memory for up to 256 test records |
| Power Supply | AC 220 V ± 10%, 50/60 Hz |
| Dimensions | 320 × 240 × 180 mm |
| Weight | 4.2 kg |
| Compliance | Designed per GB/T 12149–2019 (Chinese Standard for Silica Determination in Boiler Water and Feedwater), ASTM D859–22 (Standard Test Method for Silica in Water), and ISO 10523:2022 (Water Quality — Determination of pH) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP310 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameter | pH |
| Measurement Range | 0.00–14.00 pH |
| Accuracy | ±0.02 pH |
| Resolution | 0.01 pH |
| Input Impedance | ≥1×10¹² Ω |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Compensation Range | 0–60 °C |
| Temperature Sensor | Pt1000 |
| Sample Temperature Range | 5–60 °C |
| Ambient Temperature | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temperature | −25–55 °C (electrode excluded |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤5 W |
| Dimensions | 200 × 200 × 85 mm |
| Weight | 2.1 kg |
| Display | 5.0-inch capacitive color touchscreen, Chinese UI |
| Brand | TimePower |
|---|---|
| Model | TP 340 |
| Origin | Beijing, China |
| Manufacturer | TimePower Instrument Co., Ltd. |
| Type | Non-contact Inductive Conductivity-Based Concentration Analyzer |
| Measurement Range | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% F.S. |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Temperature Compensation | Pt1000 sensor, 0–60 °C |
| Sample Temp. | 5–50 °C |
| Ambient Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤5 W |
| Dimensions | 200 × 200 × 85 mm |
| Weight | 2.1 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 150 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 600 W (main) + 1000 W (auxiliary) |
| Temperature Sensor | Industrial Pt100 Platinum Resistance Thermometer |
| Timing Range | 1 min to 24 h |
| Time Display | LED digital |
| Temperature Display | 7-segment LED |
| Sample Capacity | Up to 12 copper strips (4 test wells per bath, configurable multi-bath operation) |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1800 W |
| Dimensions (W×D×H) | 480 × 360 × 520 mm |
| Weight | 18 kg |
| Compliance Standards | GB/T 5096, GB/T 7326, ASTM D130, ASTM D4048, SH/T 0232, SH/T 0023, ISO 6251 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP651 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±2 °C |
| Temperature Repeatability | ≤4 °C |
| Temperature Resolution | 0.1 °C |
| Bath Temperature Setpoints | 54 °C ±1 °C (standard), 82 °C ±1 °C (for viscous oils) |
| Stirring Duration | 5 min (automated) |
| Stirrer Positioning | Descends to 6 mm above cylinder bottom |
| Cylinder | 100 mL calibrated glass cylinder |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1600 W |
| Dimensions (W×D×H) | 510 mm × 360 mm × 580 mm |
| Net Weight | 23.5 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | TimePower |
|---|---|
| Model | TP683 |
| Measurement Principle | Oxygen Bomb Combustion with Mercury Nitrate or Barium Chloride Titration |
| Compliance | DL/T 433, GB/T 388 |
| Max Operating Pressure | ≥20 MPa |
| Ignition Voltage | 12–24 V DC |
| Repeatability (RSD) | ≤0.0006% (w/w) |
| Ambient Temperature Range | 10–40 °C |
| Relative Humidity | 30–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 300 × 300 × 390 mm |
| Cooling Method | Integrated High-Flow Air Cooling |
| Net Weight | 8.7 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP 691 |
| Pricing | Upon Request |
| Measurement Principle | Microscopic Filtration & Manual Particle Counting |
| Detection Threshold | ≥5 µm (maximum dimension) |
| Microscope Magnification | 100× with Integrated Illumination |
| Contamination Rating Range | NAS 1638 Classes 4–12 |
| Dimensions | 410 mm × 310 mm × 230 mm |
| Weight | 6.4 kg |
| Compliance Standards | DL/T 432, GB/T 20082, ISO 4406, NAS 1638, GB/T 18854, ISO 11171, GJB 420B, GJB 380.4A |