Unimicro Technologies
Filter
Showing 31–48 of 48 results
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | qSep™-3010 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Application | Organic Analysis |
| Voltage Range | 0 to ±30 kV |
| Cooling Method | Liquid Cooling |
| Capillary Temperature Control | Semiconductor-Based Peltier |
| Detector Options | UV/Vis (μUV/Vis), Laser-Induced Fluorescence (μLIF), Evaporative Light Scattering (μELSD), Electrochemical (μECD), Mass Spectrometry (MS) Interface |
| Injection Mode | Pressure- or Electrokinetic-Driven |
| Injection Volume Precision | 4 nL or 10 nL via Patented Loop Valve |
| Pressure Range | Low-Pressure Pneumatic |
| Column Oven Temperature Range | 4–50 °C |
| Compliance | GLP-ready software with audit trail, 21 CFR Part 11–compatible configuration available |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TriSep®-3000LIF |
| Detection Principle | Laser-Induced Fluorescence (LIF) |
| Excitation Wavelengths | 375 nm, 488 nm, 532 nm, 638 nm (custom wavelengths available) |
| Detection Mode | Dual-Beam |
| Light Source | Semiconductor Laser Diode |
| Compatible Systems | Capillary Electrophoresis (CE), Capillary Electrochromatography (CEC), Microbore HPLC, Capillary LC, Microfluidic Chips, Conventional HPLC |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Imported Instrument |
| Model | TriSep™-2100 |
| Instrument Type | High-Voltage Power Supply for Capillary Electrophoresis |
| Output Mode | Bipolar / Positive-only / Negative-only |
| Voltage Range | 0 to ±30 kV |
| Current Range | 0 to 100 µA |
| Max Output Power | 4 W |
| Weight | 12 kg |
| Display | Digital Voltage & Current Readout |
| Control | Front-panel Programmable Timing Ramp & Manual Setpoint |
| Protection | Integrated Overvoltage/Overcurrent Alarm and Shutdown |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UM 5800 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 460 × 330 × 220 mm |
| Operating Environment | 15–40 °C, RH < 90% |
| Nebulizer Gas | Nitrogen or compressed air |
| Gas Pressure Range | 2–5 bar |
| Gas Flow Rate | 1–4 L/min |
| Gas Flow Accuracy | ≤1% or ±0.02 L/min |
| Gas Pressure Detection Resolution | 0.01 bar |
| Evaporation Temperature Range | Ambient to 130 °C |
| Temperature Increment | 1 °C |
| Temperature Control Accuracy | ±1 °C |
| Liquid Flow Rate Compatibility | 10 μL/min – 3 mL/min |
| Baseline Noise | <0.03 mV |
| Baseline Drift | <0.03 mV/h |
| Minimum Detectable Mass | <1 ng |
| Typical Quantitative Range | 0.1 μg – 30 μg |
| Quantitative Reproducibility (RSD₆) | <2% |
| Light Source | 650 nm semiconductor laser |
| Detection Element | Photomultiplier tube (PMT) |
| Signal Output | 0–1 V DC |
| Interface | RS-232 |
| Alarm Functions | Real-time temperature, gas pressure, and flow rate monitoring |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Model | UM4800 |
| Evaporation Zone Temperature Range | Ambient to 130 °C |
| Nebulizing Gas | Nitrogen or Compressed Air |
| Gas Flow Rate | 1–4 L/min |
| Baseline Drift | <1.0 mV/h (under specified conditions: 1 mL/min flow, 10% methanol mobile phase, 40 °C evaporation temperature, 3 L/min gas flow) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UM5000 |
| Price Range | USD 7,000 – 14,000 (FOB Shanghai) |
| Compatible Instrument | High-Performance Liquid Chromatography (HPLC) Systems |
| Detector Type | Evaporative Light-Scattering Detector (ELSD) |
| Light Source | Laser Diode |
| Wavelength | 650 nm |
| Detection Principle | Light Scattering of Nebulized and Evaporated Analyte Particles |
| Operating Mode | Beam Transmission Method |
| Evaporation Temperature Range | Up to 130 °C (adjustable, low-temperature optimized) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Instrument Type | Evaporative Light-Scattering Detector (ELSD) |
| Model | UM5000A |
| Detection Principle | Nebulization–evaporation–light scattering |
| Light Source | 650 nm semiconductor laser diode |
| Detector | Photomultiplier tube (PMT) |
| Evaporation Zone Temperature Range | Ambient to 130 °C (±1 °C control accuracy) |
| Nebulizing Gas | Nitrogen or compressed air (2–5 bar, ±0.01 bar pressure accuracy |
| Solvent Flow Rate Compatibility | 10 µL/min – 3 mL/min |
| Detection Limit | <1 ng (glucose, direct injection) |
| Baseline Noise | <0.05 mV (at 1 mL/min) |
| Baseline Drift | <0.5 mV (at 1 mL/min) |
| Quantitative Range | 0.1–30 µg (glucose, HPLC) |
| Quantitative Repeatability | RSD₆ < 2% (glucose, 1 mL/min) |
| Signal Output | 0–10 mV DC or 0–1 V DC |
| Interface | RS232 |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software logging |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | UM5800 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Principle | Evaporative Light Scattering |
| Light Source | Semiconductor Laser |
| Power Supply | 220 V, 50 Hz |
| Dimensions (W×D×H) | 460 × 330 × 220 mm |
| Operating Temperature | 15–40 °C |
| Relative Humidity | <90% RH |
| Evaporation Temperature Range | Ambient to 130 °C |
| Temp. Increment | 1 °C |
| Temp. Accuracy | ±1 °C |
| Carrier Gas | Nitrogen or Compressed Air |
| Gas Input Pressure | 2–5 bar |
| Pressure Sensing Accuracy | 0.01 bar |
| Gas Flow Rate | 1–4 L/min |
| Flow Accuracy | ≤1% or ±0.02 L/min |
| Liquid Flow Compatibility | 10 μL/min – 3 mL/min |
| Baseline Noise | <0.03 mV |
| Baseline Drift | <0.3 mV/h |
| Limit of Detection (LOD) | <1 ng (on-column, glucose) |
| Typical Quantitative Range | 0.1–30 μg (glucose) |
| Precision (RSD₆) | <2% (glucose) |
| Signal Output | 0–1 V DC |
| Interface | RS-232 |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | UM5800Plus |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Light Source | Solid-State Laser |
| Detection Principle | Light Scattering of Nebulized and Dried Analyte Particles |
| Wavelength | Fixed-Wavelength Laser (Typical 650 nm) |
| Signal Output | Dual-Mode — Digital (USB/RS-232) and Analog (±2.4 V DC) |
| Gain Adjustment | 7-Step Programmable Gain Control |
| Method Storage Capacity | 100 Predefined Methods |
| Display | Integrated High-Resolution TFT Screen with Real-Time Chromatogram Rendering |
| Control Architecture | Fully Software-Reverse-Controlled (Temperature, Nebulizer Gas Flow, Gain, Detection Threshold) |
| Compliance | GLP-Ready with Audit Trail Logging, Password-Protected Access, Error Log Archiving |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | UNIEX-7700 |
| Compatible Instrument | Liquid Chromatography (LC) Systems |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Dual-Beam |
| Light Source | Semiconductor Laser Diode |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | URI-3000 RID |
| Detection Principle | Differential Refractive Index (dRI) |
| Wavelength Range | 0.25–512 µRIU |
| Light Source | Tungsten Halogen Lamp |
| Compatible Systems | HPLC (Universal Analog Output + Optional Digital Interface) |
| Compliance | Designed for GLP/GMP-aligned QC environments |
| Software Integration | Unimicro ChromaControl™ (Optional) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Single-beam |
| Detector Type | CCD Array Detector |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.1% T at 220 nm and 360 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Data Storage Capacity | 1000 measurement sets |
| Interface | USB port for U-disk data export |
| Language Support | Switchable English/Chinese UI |
| Software Option | PC-based remote control and advanced data analysis software (optional) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | TriSep-2100 |
| Compatible Instrument | HPLC Systems |
| Detector Type | Laser-Induced Fluorescence (LIF) Detector |
| Excitation Wavelength | 488 nm |
| Optical Configuration | Dual-Beam Design |
| Light Source | Solid-State Semiconductor Laser |
| Detection Limit | 1 × 10⁻¹¹ mol/L |
| Photomultiplier Tube (PMT) | High-Sensitivity, Wide Dynamic Range, Single-Photon Counting Capable |
| Optical Path Design | Patented Modular Flow Cell with Precision Window Positioning Mechanism |
| Software | Integrated Data Acquisition and Quantitative Analysis Suite Supporting Baseline Correction, Peak Integration, Calibration Curve Fitting, and Audit-Trail Logging |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | 2100 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC)-compatible pCEC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–250 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Detection Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | UV-Vis Absorbance Detector |
| Model | Trisep®-2100 |
| Light Sources | Deuterium Lamp & Tungsten-Halogen Lamp |
| Wavelength Range | 190–600 nm |
| Spectral Bandwidth | 8 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Drift | ≤5 × 10⁻⁴ AU/h |
| Baseline Noise | ≤6 × 10⁻⁶ AU (RMS, 1 s time constant) |
| Absorbance Range | 0.0001–2.56 AU Full Scale (AUFS) |
| D₂ Lamp Lifetime | ≥2000 h |
| Operating Temperature | 4–35 °C |
| Dimensions (W×H×D) | 260 × 140 × 430 mm |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TriSep®-3000 High-Efficiency Microfluidic Electro-HPLC System |
| Instrument Type | Nanoflow Liquid Chromatograph |
| Application Profile | Specialized Analytical Instrument |
| Flow Rate Range | 0.001–10.00 mL/min |
| Maximum Pressure | 40 MPa |
| Flow Precision | <0.06% RSD |
| Sample Tray Capacity | 1.5 mL vials (105 positions) or 5 mL vials (10 positions) |
| Injection Volume Range | 20 nL, 50 nL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Compatible System | Liquid Chromatography (HPLC/UHPLC) |
| Light Source | Laser Diode |
| Detection Principle | Laser-based light scattering after nebulization and solvent evaporation |
| Wavelength | Fixed laser wavelength (typical 635–650 nm) |
| Noise Level | < 0.01 mV |
| Baseline Drift | < 0.1 mV |
| Detection Limit (LOD) | < 1 × 10⁻⁷ g on-column (for typical non-volatile analytes) |
| Signal Gain | Multi-step adjustable (6–8 discrete gain levels) |
| Temperature Control | Dual-zone heated drift tube (ambient to 120 °C, ±0.5 °C stability) |
| Operating Modes | High-Temp Mode & Low-Temp Mode (user-selectable) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | UV-6000 / UV-8000 / UV-9000 |
| Optical Design | Czerny-Turner monochromator with high-resolution grating |
| Wavelength Range | 190–1100 nm |
| Photometric Range | –4.0 to 4.0 A |
| Display | 7-inch color TFT touchscreen |
| Sample Handling | 4-position manual cuvette holder (10–50 mm pathlength compatible) |
| Data Storage | Internal memory + USB flash drive export |
| Connectivity | Bluetooth 4.2 (printer support), USB host/device, RS-232 optional |
| Control Interface | Touchscreen + physical keypad dual-mode operation |
| Lamp System | Replaceable D₂ and W lamp modules with front-access flange-mount design |
| Software | PC-based remote control suite with GLP-compliant audit trail, method storage, and report generation |