WIGGENS
Filter
Showing 1–30 of 69 results
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | 2755-25 |
| Configuration | Includes SL29GL-A glass cold trap, Dewar vessel, lid, exhaust tubing, and 25 L LN₂ storage tank |
| Compliance | Designed for cryogenic vacuum applications requiring stable condensation surface temperature and reproducible low-temperature operation |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | 2760-25 |
| Application | Cryogenic Sample Immersion & Thermal Contraction Testing |
| Includes | 25 L LN₂ Storage Dewar, Dual Temperature Sensors, Control Unit, Transfer Tubing, Vent Line, Two Sample Supports |
| Power Supply | 24 V DC |
| Valve Type | Solenoid Valve (24 V DC) |
| Sensor Principle | Cryogenic Temperature Threshold Detection |
| Compliance | Designed for GLP-aligned laboratory environments |
| Brand | WIGGENS |
|---|---|
| Origin | Shanghai, China |
| Model | A410 |
| Pump Type | Dual-Stage Diaphragm Pump |
| Ultimate Vacuum | ≤13 mbar |
| Flow Rate | ≤25 L/min |
| Motor Speed | 1450 rpm |
| Dimensions (W×D×H) | 230 × 155 × 173 mm |
| Weight | 4.5 kg |
| Rated Power | 95 W |
| Noise Level | 50 dB(A) |
| Power Supply | 220–240 V / 50 Hz |
| Inlet/Outlet Port | 10 mm ID |
| Protection | Thermal Overload Cut-Off |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Autoloop Pro |
| Sterilization Method | Flame-based (compatible with WIGGENS Fuego Bunsen burners) |
| Control System | Microprocessor-controlled with LED interface |
| Loop Capacity | 1–4 loops |
| Sterilization Time Range | 1–15 s (adjustable in 1-s increments) |
| Cooling Time Range | 1–45 s (adjustable in 1-s increments) |
| Auto-Shutdown | Yes (configurable: 15 min or 1 hr) |
| Rotation Direction | Bidirectional (left/right selectable) |
| Flame Intensity | Two preset levels |
| Status Indication | Dual-color LED (red = hot, green = cooled) |
| Construction | Stainless steel housing with heat-resistant tempered glass display cover |
| Dimensions (W×D×H) | 135 × 180 × 305 mm |
| Weight | 1200 g |
| Compliance | Designed for GLP-compliant microbiological workflows |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac 225 |
| Vacuum Level | ≥100 mbar |
| Flow Rate | ≤25 L/min |
| Weight | 4.3 kg |
| Dimensions (L×W×H) | 37 × 15 × 25 cm |
| Waste Bottle Capacity | 1000 mL (1 pc) |
| Filtration | 0.2 µm PTFE disc filter |
| Sterilization | Autoclavable (waste bottle & filter) |
| Foot Switch | Included |
| Accessories | 4 suction sets |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac 235 |
| Vacuum Level | ≥100 mbar |
| Flow Rate | ≤35 L/min |
| Weight | 6.9 kg |
| Dimensions (W×D×H) | 27 × 30 × 28 cm |
| Waste Bottle Capacity | 1500 mL × 2 |
| Filtration | 0.2 µm PTFE disc filter |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Foot Switch | Included |
| Accessories | 4-piece aspiration kit |
| Compliance | CE, ISO 13485-design aligned |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac 240 |
| Vacuum Level | ≥80 mbar |
| Flow Rate | ≤40 L/min |
| Foot Switch | Yes |
| Weight | 12 kg |
| Dimensions (L×W×H) | 54 × 26 × 35 cm |
| Waste Bottle Capacity | 3000 mL × 1 |
| Filtration | 0.2 µm PTFE disc filter |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Accessories Included | 4-piece aspiration kit |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac320A |
| Pump Flow Rate | 34 L/min |
| Ultimate Vacuum | ≤150 mbar |
| Waste Bottle Capacity | 3000 mL (PC) |
| Number of Filtration Ports | 3 |
| Filtration Plate Material | SS316 Stainless Steel |
| Filter Membrane Diameter | 47 mm / 50 mm |
| Filtration Flask Capacity | 300 mL |
| Effective Filtration Area per Port | 9.6 cm² |
| Hose Inner Diameter | 8 mm |
| Magnetic Flask Retention System | Yes |
| Sterilization Compatibility | Autoclave, Dry Heat, Flame |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac330 |
| Filtration Positions | 3 |
| Filter Diameter | 47/50 mm |
| Effective Filtration Area | 9.6 cm² |
| Hose Connection | 8 mm ID |
| Dimensions (L×W×H) | 50 × 15 × 15 cm |
| Filter Holder Material | ASTM F138-certified SS316 stainless steel |
| Sterilization Compatibility | Autoclave (121 °C, 20 min), dry heat (180 °C), and flame sterilization |
| Independent Valve Control | Yes, per position |
| Compatible Flask Volumes | 100 mL, 300 mL, 500 mL (all SS316) |
| Regulatory Compliance | Designed for GLP/GMP environments with traceable component sourcing |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac330B |
| Pump Flow Rate | 34 L/min |
| Ultimate Vacuum | ≤150 mbar |
| Waste Bottle Capacity | 3000 mL (PC) |
| Number of Filtration Ports | 3 |
| Filtration Plate Material | SS316 Stainless Steel |
| Filter Membrane Diameter | 47 mm / 50 mm |
| Filter Flask Volume Options | 100 mL, 300 mL, 500 mL |
| Stainless Steel Filter Flask Capacity | 100 mL |
| Effective Filtration Area per Port | 9.6 cm² |
| Hose Inner Diameter | 8 mm |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac341 |
| Filter Positions | 3 |
| Filter Diameter | 47/50 mm |
| Effective Filtration Area | 9.6 cm² |
| Tubing ID | 8 mm |
| Dimensions (L×W×H) | 50 × 15 × 23 cm |
| Filter Flask Material | SS316 Stainless Steel |
| Filter Flask Volume | 100 mL |
| Sterilization Compatibility | Autoclave, Dry Heat, Flame |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Biovac350A |
| Vacuum Type | Piston Pump |
| Power | 250 W |
| Ultimate Vacuum | ≥60 mbar |
| Maximum Flow Rate | ≤80 L/min |
| Weight | 19.5 kg |
| Dimensions (W×D×H) | 45 × 35 × 84 cm |
| Collection Bottles | Two 3000 mL PC bottles (series-connected) |
| Filtration | 0.2 µm PTFE disc filter |
| Safety Features | Liquid-level float switch in bottle, autoclavable components |
| Mobility | Casters with brakes |
| Control | Foot switch |
| Vacuum Gauge | Analog display |
| Maintenance | Oil-free operation |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioVac630B |
| Pump Flow Rate | 58 L/min |
| Ultimate Vacuum | ≤150 mbar |
| Waste Bottle Capacity | 3000 mL (Polycarbonate) |
| Number of Filtration Positions | 6 |
| Filtration Plate Material | SS316 Stainless Steel |
| Filter Membrane Diameter | 47 mm or 50 mm |
| Filter Flask Volumes | 100 mL, 300 mL, 500 mL (compatible) |
| Effective Filtration Area per Position | 9.6 cm² |
| Tubing Inner Diameter | 8 mm |
| Sterilization Compatibility | Autoclavable, Dry Heat (up to 250 °C), Flame-Sterilizable |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | C300A |
| Vacuum Level | ≥210 mbar |
| Pumping Speed | ≤22 L/min |
| Collection Bottle Capacity | 1000 mL |
| Filter Membrane Diameter | 47/50 mm |
| Filtration Funnel Capacity | 300 mL |
| Effective Filtration Area | 8 cm² |
| Tubing Inner Diameter | 8 mm |
| Power Supply | 220–240 V / 50 Hz |
| Rated Power | 60 W |
| Includes | C300 Vacuum Pump, VF3 Glass Filtration Kit, Disc Filters, High-Pressure Silicone Tubing |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioMIX1 |
| Speed Range | 2–250 rpm |
| Stirring Capacity | 5–5000 mL |
| Power Consumption | 6 W |
| Operating Temperature | −10 to 50 °C (up to 80% RH) |
| Enclosure Material | Stainless Steel (IP64) |
| Dimensions (W×D×H) | 180×230×38 mm |
| Weight | 1.4 kg |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Control Unit | Integrated Display & Drive |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | ChemVak C400 |
| Pump Type | Diaphragm Vacuum Pump |
| Ultimate Vacuum | ≤120 mbar |
| Flow Rate | ≤34 L/min |
| Motor Power | 95 W |
| Dimensions (W×D×H) | 294 × 156 × 195 mm |
| Weight | 8.5 kg |
| Noise Level | ≤50 dB(A) |
| Motor Speed | 1450 rpm |
| Inlet/Outlet Port Size | 10 mm |
| Electrical Supply | 220–240 V / 50 Hz |
| Protection Features | Thermal Overload Cut-off, Fuse Protection |
| Construction | PTFE-wetted Parts, Hermetically Sealed Drive Chamber |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | DIGICEN 21/21R |
| Instrument Type | Benchtop Refrigerated Microplate Centrifuge |
| Max RCF | 26480 × g |
| Max Speed | 16500 rpm |
| Sample Capacity | 4 × 100 mL |
| Acceleration Time | ≥5 s |
| Operating Noise | ≤60 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R449A |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, Directive 2011/65/EU, 2012/19/EU, 98/79/EC |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Digtor 22 C |
| Instrument Type | Benchtop Centrifuge |
| Max. Speed | 3000 rpm |
| Max. RCF | 2425 × g |
| Max. Capacity | 4 × 100 mL (with 6" or 8" tubes) |
| Temperature Range | RT + 5 °C to 80 °C (1 °C increment, °C/°F selectable) |
| Acceleration/Deceleration | 175 programmable slopes (PCBS) |
| Unbalance Detection | ULS (Unbalance Location System) with positional display |
| Timer Range | 1 s to 99 h (1 s increment) |
| Noise Level | < 60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010 |
| Certifications | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Digtor 22 C-8 |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Maximum Capacity | 8 × 100 mL (6" or 8" tubes) |
| Max RCF | 2425 × g |
| Max Speed | 3000 rpm |
| Temperature Range | RT + 5 °C to 80 °C (adjustable in 1 °C steps) |
| Noise Level | < 60 dB(A) |
| Compliance | ASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007, D5546 |
| Safety Certifications | EN 61010-1, EN 61010-2-020, EN 61010-2-010, EN 61326-1, EN 61326-2-6 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Digtor 22 C-U |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 22,000 rpm |
| Max RCF | 48,700 × g (calculated at 22,000 rpm with 100 mm rotor radius) |
| Max Capacity | 4 × 100 mL |
| Rotor Type | Fixed-angle |
| Application Class | Cellular & Bacterial Separation |
| Compliance | ASTM D91, D893, D2273, D2709, D5546 |
| Safety Certifications | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Dimensions (W×D×H) | 640 × 650 × 400 mm |
| Net Weight | 77 kg |
| Power Supply | 220–230 V, 50–60 Hz |
| Power Consumption | 400 W |
| Noise Level | <60 dB(A) |
| Temperature Control Range | –10 °C to +40 °C |
| Display | TFT color touchscreen, readable at >3 m |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Dragon 200 |
| Fuel Type | Liquefied Petroleum Gas (LPG) / Natural Gas |
| Fuel Consumption | 0.2 kg/h (LPG) |
| Maximum Flame Temperature | 1350 °C (LPG) |
| Fuel Capacity | 45 g (butane) |
| Continuous Operation Time | 60 min |
| Dimensions (L×W×H) | 92 × 115 × 79 mm |
| Net Weight | 407 g |
| Ignition | Electronic Piezoelectric Igniter |
| Flame Adjustment | Continuously Variable Air/Gas Ratio Control |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Dragon 220 |
| Fuel Type | n-Butane |
| Fuel Consumption | 45 g per 60 min |
| Maximum Flame Temperature | 1300 °C |
| Fuel Capacity | 45 g |
| Continuous Operation Time | 60 min |
| Dimensions (L×W×H) | 94 × 115 × 78 mm |
| Net Weight | 425 g |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Dragon |
| Maximum Flame Temperature | 1300 °C |
| Fuel Consumption | 45 g/h |
| Compatible Fuel | n-Butane |
| Ignition Type | Piezoelectric Electronic Ignition |
| Design Variant | Tabletop (Dragon 200 & Dragon 220), Angled Flame Configuration (Dragon 220) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Dragon100 |
| Fuel Type | n-Butane |
| Fuel Consumption | 45 g per 60 min |
| Maximum Flame Temperature | 1300 °C |
| Fuel Capacity | 45 g |
| Continuous Operation Time | 60 min |
| Dimensions (L×W×H) | 161 × 137 × 79 mm |
| Net Weight | 380 g |
| Safety Ignition Switch | Integrated Piezoelectric Igniter |
| Flame Adjustment | Continuously Variable Needle Valve |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Ecoloop |
| Control Mode | Manual |
| Rotation Mechanism | Motorized, Bidirectional (Left/Right Adjustable) |
| Sterilization Method | Open-flame thermal sterilization using compatible WIGGENS-Fuego Bunsen burners |
| Detection System | Integrated optical sensor for loop presence/absence detection |
| Auto Shut-off | Yes, configurable at 15 min or 60 min |
| Flame Intensity Settings | 2 levels |
| Post-sterilization Cooling Options | 2 selectable durations |
| Status Indication | Dual-color LED (red = hot, green = cooled) |
| Construction Material | Stainless steel |
| Dimensions (W×D×H) | 120 × 150 × 395 mm |
| Weight | 1800 g |
| Compliance | Designed for ISO 13485-aligned lab environments |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | Ecoloop |
| Control Mode | Manual |
| Rotation Mechanism | Motorized, Bidirectional (Left/Right Adjustable) |
| Sterilization Time Range | 1–15 s |
| Cooling Time Range | 1–45 s |
| Auto-Shutdown | Yes (15 min / 1 h selectable) |
| Detection System | Integrated Optical Sensor for Loop Presence/Absence |
| Flame Intensity Settings | 2 Levels |
| Post-Sterilization Status Indication | Dual-Color LED (Red = Hot, Green = Cooled) |
| Construction Material | Stainless Steel |
| Dimensions (W×D×H) | 120 × 150 × 395 mm |
| Weight | 1800 g |
| Compatibility | All WIGGENS-Fuego Bunsen Burners |
| Mounting | Benchtop or Cleanbench Integrated Fixture |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | HD 2070.2 |
| Ultrasonic Power Output | ≤100 W |
| Frequency Range | 20–25 kHz |
| Compatible Vessel Volume | 0.5–500 mL |
| Transducer Diameter × Length | 70 × 150 mm |
| Optional Probe Diameters | 2, 3, 6, and 13 mm |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | LN2-4 |
| Sensor Inputs | 4-channel PT100 (configurable as level or temperature) |
| Output Channels | 2 relay outputs (for solenoid valve control and alarm) |
| Communication Interface | RS-232 and USB |
| Control Logic | Dual-threshold (high/low level) hysteresis-based automatic fill cycle |
| Calibration | Single-point user calibration per sensor channel |
| Power Supply | 24 V DC |
| Enclosure Rating | IP65 (industrial-grade housing) |
| Compliance | CE-marked, RoHS-compliant, designed for Class I, Div 2 hazardous location compatibility (per IEC 60079-0) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | MAGNUS 22 |
| Instrument Type | Floor-standing Centrifuge |
| Maximum Capacity | 4 × 750 mL |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 × g |
| Rotor Type | Horizontal (Swinging-Bucket) |
| Acceleration/Deceleration Control | Programmable PCBS with 175 selectable ramp profiles |
| Unbalance Detection | ULS (Unbalance Location System) with positional identification |
| Display | TFT color touchscreen (≥3 m visibility) |
| Timer Range | 1 s to 99 h, programmable in 1 s increments |
| Noise Level | <60 dB(A) |
| Motor | Brushless, maintenance-free |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | MAGNUS 22R |
| Instrument Type | Floor-standing Refrigerated Centrifuge |
| Max. Capacity | 4 × 750 mL |
| Max. Speed | 14,300 rpm |
| Max. RCF | 21,948 × g |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R449A |
| Noise Level | <60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Power Supply | 220–230 V, 50–60 Hz, 1050 W |
| Dimensions (W × D × H) | 650 × 650 × 930 mm |
| Net Weight | 145 kg |