WinNano
Filter
Showing all 19 results
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Winner2000 |
| Price Range | USD 0–15,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–300 µm |
| Repeatability | <1% RSD (NIST-traceable standard reference material) |
| Measurement Time | <2 min per run |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Winner2000ZD |
| Price Range | USD 0–14,500 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Benchtop Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–300 µm |
| Repeatability | <0.5% RSD (D50 of NIST-traceable standard reference material) |
| Measurement Time | <120 s per run |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–300 µm |
| Reproducibility | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Dispersion Method | Wet Dispersion with Integrated Ultrasonic Stirring & Circulation |
| Optical Design | Convergent Beam Fourier Transform with Multi-Angle Ring Detector Array |
| Compliance | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Winner2006 |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–1000 µm |
| Repeatability | <0.5% RSD (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Standards Compliance | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Number of Detection Channels | 90 (Winner2006A) / 86 (Winner2006B) |
| Primary Laser | λ = 639 nm, P > 2 mW |
| Secondary Laser | λ = 532 nm, P > 2 mW |
| Ultrasonic Dispersion | f = 40 kHz, P = 60 W, adjustable duration |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 17 L/min, P = 15 W |
| Sample Cell Volume | 450 mL |
| Auto-Alignment System | Patented 3D motorized alignment (ZL201320835882.4) |
| Dispersion Module | Integrated wet dispersion unit with stirring, ultrasonication, circulation, and drainage (ZL201010533181.6) |
| Dual-Beam Optical Design | Patented dual-laser/dual-beam configuration (ZL200720025702.0) |
| Dimensions | 900 × 400 × 500 mm |
| Weight | 40 kg |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Winner2008 |
| Pricing Range | USD 21,000 – 28,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–2000 µm |
| Repeatability | ≤0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Winner2008A |
| Price Range | USD 14,000 – 21,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–2000 µm |
| Repeatability | <1% RSD (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Winner2009 |
| Price Range | USD 14,000 – 21,000 (FOB Qingdao) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–2000 µm |
| Repeatability | <1% RSD (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Compliance Standards | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Optical Alignment | Fully Automated 3D Motorized Centering System (Patent ZL201320835882.4) |
| Laser Sources | Dual-wavelength — Main He–Ne λ = 639 nm, P > 2 mW |
| Detection Angle | 0.0155°–164° |
| Detector Channels | 116 |
| Ultrasonic Dispersion | f = 40 kHz, P = 60 W, time-adjustable |
| Stirring Speed | 0–3000 rpm |
| Circulation Flow Rate | 3.6 L/min, P = 29 W |
| Sample Cell Volume | 550 mL |
| Dimensions (Analyzer Unit) | 1200 × 420 × 420 mm |
| Dimensions (Wet Dispersion Unit) | 455 × 310 × 335 mm |
| Weight | 58 kg (analyzer) + 15 kg (disperser) |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | Winner2018 |
| Price Range | USD 0–14,500 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–450 µm |
| Repeatability | <1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Standards Compliance | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Number of Detection Channels | 80 |
| Optical Alignment | Fully Automatic Real-Time Centering System |
| Laser Source | He–Ne, λ = 639 nm, P > 2 mW |
| Ultrasonic Dispersion | f = 40 kHz, P = 60 W, adjustable duration |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 8 L/min, P = 10 W |
| Standard Sample Cell Volume | 350 mL |
| Optional Micro-Cell Volume | 10 mL |
| Dimensions | 822 × 365 × 495 mm |
| Weight | 40 kg |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Wet-Dispersion Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–450 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Dispersion Method | Integrated Wet Dispersion System with Ultrasonication, Stirring & Circulation |
| Optical Design | Convergent Beam Fourier Transform with Extended Low-Angle Detection |
| Standard Compliance | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Laser Source | λ = 639 nm, P > 2 mW |
| Ultrasonic Frequency | 40 kHz, Power: 60 W (adjustable duration) |
| Stirring Speed | 0–3000 rpm (stepless control) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL (standard), 10 mL (optional micro-cell) |
| Auto-Alignment | Fully Motorized Optical Centering System |
| Dimensions | 822 × 365 × 495 mm |
| Weight | 40 kg |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Model | Winner2309A PRO |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | Wet: 0.01–3500 µm |
| Dry | 0.1–3000 µm |
| Repeatability | ≤0.5% (wet), ≤1.0% (dry, D50 of certified reference material) |
| Measurement Time | 10–120 s |
| Laser Sources | Dual-wavelength—639 nm (≥2 mW), 405 nm (≥2 mW) |
| Optical Alignment | Fully Automated, 0.1 µm precision |
| Data Acquisition Rate | Up to 10 kHz |
| Compliance | GB/T 19077–2016, ISO 13320:2020, Q/0100JWN001–2024 |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–300 µm |
| Repeatability | ≥99% |
| Measurement Time | 10–120 s |
| Dispersing Medium | Compressed Air |
| Optical Design | Convergent Beam Fourier Transform |
| Laser Wavelength | 639 nm |
| Laser Power | >2 mW |
| Compliance Standards | GB/T 19077–2016, ISO 13320:2020, Q/0100JWN001–2024 |
| Accuracy (D50) | ≤1% (NIST-traceable reference standards) |
| Channel Count | 40 |
| SOP Support | Yes |
| Auto-Alignment | Yes |
| Dimensions (Host) | 765 × 450 × 325 mm |
| Weight (Host) | 26 kg |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Winner3005 |
| Price Range | USD 21,000–28,000 (FOB) |
| Dispersion Method | Dry dispersion using turbulent airflow |
| Measurement Range | 0.1–500 µm |
| Repeatability | < 1% RSD (D50 of certified reference material) |
| Measurement Time | < 60 s per run |
| Laser Source | He-Ne, λ = 632.8 nm, P > 2 mW, lifetime > 25,000 h |
| Detector Channels | 40-channel annular photodetector array |
| Alignment | Motorized auto-alignment with micron-level precision |
| Feed System | Automated vibratory feeder + patented powder jet pump |
| Air Supply | Oil-free, silent compressor |
| Dimensions | 880 × 400 × 300 mm |
| Weight | 36 kg |
| Compliance | GB/T 19077.1–2008 |
| ISO 13320 | 2016 |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Winner 3008 |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–2000 µm |
| Repeatability | <1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Winner3009 |
| Dispersion Method | Dry Dispersion |
| Measurement Range | 0.1–2000 µm |
| Repeatability | <1% |
| Measurement Time | <1 min |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Winner3009 |
| Price Range | USD 14,000 – 21,000 |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–2000 µm |
| Repeatability | <1% |
| Measurement Time | <1 min |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Winner 311XP |
| Price Range | USD 0–14,500 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Benchtop Laser Particle Size Analyzer |
| Measurement Range | 0.1–100 µm |
| Repeatability | <1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Standard Compliance | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Optical Configuration | Single-beam collimated laser (λ = 650 nm, P > 1 mW), dual-lens dual-array detector system |
| Sampling Zone | Open-tube design, 60 mm effective path length |
| Dimensions | 660 × 260 × 450 mm |
| Weight | 19 kg |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Winner602 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Particle Size Range | 2–200 µm |
| Resolution | Better than 10% (per GB/T 18854–2002 / ISO 11171:1999) |
| Coincidence Error | ≤5% at 10,000 particles/mL |
| Size Channels | 5, 15, 25, 50, 100 µm |
| Sample Volume | 5 mL (±1% accuracy) |
| Flow Rate | 25 mL/min |
| Dispersion Method | Magnetic Stirring |
| Display & Interface | Color LCD + Touchscreen |
| Laser Source | Semiconductor Diode, λ = 635 nm |
| Compliance | GB/T 18854–2002, ISO 11171:1999 |
| Brand | WinNano |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | Winner602 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Particle Size Range | 2–200 µm |
| Resolution | Better than 10% (per GB/T 18854–2002) |
| Coincidence Error | ≤5% at 10,000 particles/mL |
| Size Channels | 5, 15, 25, 50, 100 µm |
| Sample Volume | 5 mL |
| Volume Accuracy | ±1% |
| Flow Rate | 25 mL/min |
| Dispersion Method | Magnetic Stirring |
| Display & Interface | Color LCD + Touchscreen |
| Laser Source | Semiconductor Laser, λ = 635 nm |
| Compliance Standard | GB/T 18854–2002 (equivalent to ISO 11171:1999) |
| Brand | WinNano |
|---|---|
| Model | Winner603 |
| Measurement Principle | Light Obscuration (LO) |
| Particle Size Range | 1–200 µm |
| Repeatability | ≤5% at 10,000 particles/mL |
| Measurement Time | 30 s per sample |
| Dispersion Method | Wet Dispersion |
| Sample Volume | 5–100 mL (±1% accuracy) |
| Flow Rate | 5–25 mL/min |
| Operating Pressure Range | −0.1 to 0.7 MPa |
| Max. Fluid Viscosity | 350 mm²/s |
| Laser Source | Semiconductor laser, λ = 650 nm |
| Compliance Standards | NAS 1638, ISO 4406:1999 (GB/T 14039–2002), ISO 11218:1993 (GJB 420A–1996), DL/T 432–2007, ISO 11171:1999 (GB/T 18854–2002) |