Zahner
Filter
Showing all 10 results
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | CIMPS-Pro Zennium |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A, ±10 A |
| Current Accuracy | 0.02% of reading |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V, ±20 V |
| AC Impedance Frequency Range | 10 µHz – 8 MHz |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7 |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Accuracy | < 0.0025% |
| Potential Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | ±2 aA (2 × 10⁻¹⁸ A) |
| Small-Signal Rise Time | 150 ns – 200 µs (5 auto-ranging steps) |
| IR Compensation | Real-time, adaptive |
| Grounding Mode | Switchable floating/grounded |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7c |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Voltage Scan Range | ±14 V |
| Potentiostatic Range | ±5 V / ±14 V |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | 2 × 10⁻¹⁸ A |
| Input Impedance | >10 TΩ (HIZ option: 1000 TΩ) |
| AC Voltage Perturbation | 0–6 V (24-bit resolution) |
| AC Current Perturbation | 0–2 A (24-bit, 12 ranges) |
| Grounding Modes | Grounded & Floating |
| IR Compensation Range | 0–10 MΩ |
| Bandwidth | DC–6 MHz |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| CV Scan Rate | up to 10,000 V/s (with ADF high-speed option) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7x |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±4 A |
| EIS Frequency Range | 10 µHz – 12 MHz |
| Potentiostat Bandwidth | DC – 15 MHz |
| ADC Resolution | 32 bit |
| Input Impedance | >10 TΩ |
| Applied Potential Range | ±15 V |
| Cell Voltage Range | ±32 V |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | ±2 aA (±2 × 10⁻¹⁸ A) |
| Output Current Accuracy | ±0.025% of reading ± 0.01% of FS (≥3 µA to 300 mA) |
| Rise Time (Small Signal) | 150 ns – 200 µs (5 auto-ranging steps) |
| IR Compensation | Real-time, adaptive EIS-based |
| Grounding Mode | Switchable floating/grounded |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| Software Platform | Zahner Lab (Windows 11, Linux, macOS compatible) |
| API Support | Python/C++ SDK included |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium Pro |
| Current Range | ±3 A |
| Current Resolution | ±2 aA |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32 bit |
| Bandwidth | 10 MHz |
| Voltage Resolution | 3 nV |
| Small-Signal Rise Time | 150 ns – 200 µs (5 steps) |
| Frequency Accuracy | 0.0025% |
| Frequency Resolution | 0.0025%, 10,000 steps/decade |
| Impedance Measurement Range | 10 µΩ to 100 GΩ (depending on probe configuration) |
| IR Compensation | Real-time, adaptive |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium X |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±4 A |
| Current Accuracy | ±0.02% of reading + ±0.01% of full scale (1 µA–100 mA), ±0.2% of reading + ±0.1% of full scale (100 mA–3 A), ±0.2% of reading + ±0.1% of full scale (10 nA–1 µA) |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| Compliance Voltage | ±32 V |
| EIS Frequency Range | 10 µHz–12 MHz |
| Frequency Accuracy | 0.0025% |
| Frequency Resolution | 10,000 steps/decade |
| Input Impedance | >10 TΩ |
| Voltage Resolution | 3 nV |
| Current Resolution | ±5 aA (32-bit DAC/ADC) |
| Bandwidth | 15 MHz |
| IR Compensation | Real-time, automatic EIS-based compensation |
| Grounding Mode | Switchable floating/grounded configuration |
| ADC/DAC Resolution | 32-bit HDP (High Dynamic Precision) architecture |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium X |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±4 A |
| Current Accuracy | ±0.02% of reading + ±0.01% of full scale (1 µA–100 mA) / ±0.2% of reading + ±0.1% of full scale (100 mA–3 A) / ±0.2% of reading + ±0.1% of full scale (10 nA–1 µA) |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz–12 MHz |
| Input Impedance | >10 TΩ |
| Voltage Resolution | 3 nV |
| Current Resolution | ±2 aA (±2×10⁻¹⁸ A) |
| ADC Resolution | 32 bit |
| Bandwidth | 15 MHz |
| IR Compensation | Real-time, automatic |
| Grounding Mode | Switchable floating/grounded |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium XC |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | 0.04% |
| Potential Accuracy | 100 µV |
| Potentiostatic Range | ±14 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Input Impedance | 10 TΩ (optional Hi-Z: 1000 TΩ) |
| EIS Accuracy | ±0.2% (100 mΩ–10 MΩ), ±2% (1 mΩ–100 mΩ or 10 MΩ–10 GΩ) |
| AC Perturbation Amplitude | 0–6 V (18-bit resolution) |
| Grounding Modes | Grounded & Switchable Floating Ground |
| IR Compensation | Real-time, automatic, 0–10 MΩ range |
| Bandwidth | 6 MHz |
| CV Scan Rate | up to 10,000 V/s (with ADF high-speed option) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium XC |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A |
| Current Accuracy | 0.04% |
| Potential Accuracy | 100 µV |
| Potentiostatic Range | ±14 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Current Resolution | 2 × 10⁻¹⁸ A |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Input Impedance | 10 TΩ (optional Hi-Z: 1000 TΩ) |
| EIS Accuracy | ±0.2% @ 100 mΩ–10 MΩ |
| AC Perturbation Amplitude | 0–6 V (18-bit resolution) |
| Grounding Modes | Grounded & Floating (for high-isolation applications, e.g., autoclaves, buried pipelines) |
| IR Compensation | Real-time automatic, 0–10 MΩ range |
| Bandwidth | 6 MHz |
| Software | Thales XT (real-time control, multi-channel visualization, offline analysis via Zahner Analysis) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | ZenniumPro |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Resolution | ±5 aA |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Bandwidth | 10 MHz |
| Voltage Resolution | 3 nV |
| IR Compensation | Real-time, automatic |
| Grounding Modes | Switchable floating/grounded |
| Small-Signal Rise Time | 150 ns – 200 µs (5 steps) |
| Impedance Accuracy | 1 mΩ–10 GΩ (±2%), 100 mΩ–10 MΩ (±0.2%) in POT mode |
| Software | Thales XT + Zahner Analysis (EIS fitting, CIMPS, Z-HIT, NFRA) |