Capillary Electrophoresis System
Filter
Showing all 20 results
| Brand | AES |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CEInfinite |
| Voltage Input | 100/240 VAC, 50–60 Hz |
| Cooling Method | Liquid-based Thermostatic Control |
| Sample Temperature Range | 4–10 °C |
| Detector | Scientific CMOS (sCMOS) Imaging Sensor |
| Separation Mode | Voltage Gradient iCIEF |
| Sample Introduction | Automated Capillary Injection |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 3D CE |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Application | Organic Analysis |
| Detection | Diode Array Detector (DAD) |
| Capillary Temperature Control | Peltier + High-Velocity Air Cooling (10 m/s) |
| Injection | Self-Calibrating Pressure-Based Injection |
| Buffer Management | Offline Buffer Replenishment System |
| Optical Path Enhancement | Extended-Path Capillary Technology |
| Detector Compatibility | DAD, LIF, MS |
| CE-MS Coupling | Single-Supplier Integrated Interface |
| Fraction Collection | Yes |
| CE-CGC Compatibility | Yes |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 7100 |
| Instrument Category | Capillary Electrochromatography (CEC) |
| Sample Analysis Scope | Organic Compounds |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CE/MS |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Analysis Scope | Organic Compounds |
| Compatible Mass Spectrometers | Agilent 6100 (Single Quadrupole), 6200 (TOF), 6400 (Triple Quadrupole), 6500 (Q-TOF), ICP-MS, ICP-MS/MS |
| Ionization Sources | ESI (Standard & JetStream), APCI, APP |
| Spray Interface | Grounded-potential, Plug-and-Play Electrospray Interface with Integrated Desolvation |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Femto Pulse |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Application | Organic Analysis (Nucleic Acids) |
| Voltage | 100–240 VAC, 47–63 Hz |
| Power Consumption | 150 VA |
| Operating Temperature | 19–25 °C |
| Relative Humidity | 20–80 % |
| Dimensions (W × D × H) | 36 cm × 51 cm × 61 cm |
| Sample Throughput | Up to 288 samples per unattended run (3 × 96-well plates) |
| Sample Volume | 2 µL per injection |
| Detection Sensitivity | 50 fg/µL for nucleic acids |
| Separation Range | Up to 165 kb DNA fragments and smears |
| Run Time | ~90 minutes for full-range HMW DNA analysis |
| Reagent Kit Type | Quantitative Analysis Kits |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Fragment Analyzer 5200 |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic Analysis (Nucleic Acids) |
| Voltage | 100–240 VAC, 47–63 Hz |
| Power Consumption | 150 VA |
| Operating Temperature | 19–25 °C |
| Relative Humidity | 20–80 % |
| Dimensions (W × D × H) | 36 cm × 51 cm × 61 cm |
| Weight | 38.5 kg |
| Throughput | 12 samples per run |
| Capillary Array Options | Three lengths for resolution/speed optimization |
| Resolution | ≤3 bp for fragments <300 bp |
| Quality Metrics | RNA Quality Number (RQN), Genomic DNA Quality Number (GQN) |
| Automation Capacity | Up to 288 samples unattended (with three 96-well plates) |
| Reagent Stability | Room-temperature stable kits |
| Compliance Support | IQ/OQ documentation available for GMP/GLP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Fragment Analyzer 5300 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Type | Nucleic Acids (DNA, RNA, cDNA, cfDNA, gDNA, mRNA, small RNA) |
| Voltage | 100–240 VAC, 47–63 Hz |
| Power Consumption | 150 VA |
| Operating Temperature | 19–25 °C |
| Relative Humidity | 20–80 % RH |
| Dimensions (W × D × H) | 36 cm × 51 cm × 61 cm |
| Weight | 38.5 kg |
| Throughput | 48 or 96 samples per run (up to 288 samples unattended) |
| Resolution | ≤3 bp for fragments <300 bp |
| Quality Metrics | RNA Quality Number (RQN), Genomic Quality Number (GQN) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | OLIGO PRO II |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Type | Organic Analysis (Single-Stranded DNA/RNA Oligonucleotides) |
| Voltage | 100–240 VAC, 47–63 Hz |
| Power Consumption | 150 VA |
| Operating Temperature | 20–23 °C |
| Relative Humidity | 20–60 % |
| Dimensions (W × D × H) | 49 cm × 58 cm × 67 cm |
| Weight | 56 kg |
| Molecular Weight Range | Up to 60-mer (single-base resolution) |
| Capillary Array Options | 12-, 24-, or 96-capillary configurations |
| Sample Throughput | Up to 96 samples per run |
| Detection Method | Direct UV absorbance (260 nm), dye-free |
| Resolution | n−1 for ssDNA/ssRNA ≤60 nt |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ZAG |
| Instrument Type | Capillary Electrophoresis System |
| Sample Application | Organic Analysis (DNA Fragment Analysis) |
| Voltage | 100–240 VAC, 47–63 Hz |
| Power Consumption | 150 VA |
| Operating Temperature | 19–25 °C |
| Relative Humidity | 20–80 % |
| Dimensions (W × D × H) | 61 cm × 59 cm × 67 cm |
| Weight | 68 kg |
| Throughput | Up to 96 samples per run, 48 × 96-well plates per 24 h |
| Separation Time | ≤20 min per 96-well plate |
| Resolution | Reliable separation of DNA fragments differing by ≥3 bp |
| Molecular Weight Range | 35 bp – 20,000 bp (dependent on selected DNA analysis kit) |
| Software | Integrated electropherogram analysis with automated sizing, binning, and reporting |
| Kit Compatibility | Qualitative DNA analysis kits (e.g., fragment analysis, microsatellite, PCR product sizing) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Capel-205 |
| Pricing | Upon Request |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Capel 205 |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (extendable to ±30 kV) |
| Pressure Range | ±1–2000 mbar |
| Detection | UV-Vis (190–600 nm, Xenon lamp, ±1 nm accuracy) |
| Capillary Temperature Control | Liquid-cooled, -10 °C to +65 °C (±0.1 °C stability) |
| Injection Modes | Voltage, Pressure, Vacuum |
| Autosampler | 59-position, Eppendorf 2 mL vials, sealed cap removal |
| Cooling System | Integrated liquid-cooled恒温 water jacket |
| Power | 110/220 VAC, 50/60 Hz, 170 W |
| Dimensions | 470 × 530 × 410 mm |
| Weight | 30 kg |
| Software | Elforun-205 (PC-based, GLP-compliant audit trail, method library, customizable reporting, spectral scanning) |
| Brand | LUMEX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Assembly | China |
| Model | Capel-105 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Analysis | Inorganic Ions, Small Molecules, Biomolecules |
| Operating Voltage | 1–25 kV (1 kV step increment, polarity auto-switching) |
| Detection | UV Absorbance (190–380 nm) |
| Light Source | High-Intensity Deuterium Lamp |
| Injection Mode | Pressure or Electrokinetic |
| Pressure Range | 0–99 mbar (step resolution: 1 mbar) |
| Electrokinetic Injection Voltage | 1–25 kV (1 kV step) |
| Capillary Cooling | Liquid-Cooled Thermostatic System |
| Temperature Control Range | –10 °C to +30 °C (±0.1 °C stability) |
| Capillary Dimensions | 30–100 cm length × 50/75/100 µm ID |
| Current Range | 0–200 µA |
| Flushing Pressure | 0–1000 / 2000 mbar |
| Power Consumption | 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Capel-105M |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (1 kV step, polarity auto-switching) |
| Detection Wavelength | 190–400 nm |
| Light Source | High-intensity deuterium lamp |
| Pressure Range | 0–99 mbar (1 mbar step) |
| Capillary Flushing Pressure | 1000–2000 mbar (1 mbar step) |
| Capillary Dimensions | 30–120 cm length × 50 or 75 µm ID |
| Temperature Control | Water-cooled thermostating, –10 to +30 °C (±0.1 °C stability) |
| Sample Introduction | Fully automated 20-position sampler (10 inlet + 10 outlet positions), electrokinetic & pressure-driven injection |
| Current Monitoring | 0–200 µA |
| Power Supply | 110/220 VAC, 50/60 Hz, 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Software | Elforun PC-based control and data analysis suite |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | BioPhase 8800 + NFD |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Detector | Native Fluorescence Detector (NFD) |
| Sample Format | ANSI/SLAS-compliant 96-well plate |
| CE Modes Supported | CE-SDS, cIEF, CZE |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Linear Dynamic Range | >4 decades |
| Correlation Coefficient (R²) | ≥0.995 |
| Sensitivity | Sub-μg/mL for native protein detection |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX BioPhase™ 8800 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Channel Capacity | 8 parallel capillaries |
| Detection Modes | UV-Vis and Laser-Induced Fluorescence (LIF) |
| Sample Format | ANSI/SLAS-compliant 96-well plate |
| Application Focus | Biopharmaceutical characterization (mAb, bispecifics, ADCs, gene therapy vectors) |
| Sensitivity | ≤1 µg/mL (CE-SDS), linear dynamic range >4 orders of magnitude (R² > 0.995) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | C100 HT |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic Analysis |
| Voltage Range | 1–25 kV |
| Detection Modes | UV and Laser-Induced Fluorescence (LIF) |
| Injection Method | Pressure-driven |
| Pressure Range | 5–100 psi |
| Cooling System | Liquid-based Temperature Control |
| Operating Mode | Constant Current |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | CESI 8000 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Type | Organic Analysis |
| Detector Options | UV and Laser-Induced Fluorescence (LIF) |
| Operating Mode | Current-Controlled |
| Injection Method | Electrokinetic |
| Pressure Range | 5–100 psi |
| Cooling System | Liquid-Cooled Temperature Control |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Intabio ZT System |
| Instrument Type | Capillary Isoelectric Focusing (cIEF) System |
| Application Focus | Charge Variant Analysis of Monoclonal Antibodies (mAbs) and Therapeutic Proteins |
| pI Resolution | ≤ 0.02 units |
| pI Range Options | 7.3–9.1 (standard ampholyte range) |
| Detection | UV-Vis (280 nm), coupled with offline or online MS integration capability |
| Data Output | Deconvoluted mass spectra aligned to individual cIEF peaks |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | P/ACE™ MDQ Plus |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic Analysis |
| Cooling Method | Liquid Cooling |
| Detectors | UV, Laser-Induced Fluorescence (LIF), Diode Array Detector (DAD) |
| Injection Mode | Electrokinetic |
| Pressure Range | 5–100 psi |
| Temperature Control | Liquid-Cooled Capillary Thermostat |
| Vendor Type | Authorized Distributor |
| Import Status | Imported |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | PA 800 Plus |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic/Biopharmaceutical Analysis |
| Voltage Range | 1–30 kV |
| Detection Modes | UV, Laser-Induced Fluorescence (LIF), Diode Array Detection (DAD) |
| Injection Method | Electrokinetic |
| Pressure Range | –5 to 100 psi |
| Cooling System | Liquid-Cooled Thermostatic Control |
| Operating Principle | Capillary Zone Electrophoresis (CZE), Capillary Isoelectric Focusing (cIEF), Capillary Gel Electrophoresis (CGE), Micellar Electrokinetic Chromatography (MEKC) |