Carbon Dioxide Analyzer Carbon Monoxide Analyzer
Filter
Showing 61–64 of 64 results
| Brand | Junfang Lihua |
|---|---|
| Model | GXH-1052L |
| Origin | Beijing, China |
| Instrument Type | Online Gas Analyzer |
| Measured Gas | CO₂ (single-component) |
| Range | 0–500 ppm (standard), customizable up to 0–100% vol |
| Resolution | 1 ppm |
| Repeatability | ≤ ±1% FS |
| Linearity Error | ≤ ±2% FS |
| Zero Drift | ≤ ±2% FS / 8 h |
| Span Drift | ≤ ±2% FS / 8 h |
| Response Time (T₉₀) | ≤ 60 s |
| Warm-up Time | ≤ 60 min |
| Operating Humidity | ≤ 90% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Output Signal | 4–20 mA analog |
| Internal Sampling Pump | Integrated |
| Enclosure Type | Rack-mountable embedded chassis |
| Brand | Junsquare |
|---|---|
| Model | GXH-3052L |
| Instrument Type | Portable Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gas | CO₂ (single-component) |
| Measurement Range | 0–1000 ppm |
| Resolution | 1 ppm |
| Repeatability | ±1% FS |
| Linearity Error | ≤±2% FS |
| Zero Drift | ≤±2% FS |
| Span Drift | ≤±2% FS |
| Response Time (T₉₀) | ≤30 s |
| Power Supply | DC (battery-operated) |
| Compliance | Designed per GB/T 18204.2–2014, HJ 870–2017, and ISO 8573-1 for ambient and stack gas CO₂ monitoring |
| Brand | MSR (Msfang Li Hua) |
|---|---|
| Origin | Beijing, China |
| Model | GXH-1051L |
| Instrument Type | Online Gas Analyzer |
| Measured Gas | CO (Carbon Monoxide) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Range | 0–50 ppm (standard), customizable up to 0–100% vol |
| Repeatability | ≤ ±1% FS |
| Linearity Error | ≤ ±2% FS |
| Zero Drift | ≤ ±1% FS / 48 h |
| Span Drift | ≤ ±1% FS / 48 h |
| Response Time (T90) | ≤ 30 s |
| Resolution | 0.1 ppm (minimum) |
| Warm-up Time | ≤ 60 min |
| Operating Humidity | ≤ 90% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Output Signal | 4–20 mA analog |
| Sample Pump | Integrated diaphragm pump |
| Enclosure | Rack-mountable embedded chassis |
| Temperature Control | Internal thermostatic stabilization |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | 9000D |
| Price | USD 13,800 (FOB Beijing) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectroscopy |
| Gas Channels | CO, CO₂, CH₄, O₂ |
| Display | Four 3½-digit LCDs (simultaneous real-time concentration readouts) |
| Response Time | T₀–T₉₀ ≤ 15 s |
| Linearity | ≤ ±2% FS |
| Repeatability | ≤ 1% FS |
| Zero Drift | ≤ ±2% FS / 4 h |
| Operating Environment | −10 °C to +50 °C, 20–95% RH (non-condensing) |
| Power Supply | 24 V DC (internal rechargeable Li-ion battery + AC adapter) |
| Weight | 4.2 kg (portable configuration) |
| IP Rating | IP54 |