Carbon Dioxide Incubator
Filter
Showing 31–53 of 53 results
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Range | 0–50 °C (dark), 10–50 °C (with illumination) |
| CO₂ Concentration Range | 0–20% |
| Capacity | 150 L |
| External Dimensions (W×D×H) | 700×640×1480 mm |
| Internal Chamber Dimensions (W×D×H) | 500×400×750 mm |
| Illumination Intensity | 0–12,000 lx (6-level adjustable LED cold light source) |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 1500 W |
| Temperature Uniformity | Not specified |
| Humidity Control | None |
| Air Filtration | HEPA-grade filter (≥0.3 µm, 99.998% efficiency) |
| Door Design | Dual-pane tempered glass with magnetic seal and nano-material gasket |
| Safety Features | Independent over-temperature cutoff, parameter memory with power-loss recovery, P.I.D. temperature control (±0.5 °C stability), programmable multi-segment cycle controller (99 cycles × 30 segments) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 0–50 °C (dark), 10–50 °C (with illumination) |
| CO₂ Concentration Range | 0–20% |
| Chamber Capacity | 300 L |
| External Dimensions (W×D×H) | 780 × 780 × 1660 mm |
| Internal Chamber Dimensions (W×D×H) | 580 × 550 × 950 mm |
| Heating System | Independent Ni-Cr Alloy Heater |
| Cooling System | Modular Refrigeration Unit with Compressor Protection Logic |
| Air Filtration | Standard HEPA-grade Air Intake Filter (≥0.3 µm, 99.998% efficiency) |
| Humidity Control | Not equipped (reservoir-based passive humidity recovery only) |
| Display Interface | Optional Color Touchscreen or LCD Panel |
| Power Supply | AC 220 V, 50 Hz |
| Rated Input Power | 2200 W |
| Temperature Uniformity | Not specified per IEC 61000-4-2 |
| Continuous Operation Capability | ≥360 hours |
| Compliance | Designed to support GLP-compliant cell culture workflows |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 10–50°C (with illumination) |
| CO₂ Concentration Range | 0–20% |
| Capacity | 400 L |
| External Dimensions (W×D×H) | 880 × 780 × 1810 mm |
| Insulation Material | Ceramic Fiber |
| Air Filtration | HEPA-grade filter (≥0.3 µm, 99.998% efficiency) |
| Door System | Dual-pane tempered glass with magnetic seal and nano-composite gasket |
| Cooling System | Modular compressor-based refrigeration with delayed start & cycle protection |
| Humidity Control | None (reservoir-based humidity recovery design, non-regulated) |
| Lighting | Adjustable LED cold-light source (0–25,000 lx, 6-level intensity, selectable red/blue spectra) |
| Control Interface | Optional color touchscreen or LCD display |
| Compliance | Designed for GLP-aligned cell culture workflows |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 10–45 °C (unhumidified), 15–45 °C (humidified) |
| CO₂ Concentration Range | 0–20% |
| Humidity Control Range | 50–85% RH (customizable to 40–95% RH) |
| Chamber Capacity | 150 L |
| External Dimensions (W×D×H) | 605 × 625 × 1375 mm |
| Power Supply | AC 220 V, 50 Hz |
| Heating System | Independent NiCr Alloy Heater |
| Cooling System | Optimized Refrigeration Module with Compressor Protection |
| Humidification Method | Steam-Based Automatic Humidifier |
| Air Filtration | HEPA-Grade Filter (≥0.3 µm, 99.998% efficiency) |
| UV Sterilization | Ozone-Free UV Lamp (mounted on ceiling) |
| Control Interface | Optional LCD or Full-Color Touchscreen |
| Programmability | 99-Cycle, 30-Stage Multi-Step Controller |
| Data Logging | USB/RS485 Interface (optional) |
| Safety Features | Dual-Limit Temperature Protection, Power-Failure Recovery, Auto-Defrost, Door-Open Recovery (CO₂ ≤3 min, Temp ≤8 min) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 0–65 °C |
| CO₂ Concentration Range | 0–20% |
| Chamber Capacity | 250 L |
| External Dimensions (W×D×H) | 580 × 500 × 850 mm |
| Internal Chamber Dimensions (W×D×H) | 580 × 500 × 850 mm |
| Air Filtration | HEPA-grade filter (≥0.3 µm, 99.998% efficiency) |
| Door Design | Dual-pane tempered glass with magnetic seal and nano-material gasket |
| Cooling System | Modular compressor-based refrigeration with auto-defrost |
| Humidity Control | None (non-humidified configuration) |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 1250 W |
| Temperature Uniformity | Not specified |
| Temperature Recovery | ≤8 min to 37 °C after 30-sec door opening |
| CO₂ Recovery | ≤3 min to 5% setpoint after 30-sec door opening |
| UV Sterilization | Ozone-free UV lamp integrated in chamber ceiling |
| Control Interface | Optional LCD or full-color touchscreen (DCP-series variant) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Range | 15–45 °C (with humidity), 10–45 °C (without humidity) |
| CO₂ Concentration Range | 0–20% |
| Humidity Range | 50–85% RH (customizable to 40–95% RH) |
| Chamber Capacity | 300 L |
| External Dimensions (W×D×H) | 710 × 765 × 1655 mm |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 1250 W |
| Temperature Uniformity | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Humidity Accuracy | ±3–5% RH |
| Air Filtration | HEPA-grade filter (≥0.3 µm, 99.998% efficiency) |
| Recovery Time | <8 min to 37 °C, <3 min to 5% CO₂ after 30-sec door opening |
| Continuous Operation | ≥360 h |
| Control Interface | Color TFT touchscreen (DCP-series variant) |
| Safety Features | Independent over-temperature cut-off, power-failure memory, audible/visual alarm |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 10–50 °C (with illumination), 0–60 °C (without illumination) |
| Temperature Uniformity | Not specified |
| CO₂ Concentration Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Range & Accuracy | 50–95% RH, ±3% RH |
| Chamber Volume | 300 L |
| External Dimensions (W×D×H) | 580 × 500 × 850 mm |
| Control Modes | Constant, Day/Night Cycling, Programmable Ramp-Soak Profiles |
| Optional Features | 90 °C High-Humidity Sterilization, UV Germicidal Lamp (Ozone-Free), Reversible Door Hinge, RS485 Communication Interface, Data Logging |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 10–50 °C (with illumination), 0–60 °C (without illumination) |
| Temperature Uniformity | Not specified |
| CO₂ Concentration Control Range | 0–20% vol |
| Humidity Control Range | 50–95% RH |
| Humidity Accuracy | ±3–5% RH |
| Chamber Capacity | 400 L |
| External Dimensions (W×D×H) | 680 × 550 × 1050 mm |
| Heating Method | Water-jacketed |
| Humidification Method | Reservoir-based natural evaporation |
| Sterilization Options | Optional 90 °C moist-heat cycle and ozone-free UV lamp |
| Lighting | Adjustable white-light illumination (0–25,000 lx) |
| Control System | Microprocessor-based with programmable day/night cycles, timer modes (run time, constant-temp time, constant-humidity time), and environmental compensation algorithms |
| Safety Features | Low-water-level cutoff, door-heating anti-condensation, independent over-temperature protection, power-failure memory, and real-time alarm logging |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 0–65 °C |
| CO₂ Concentration Range | 0–20% |
| Chamber Capacity | 150 L |
| External Dimensions (W×D×H) | 605 × 625 × 1375 mm |
| Internal Dimensions (W×D×H) | 480 × 400 × 780 mm |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 900 W |
| Temperature Uniformity | Not specified |
| Humidity Control | None |
| Display Interface | LCD or optional color touchscreen |
| Air Filtration | HEPA-grade filter (≥0.3 µm, 99.998% efficiency) |
| Recovery Time (CO₂) | <3 min to 5% setpoint after 30-sec door opening |
| Recovery Time (Temp) | <8 min to 37 °C after 30-sec door opening |
| Continuous Operation | ≥360 hours |
| UV Sterilization | Ozone-free internal UV lamp |
| Safety Features | Over-temperature alarm, power-loss data retention, compressor protection logic, auto-defrost |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 0–65 °C |
| CO₂ Concentration Range | 0–20% |
| Chamber Capacity | 300 L |
| External Dimensions (W×D×H) | 710 × 765 × 1655 mm |
| Interior Dimensions (W×D×H) | 580 × 540 × 950 mm |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 1250 W |
| Temperature Uniformity | Not specified |
| Humidity Control | None (uncontrolled) |
| Standard Filtration | HEPA-grade air filter (≥0.3 µm, 99.998% efficiency) |
| Recovery Time (CO₂) | <3 min after 30-s door opening |
| Recovery Time (Temp) | <8 min to 37 °C after 30-s door opening |
| Safety Features | Dual-limit temperature protection, auto-restart after power failure, programmable alarm thresholds |
| Optional Configurations | RS485/USB interface, side access ports (Ø25–100 mm), UV sterilization lamp, casters with locking mechanism |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 0–65 °C |
| CO₂ Concentration Range | 0–20% |
| Chamber Capacity | 500 L |
| External Dimensions (W×D×H) | 825 × 925 × 1780 mm |
| Internal Chamber Dimensions (W×D×H) | 700 × 700 × 1020 mm |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 1450 W |
| Temperature Uniformity | Not Specified |
| Humidity Control | None (Uncontrolled) |
| Standard Air Filtration | HEPA-grade filter (≥0.3 µm, 99.998% efficiency) |
| Recovery Time (CO₂) | <3 min to 5% setpoint after 30-s door opening |
| Recovery Time (Temp) | <8 min to 37 °C after 30-s door opening |
| Continuous Operation | ≥360 h |
| Safety Features | Over-temperature alarm, auto-restart after power failure, programmable temperature limits, self-diagnostic system |
| Optional Configurations | Illumination modules (red/blue LED), RS485/USB data logging, side access ports (Ø25–100 mm), UV sterilization lamp, wireless SMS alert |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 0–65 °C |
| CO₂ Concentration Range | 0–20% |
| Chamber Capacity | 800 L |
| External Dimensions (W×D×H) | 1025 × 1145 × 1800 mm |
| Internal Chamber Dimensions (W×D×H) | 900 × 850 × 1050 mm |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 2500 W |
| Temperature Uniformity | Not specified |
| Humidity Control | None (uncontrolled) |
| Air Filtration | HEPA-grade filter (≥0.3 µm, 99.998% efficiency) |
| Recovery Time (CO₂) | <3 min to 5% setpoint after 30-sec door opening |
| Recovery Time (Temp) | <8 min to 37 °C after 30-sec door opening |
| Safety Features | Over-temperature cutoff, power-loss data retention, programmable alarm thresholds, P.I.D. temperature control |
| Optional Configurations | Illumination (LED, 0–30,000 lx, multi-level), programmable diurnal cycles (RQ series), integrated USB/RS485 interface, side access ports (25–100 mm), UV sterilization lamp (ozone-free) |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MCP-170 |
| Temperature Range & Accuracy | +3 to 55 °C (±0.1 °C setpoint stability) |
| Temperature Uniformity | ≤ ±0.3 °C (at 37 °C, measured at 9 points per IEC 61000-4-2 compliant validation protocol) |
| Humidity Range & Control | 91–94% RH (with active humidity recovery <15 min after door opening) |
| Chamber Capacity | 170 L |
| Sterilization Method | 180 °C dry-heat chamber sterilization |
| Chamber Material | Electropolished 316L stainless steel interior |
| CO₂ Control | NDIR sensor with ±0.1% CO₂ accuracy, 0–20% range, PID-controlled gas injection |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DynaCell190i |
| Price Range | USD 7,800–10,000 (FOB) |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +5°C to 50°C, ±0.1°C (at setpoint) |
| Temperature Uniformity | ±0.3°C at 37°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol., ±0.1% (full scale) |
| Humidity Control Range & Accuracy | 20–95% RH, ±3% RH (measured at 37°C, 5% CO₂) |
| Chamber Capacity | 190 L |
| External Dimensions (W×D×H) | 720 × 694.5 × 890 mm |
| Standard Configuration | Dual-stage HEPA filtration (0.3 µm, ≥99.97% efficiency), Dual sterilization protocol (180°C dry-heat bake-out, 90°C moist-heat cycle) |
| Brand | Herrytech |
|---|---|
| Origin | Shanghai, China |
| Model | YQ-80A-III |
| CO₂ Detection | Infrared (IR) |
| Temperature Control Range & Accuracy | Ambient +5°C to 65°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% |
| Humidity Control | >95% RH (at stable 37°C operation) |
| Chamber Capacity | 80 L |
| Internal Dimensions | 400 × 400 × 500 mm (W × D × H) |
| Standard Configuration | Imported infrared microcomputer CO₂-specific concentration probe |
| Brand | JTONE |
|---|---|
| Origin | Anhui, China |
| Model | HH.CP-TW |
| Capacity | 160 L |
| Temperature Range | RT+5°C to 50°C |
| Temperature Uniformity | ±0.3°C |
| Refrigerant | Eco-friendly non-CFC |
| Construction | Cold-rolled steel exterior with electrostatic powder coating |
| Airflow System | Vertical laminar airflow with forced convection circulation |
| CO₂ Control | Dual-stage infrared (IR) sensor-based regulation (5% setpoint typical) |
| Humidity Control | Passive water-jacket-assisted humidification (95% RH typical at 37°C) |
| Safety Features | Independent over-temperature cutoff, UV sterilization lamp, door-temperature compensation, microbial inlet filter (0.2 µm), optional CO₂ pressure regulator |
| Compliance | Designed to support GLP-compliant cell culture workflows |
| Software Interface | LCD microprocessor controller with real-time display of temperature, CO₂ concentration, and elapsed time |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JTSQ-50A |
| Capacity | 50 L |
| Temperature Control Range | RT+5°C to 60°C |
| Temperature Uniformity | ±0.3°C |
| Humidity Range | 35% ±5% RH (natural evaporation) |
| CO₂ Control Range | 0–20.0% (IR sensor, ±0.2% accuracy) |
| O₂ Control Range | 1.0–19.0% (hypoxic) or 23.0–50.0% (hyperoxic), up to 90.0% optional |
| O₂ Sensor | Imported zirconia |
| CO₂ Sensor | Imported NDIR infrared |
| Temperature Sensor | PT100 |
| Control System | PLC-based with 4.3″ capacitive touchscreen |
| Sterilization | UV lamp (optional 90°C moist-heat or 180°C dry-heat) |
| Heating Method | Air-jacketed |
| Internal Dimensions (W×D×H) | 340 × 340 × 450 mm |
| Standard Shelving | 2 stainless steel shelves |
| Power Consumption | 250 VA (±10%) |
| Brand | NUAIRE |
|---|---|
| Origin | USA |
| Model | NU-5800 Series |
| Temperature Range & Accuracy | Ambient to 55°C |
| Temperature Uniformity | ±0.35°C |
| Humidity Range & Accuracy | 5–90% RH |
| Capacity | 235 L (not lbs — corrected per industry standard |
| Chamber Construction | Seamless 304 stainless steel interior |
| Humidity Recovery | ≤15 min (from door opening) |
| CO₂ Control | IR sensor, 0–20% range, ±0.1% accuracy |
| Sterilization Options | Integrated dry-heat (180°C) and steam-humidity (≥90°C, 95% RH) cycles |
| Filtration | Dual-stage HEPA (99.99% @ 0.3 µm) recirculating air system |
| Compliance | FDA-listed device, ISO 13485-manufactured, CE-marked, compliant with ISO 5, USP <797>, and GLP/GMP environmental monitoring requirements |
| Brand | PHCbi |
|---|---|
| Origin | Japan |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Dual-channel Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT +5°C to 50°C, ±0.1°C |
| Temperature Uniformity | ±0.25°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.15% vol |
| Humidity Control | 95% RH (±5% RH, natural evaporation via humidification pan) |
| Chamber Capacity | 170 L |
| External Dimensions (W×D×H) | 620 × 730 × 905 mm (MCO-170AICL / MCO-170AICUVHL) or 620 × 755 × 905 mm (MCO-170AICUVL) |
| Key Configurations | SafeCell UV Sterilization System, H₂O₂ Decontamination Module with Generator & Reagent, Password-protected Electronic Outer Door Lock, Independent Inner Door Kit, CO₂ Pressure Regulator, Automatic CO₂ Cylinder Switching System, Standard Gas Auto-Calibration Kit, Copper-Alloy Stainless Steel Shelving & Half-Width Dividers, Stackable Mounting Brackets, Castor Base |
| Brand | PHCbi |
|---|---|
| Origin | Japan |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Dual Infrared (IR) Sensors |
| Temperature Control Range & Accuracy | RT+5°C to 50°C, ±0.1°C |
| Temperature Uniformity | ±0.25°C |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.15% |
| Humidity Control | 95% RH ±5% RH (Natural Evaporation via Humidification Pan) |
| Chamber Capacity | 230 L |
| External Dimensions (W×D×H) | 770 × 730 × 905 mm |
| Standard Configuration | SafeCell UV Sterilization System, H₂O₂ Decontamination Plate, Password-Protected Electronic Door Lock, Integrated H₂O₂ Generator & Reagent Kit, CO₂ Pressure Regulator, Automatic CO₂ Cylinder Switching System, Standard Gas Auto-Calibration Kit, Copper-Alloy Stainless Steel Shelving, Copper-Alloy Stainless Steel Half-Width Partition, Stackable Mounting Brackets, Castor-Mounted Base |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MG-1300M-2A |
| Price Range | USD 14,000 – 70,000 (FOB) |
| Temperature Control Range & Accuracy | +5°C above ambient to +40°C, ±0.5°C uniformity in chamber, ±0.2°C in culture vessel (at +37°C, 5% CO₂, 25°C ambient) |
| Humidity Control | Not equipped |
| Capacity | Two 40-layer multilayer cell culture vessels (e.g., CellMASSter, Cell Factory, CellSTACK) |
| Heating Method | Quadruple-wall air-jacketed + inline gas stream heating |
| CO₂ Sensor | NDIR infrared (IR) type, control range 3.0–8.0%, resolution 0.1% |
| O₂ Sensor | Zirconia-based electrochemical sensor, display range 1–25% |
| Gas Flow | 2 L/min × 2 independent channels |
| Air Circulation | Horizontal laminar flow fan |
| Data Logging | Built-in Windows XP PC with 6.5" touchscreen, CSV/TXT export |
| Safety Features | Dual-stage overtemperature protection (electronic + liquid-expansion mechanical), controller fault alarm (audible), door-open interlock |
| Construction | Interior and exterior stainless steel (SUS304) |
| Dimensions (W×D×H) | 1280 × 950 × 1930 mm (excluding protrusions) |
| Standard Accessories | Two motorized rotating platforms for 40-layer vessels (incl. leveling mechanism and transport cart), one shelf for 10-layer vessels |
| Compliance | Designed for GLP-compliant bioprocess environments |
| Brand | Yi Heng (Shanghai) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BPH Series |
| Temperature Control Range & Accuracy | RT+5°C to 80°C |
| Temperature Uniformity | ±1.5°C (at 37°C test point) |
| Temperature Resolution / Stability | 0.1°C / ±0.2°C |
| Power Supply | AC 220 V, 50 Hz |
| Operating Ambient Temperature | +5°C to +35°C |
| Standard Shelving | 2 adjustable stainless-steel shelves |
| Brand | Zhongke Duling (Duling) |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MCP-170H |
| Temperature Control Range & Accuracy | +3°C to 55°C, <±0.1°C |
| Temperature Uniformity | ≤±0.3°C |
| Humidity Control Range & Accuracy | 91–94% RH |
| Chamber Volume | 170 L |
| CO₂ Concentration Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Heating Method | Direct-heating Air-jacketed |
| Humidification | Integrated 3-L Water Reservoir |
| Sterilization | 180°C Dry-Heat |
| Max Power Consumption | 1100 W |
| Interior Material | Electropolished Stainless Steel |
| Standard Shelves | 3 (max. 7 optional) |
| Shelf Load Capacity | 12 kg per shelf |
| Alarm Functions | Ambient Temp, Chamber Temp, CO₂ Level, Water Level |